This is a detailed floor plan and specifications document for modular wall systems to be installed on the 2nd floor of the Malcolm Randal VA Hospital Administration Building in Gainesville, FL. The document includes both architectural drawings and technical requirements.

The specifications call for 333 linear feet of 9'-0" high modular walls with various configurations including painted walls, floor-to-ceiling glass with partial 3M film, and specialized areas with recessed TVs and whiteboards. The plan details multiple room types including offices, conference rooms, open office areas, and support spaces. Technical requirements specify electrical and data provisions, hardware requirements, and multiple door types including pivot doors, barn doors, and glass doors with partial 3M film treatments. The document provides detailed specifications for power/data levels, device boxes, conduit types, wire specifications, and faceplate styles. Project identification numbers indicate this is drawing ID.112 for building #573-360.

View the file

Other files for this federal contract opportunity

Other files attached to 7110--Building Modular Wall, newest first.
File Type Posted
36C24825Q0276 0002.docx DOCX document
36C24825Q0276 0001.docx DOCX document
Delivery Map.pdf PDF
36C24825Q0276.docx DOCX document
1D110 FIRST FLOOR MODULAR WALL ELEVATIONS.pdf PDF
1D109 FIRST FLOOR MODULAR WALL PLAN.pdf PDF
ID113 SECOND FLOOR MODULAR WALL ELEVATIONS.pdf PDF
FIRST FLOOR REFLECTIVE CEILING PLAN.pdf PDF
ID114 SECOND FLOOR MODULAR WALL ELEVATIONS.pdf PDF
ID111 FIRST FLOOR MODULAR WALL ELEVATIONS.pdf PDF
FIRST AND SECOND FLOOR ELECTRICAL.pdf PDF
ID115 SECOND FLOOR MODULAR WALL ELEVATIONS.pdf PDF
SECOND FLOOR REFLECTIVE CEILING PLAN.pdf PDF
Show all 13

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

PROJECT DETAILS/NOTES:

FRAME AND TRIM DETAILS

EXTRUSION PROFILE / WALL TYPE: FRAME FINISH:

□ CURVILINEAR □ ANODIZED ALUMINUM

□ RECTILINEAR □POWDER-COATED

□ BLADE □ VENEER

□ EVIL TWIN

□ INSPIRE

BASE TRIM COLOR: PVC/GLASS WIPE COLOR:

□ SILVER □ SILVER

□ CHARCOAL □ CHARCOAL

□ BLACK □BLACK

REVEAL: COPLANAR:

□ CLASSIC □ NO

□ ENZO □ YES

FLOOR, CEILING, AND SEISMIC DETAILS

FLOOR TYPE: WALL HEIGHT: 9'-0"

□ CARPET LINEAR FEET: 333

HARD SURFACE

CEILING TYPE: GRID TYPE:

□DRYWALL BULKHEAD □ 9/16" □ 15/16"

□CORNICE RAIL TILE TYPE:

□LOW WALL □FLUSH

□GRID □CONCEALED

□TEGULAR

SEISMIC REQUIRED: HARDWARE REQUIREMENTS:

□NO

□ YES

DOORS:

REFERENCE DOOR SCHEDULE FOR FURTHER DETAILS

ELECTRICAL PROVISION REQUIRED - SEE ELECTRICAL SHOP DRAWINGS

DATA PROVISION REQUIRED - SEE PON SHOP DRAWINGS

CASEWORK PROVISIONS REQUIRED - SEE CASEWORK SHOP DRAWINGS

ADDITIONAL NOTES:

SPECIAL INSTRUCTIONS:

Device Box and Faceplate Family: Mixed (see plan) Conventional Modular Wall Power

Type of Electrical Required: Mixed (see plan) Power Data (Phone) Light Switch Box Junction Box Wall Sconce Box

Receptacle Faceplate Style: Mixed (see plan) Standard Style Decorator style

Light Switch Faceplate Style: Mixed (see plan) Standard Style Decorator style

Faceplate / Trim ring Color: Mixed (see plan) Black Gray White Ivory Almond Stainless Steel Other

Power/Data Level: Mixed (see plan) Level 1 (pre-cut tile, device box, trim rings and faceplates) Level 2 (Level 1 + 3/4" empty EMT for data) Level 3 (Level 1+ pre-wired devices, AC90 flex cable (3 12 gauge wires

+ bare ground) with a pigtail end, 3/4" empty EMT for Data) (single circuit per device box unless specified in Special Electrical Instructions)

