36C24819Q0384-001.pdf

PDF 390 KB Posted

Attached to
Modular Wall System Federal contract opportunity
Solicitation number
36C24819Q0384
Issued by
Department of Veterans Affairs Veterans Health Administration Veterans Integrated Service Network 8

About this file

36C24819Q0384 Attachment A Salient Characteristics.pdf

View the file

Other files for this federal contract opportunity

Other files attached to Modular Wall System, newest first.
File Type Posted
36C24819Q0384-0001000.docx DOCX document
36C24819Q0384-0001001.pdf PDF
36C24819Q0384-003.pdf PDF
36C24819Q0384-000.docx DOCX document
36C24819Q0384-002.pdf PDF

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Attachment A

Salient Characteristics

Brand Name or Equal

BAY PINES VAMC

10000 Bay Pines Blvd, Building 108

Bay Pines, FL. 33744

Nurse Stations & Check‐In

***NOTE: Due to Building 108 construction, furniture shall not be deliver/installed until 4th

Quarter 2019. Scheduling shall be coordinated with the Contracting Officer after award of the contract.

1. Modular Partitions

DIRTT or Equal

Quantity: Two Nurse Stations in Infusion Area and One Check‐in Station in Main Lobby

SECTION 1 ‐ MODULAR PARTITIONS

Part 1 General

1.1 SUMMARY

.1 Section includes:

.1 Modular partitions framing;

.2 Face tiles;

.3 Glass and glazing;

.4 Doors and door hardware;

.5 Accessories.

.6 Finishes.

.2 Related Sections:

.1 064017 ‐ Modular Architectural Woodwork.

.2 260517 ‐ Electrical Systems for Modular Partitions.

.3 Base Building Documents:

.1 Division 06 Architectural Woodwork.

.2 Division 08 Doors and Door Hardware.

.3 Division 09 Finishes.

.4 Division 26 Electrical.

.5 Division 27 Communications.

.6 Division 28 Electronic Safety and Security

1.2 REFERENCES

.1 American Architectural Manufacturers Association (AAMA):

.1 AAMA 61198 Voluntary Standards for Anodized Architectural Aluminum.

.2 American Society of Civil Engineers (ASCE):

.1 ASCE‐7 Minimum Design Loads for Buildings and Other Structures.

.3 ASTM International:

.1 ASTM E72 Method for Conducting Strength Tests of Panels for Building Construction.

.2 ASTM E84 Test Method for Surface Burning Characteristics of Building Materials.

.3 ASTM E90 Method for Laboratory Measurement of Airborne Sound Transmission Loss of Building Partitions and Elements.

.4 ASTM E413 Classification for Rating Sound Insulation.

.4 CAN/ULC‐S102 Standard Method of Test for Surface Burning Characteristics of Building Materials and Assemblies.

1.3 PERFORMANCE REQUIREMENTS

.1 Structural Performance: Modular partitions shall be capable of withstanding the effects of gravity loads, dead loads, and the following loads and stresses within limits and under conditions indicated:

.1 Transverse Load: Lateral deflection of the overall span when tested under a uniformly distributed load of 5 psf (0.24 kN/m2) in accordance with ASTM E72 where L = modular partition wall height:

.1 Solid Walls: not more than L/120;

.2 Glass Walls: not more than L/175 or 3/4 inch (19 mm) whichever is more stringent.

.2 Mechanical Strength: Capable of withstanding static loads in accordance with ANSI/BIFMA X5.6.

.3 Seismic Performance: Provide modular partitions capable of withstanding effects of seismic motions determined according to the currently adopted building codes.

.2 Acoustical Performance: Where STC ratings are indicated, provide partitions with STC rating determined by testing an identical system to ASTM E90 and classified in accordance with ASTM E413.

.1 Sound Transmission Coefficient (STC) range shall be determined in accordance with Sound Transmission Test by Two‐Room Method and reported in accordance with ASTM E90 and ASTM E413 for frequency data. Tested assembly shall have been assembled in the same manner the modular partitions to be installed on the project.

.2 Test results vary based on glass or solid wall configuration, and implementation of perimeter enhancements at base building connections.

.1 Solid wall results range up to 50 STC performance.

.2 Glass wall performance is limited by the glass specified.

Coordinate requirements with the modular partition manufacturer.

.3 Fire Resistance:

.1 Surface‐Burning Characteristics: Tested in accordance with ASTM E84 by a qualified independent testing agency.

.2 National Building Code of Canada, CAN/ULC‐S102 Surface Burning Characteristics of Building Materials and Assemblies.

.4 Sustainable Design Requirements: Submit project specific documentation to demonstrate the following:

.1 MRc4.1 and 4.2 Recycled Content, calculated by weight:

.1 MDF Standard Tiles: 100% pre‐consumer recycled content.

.2 Aluminum: Confirm with the manufacturer plant location.

.2 MRc5 Regional Materials:

.1 LEED NC: Minimum 20%.

