FedBizOpps Amendment to a Previous Combined Solicitation
CLASSIFICATION CODE
SUBJECT
CONTRACTING OFFICE'S
ZIP-CODE
SOLICITATION NUMBER
BASE NOTICE TYPE
RESPONSE DATE (MM-DD-YYYY)
ARCHIVE
DAYS AFTER THE RESPONSE DATE
RECOVERY ACT FUNDS
SET-ASIDE
NAICS CODE
CONTRACTING OFFICE
ADDRESS
POINT OF CONTACT
(POC Information Automatically Filled from User Profile Unless Entered)
DESCRIPTION
See Attachment
AGENCY'S URL
URL DESCRIPTION
AGENCY CONTACT'S EMAIL
ADDRESS
EMAIL DESCRIPTION
ADDRESS
POSTAL CODE
COUNTRY
ADDITIONAL INFORMATION
GENERAL INFORMATION
PLACE OF PERFORMANCE
* = Required Field FedBizOpps Amendment to a Previous Combined Solicitation Rev. March 2010 Motion Camera and Data Collection system Amendment 1 15212-5319 36C24E18Q9553 09-10-2018 N 334516 US Department of Veterans Affairs Veterans Health Administration Service Area Office (SAO) East 323 North Shore Drive, Suite 500 Pittsburgh PA 15212-5319 Contracting Officer: Michael Haydo michael.haydo@va.gov michael.haydo@va.gov Questions from vendors
1. Real-time plug-in for analog data (including A/D Module), Pro Wireless eye-tracker (including 2D Gaze Module)
Question: Do you want wireless or wired? Wireless.
2. Augmented Biofeedback Module, including dynamic control of treadmill belt speed
Question: Do you want control of the Inclination also? Yes, as stated in the specs.
3. Force plates including fixed amplifiers, cables and mounting plates
Question: How many force plates? Two (2).
4. Fully Instrumented Treadmill, including Incline Feature, Safety Harness and Installation.
Question: Split belt or Single Belt? Two (2) independent running surfaces.
5. Pro Wireless 50hz eye-trackers with VR Kit (includes integration in a headset)
Question: Binocular or monocular, Wired or wireless. Wireless, as stated.
6. Camera System:
Question: Are there two rooms or one room? Twenty cameras in one room.
7. Question: Is the treadmill within a lab and the cameras to see both a gait walk way with the force plates and also the treadmill area? Yes, the treadmill will be located in a lab and the cameras should see both a gait walkway with the force plates and the treadmill area.
8. EMG system (including EMG Module)
Questions: Wireless or wired, 8 channels, 12 channel or 16 channels? Wireless. 16 EMG Signal Channels.
9. Question: What is the timeline for installation? 90 Days ARO, but that can be adjusted for lead time.