Level 4 (Level 1+ pre-wired devices, 1/2" - 8 wire power with a whip extension and a quick-connect end, 3/4" empty EMT for data)

Light Switch Level: Mixed (see plan) Level 1 (pre-cut tile, device box, trim rings and faceplates) Level 2 (Level 1 +1/2" empty aluminum flex conduit)

Pre-cut tile only for: Mixed (see plan) Power Data Light Switch Box Junction Box Wall Sconce Box Other Size

Feeds from: Mixed (see plan) Floor Ceiling Wall

Aluminum Flex / AC90 extends how far beyond top/bottom of panel (10 ft default):

EMT (Electrical Metallic Tubing) extends how far beyond top of panel? (6" to 8" default):

(NOTE: Always 1/2" below frame for base feeds)

Data Face Plates:

Conventional family

Decorator Style

DIRTT Power family Decora cat# DE301 cat# NO309 cat# HBL317 cat# AMP303 cat# AM313 cat# OR306 cat# PA308 cat# SI305 cat# SI315 TL318 TL319 cat# KR314 cat# MT316 cat# LT309 cat# NV304 PA321 DAV326 DAV324 DAV325 OR322 IN323 Other Mixed (see plan)

EXCEPTIONS:

Wire Specification (12 gauge default): Mixed (see plan) 10 gauge Other

Power Conduit Type (1/2" ID Aluminum Flex default): Mixed (see plan) 1/2" ID EMT 3/4" ID EMT None

Light Switch Conduit Type (1/2" ID Aluminum Flex default): Mixed (see plan) 1/2" ID EMT 3/4" ID EMT None

Data Conduit Type (3/4" ID EMT default): Mixed (see plan) 1/2" ID EMT None

ELECTRICAL / DATA

UP

UP

UP

UP

TOUCHDOWN SPACE

2-100

STAIR B

2-108

WOMEN

2-104

OIT IT

2-115

WOMEN

2-112

MEN

2-113

VESTIBULE

2-114

CORRIDOR

2-116

STAIR A

2-118

MEN

2-105

BREAK ROOM

2-117

STORAGE

2-109

ELEC ROOM

2-107NURSING

2-106

MECHANICAL

2-102

CORRIDOR

2-103

TRAINING

2-110

NORTH BRIDGE

2-119

SOUTH BRIDGE

2-120

CONFERENCE ROOM

2-143

CONFERENCE ROOM

2-144

FILE / COPY / STORAGE

2-145

OFFICE

2-146

OFFICE

2-147

OFFICE

2-148 OFFICE

2-149

OFFICE

2-150

OFFICE

2-151

OFFICE

2-152

OFFICE

2-153

CONFERENCE ROOM

2-142

OPEN OFFICE

2-101

REF

CORRIDOR

2-154

CORRIDOR

2-155

F2010

REF

MODULAR WALL

TYPE; GRAPHIC WALL

PIVOT DOOR - GLASS

PARTIAL 3M FILM

@72"AFF

MODULAR WALL

TYPE; OPERABLE WALL

MODULAR WALLS

TYPE; FLOOR TO CEILING GLASS

WITH PARTIAL 3M FILM

SINGLE BARN DOOR - GLASS

PARTIAL 3M FILM

MODULAR WALL

TYPE; PAINTED

MODULAR WALL -

PAINTED

DOUBLE BARN DOOR - GLASS

PARTIAL 3M FILM

MODULAR WALLS

TYPE; FLOOR TO CEILING GLASS

WITH PARTIAL 3M FILM

MODULAR WALLS

TYPE; FLOOR TO CEILING GLASS

WITH PARTIAL 3M FILM

MODULAR WALL

TYPE; PAINTED, WITH RECESSED TV,

AND WHITEBOARDS

MODULAR WALL

TYPE; PAINTED, WITH RECESSED TV,

AND WHITEBOARDS

MODULAR WALL

TYPE; PAINTED, WITH RECESSED TV,

AND WHITEBOARDS

DOUBLE BARN DOOR - GLASS

PARTIAL 3M FILM

DOUBLE BARN DOOR - GLASS

PARTIAL 3M FILM

@72"AFF @72"AFF

PIVOT DOOR - GLASS

PARTIAL 3M FILM

MODULAR WALL

TYPE; PAINTED

MODULAR WALL

TYPE; PAINTED

MODULAR WALL

TYPE; PAINTED

SINGLE BARN DOOR - GLASS

PARTIAL 3M FILM

SINGLE BARN DOOR - GLASS

PARTIAL 3M FILM

SINGLE BARN DOOR - GLASS

PARTIAL 3M FILM

SINGLE BARN DOOR - GLASS

PARTIAL 3M FILM

SINGLE BARN DOOR - GLASS

PARTIAL 3M FILM

SINGLE BARN DOOR - GLASS

PARTIAL 3M FILM

SINGLE BARN DOOR

GLASS PARTIAL 3M FILM

MODULAR WALLS

TYPE; FLOOR TO CEILING GLASS

WITH PARTIAL 3M FILM

MODULAR WALLS

TYPE; FLOOR TO CEILING GLASS

WITH PARTIAL 3M FILM

MODULAR WALL

TYPE; PAINTED

MODULAR WALL

TYPE; PAINTED

MODULAR WALL

TYPE; PAINTED

MODULAR WALLS

TYPE; FLOOR TO CEILING GLASS

WITH PARTIAL 3M FILM

DOUBLE BARN DOOR - GLASS

PARTIAL 3M FILM

MODULAR WALLS

TYPE; FLOOR TO CEILING GLASS

WITH PARTIAL 3M FILM

8C

ID113

8AID113 8B ID113 8E ID113

9AID113

ID114

12BID115

13 ID115

8D

ID113

8FID113 8G ID113

9B ID113

10BID114 10C ID114 10DID114 10FID114 10HID11410E ID114 10G ID114 10I ID114

10K

ID114

12A

ID114

12C ID115 12DID115 12FID115 12HID11512E ID115 12G ID115 12I ID115

10A

ID114

MALCOM RANDAL VA HOSPITAL

ADMINISTRATION BUILDING

Drawing Title

Approved: Project Director

Project Title

Date

Location

Checked

Building Number

Project Number

Drawing Number

Drawn

Dwg 1 ofRevisions: Date

CONSULTANTS: ARCHITECT/ENGINEERS: Office of Construction and Facilities Management xxxx -xxxx

VAWPBMC PLANNING AND ENGINEERING

FLGAINESVILLE-

BLDG #

573-360 on e ei gh th i nc h on e fo ot 16

B

A

C

D

E

F th re e in ch es o ne f oo t on e a nd o ne h a lf i nc he s on e fo ot on e in ch o ne f oo t th re e qu a rt er s in ch o ne f oo t on e ha lf i nc h on e fo ot th re e ei gh th s in ch o ne f oo t on e qu a rt er i nc h on e fo ot

VA FORM 08-6231

1 2 3 4 5 6 87 9

F

E

D

C

B

A

1 2 3 4 5 6 87 9

12/09/2024 AGR AGR 5

GNV Admin Building, 2nd Floor Modular Plan

4/

/2

1:

:5

PM

C :\U se rs

\d sa ng _0

\A

D C

D ro pb ox

\A D

M

IN

G ai ne sv ille

\V A

Ad m in \0 pr oj ec t C

AD

\R ev it to

T

LC

1.

.2

3\ Ad m in

R ev

1.

.2

3.

rv t

ID.112NO. DESCRIPTION DATE

A Revision Description Revision Date

AutoCAD SHX Text

NOTES

AutoCAD SHX Text 1.) VENDOR IS RESPONSIBLE FOR CONFIRMING ALL FIELD DIMENSIONS, AND WALL UTILITIES FOR COORDINATION WITH WALLS, AND FURNITURE. 2.) PLANS ARE FOR GRAPHIC REPRESENTATION ONLY, VENDOR IS RESPONSIBLE FOR ALL VERIFICATION OF EXISTING SITE CONDITIONS.

AutoCAD SHX Text

LEGEND

AutoCAD SHX Text

SOLID LINE; GLASS WITH

AutoCAD SHX Text

NO FILL; PAINTED WITH

AutoCAD SHX Text

DOUBLE DASHED; OPERABLE

AutoCAD SHX Text

SINGLE DASHED; GRAPHIC

AutoCAD SHX Text

WALL TYPE

AutoCAD SHX Text

RECESSED TV & WHITE-

AutoCAD SHX Text

WALL TYPE

AutoCAD SHX Text

LONG DASHED;

AutoCAD SHX Text

PAINTED WALL TYPE

AutoCAD SHX Text

BOARDS WALL TYPE

AutoCAD SHX Text

3M FILM WALL TYPE

Sheets and Views
ID112

File details come from the government source that posted it. Updated .