.2 LEED‐CI: Minimum 10% .3 MRc6 Rapidly Renewable Materials:

.1 MDF and Wood Materials;

.2 Recycled Cotton Insulation;

.3 Decorative Components;

.4 Bio‐Based Materials.

.4 IEQc4 Low Emitting Materials:

.1 IEQc4.1 Adhesives and Sealants and 4.2 Paints and Coatings:

.1 Field Applied: Documented by project contractor.

.2 Factory Applied: MSDS and VOC content available upon request.

.2 IEQc4.4 Composite Wood and Laminate Adhesives:

.1 MDF Tiles: California Air Resources Board (CARB) 2 Certified.

.3 IEQc4.5 Systems Furniture and Seating:

.1 SCS Indoor Advantage Gold Certification:

.1 SCS‐IAQ‐02433: Chromacoate on MDF.

.2 SCS‐IAQ‐02433: Glass and aluminum walls.

.3 SCS‐IAQ‐02873: Thermofoil on standard MDF.

.5 IEQc8.1 Daylight and Views.

.6 IEQc8.1 Daylight.

.7 Innovation in Design (ID).

.8 Pilot Credits:

.1 Life Cycle Assessment (LCA);

.2 Environmental Product Declaration (EPD);

.3 Health Product Declaration (HPD);

.4 Life Cycle Impact Reduction.

.5 Acoustic Measures.

.6 Lead Free Content including conduit: maximum 40ppm.

.5 Coordination Requirements:

.1 Comply with Division 01 project management and procedures.

.2 Project Scheduling and Lead Times: Manufacturing production time of all standard products and finishes shall not exceed five weeks, inclusive of shipping within US and Canada, from manufacturer’s receipt of complete order information (including shop drawing approval, deposit cost, and notice to proceed).

.1 Maximum delivery time on solutions included on GSA contracts shall not exceed 45 days. Coordinate adjacent work, including other work by others to be installed within or next to Work of this section.

.3 Schedule: Coordinate delivery with construction schedule to avoid storage or double handling of the modular partition system.

.4 Install modular partition system after the building is enclosed and conditioned including completion of HVAC equipment, fire suppression system, lighting, adjacent ceilings and base building finishes in a sequence that allows final electrical connection, voice data/communications to be completed during or after installation of the modular partition systems.

.1 Coordinate modular partition installation with ceiling, floor finish, and specified wall base (modular partition standard base, applied base, or integral base installation).

.5 Floor and base finishes may be completed before installation of modular partition system unless coordinated with the manufacturer ahead of time through the Shop Drawing process.

1.4 SUBMITTALS

.1 Product Data:

.1 Provide manufacturers standard product information for each type of product indicated.

.2 Shop Drawings:

.1 Where required by the local building authority, provide structural analysis data and calculations for installed products to demonstrate compliance with design loads, signed and sealed by licensed professional engineer registered in the jurisdiction of the project.

.2 Provide manufacturer’s architectural plans, elevations, sections, connection and attachment details, finish schedule, reflected ceiling plans, doors and hardware schedule, electrical and mechanical requirements, schedules, and locations.

.3 Provide manufacturer with product data, fabrication drawings, schematics and similar information for data, security, or communications to be embedded within or supported by modular partitions.

.4 Include field measurements of existing construction, future construction, finished width and height of partitions and associated components.

.1 Manufacturer’s authorized representative shall undertake field measurements to show relevant adjacencies in Shop Drawings.

Site conditions, base building construction, and required clearances are to be reviewed and approved by the Architect, including exiting, life safety, location of building service devices, and other affected trades through Shop Drawings to identify and prevent potential conflicts.

.2 Where field measurements are not possible, hold‐to and control dimensions must be coordinated and agreed upon by all parties through the Shop Drawing process before manufacturing begins.

.3 Coordination Drawings:

.1 Provide shop drawings for coordination between trades upon request.

.2 Provide architectural plans locating modular partitions within the base building, including finishes and construction of surfaces the modular partition system will interface with or connect to.

.3 Provide reflected ceiling plans, drawn to scale, to show penetrations and ceiling mounted items to be coordinated with modular partitions and associated system components.

.4 Structural: coordinate structural connections to base building and generate engineering calculations where required by the local building authority.

.5 Electrical: Coordinate electrical components with final circuited electrical engineering documents.

.4 Samples: Provide manufactures standard size samples for verification of support system and each type, color, and texture of exposed finish, full thickness and the following minimum sizes:

.1 Extrusion Components.

.2 Tile Finishes.

.3 Linear Trim and Base.

.4 Door Face Finishes.

.5 Glazing.

.5 Provide product data sheets for all types of Hardware and Accessories.

.6 LEED Submittals:

.1 MRc4.1 and MRc4.2 Recycled Content: Product Data and costs indicating percentages by weight of post‐consumer and pre‐consumer recycled content.

.2 MRc5.1 and MRc5.2 Regional Materials: Product Data and costs indicating percentages by weight of regional materials as defined by LEED for the project type.

.3 MRc6 Rapidly Renewable Materials: Manufacturer certificates.

.4 MRc7 Certified Wood: Manufacturer certificates.

.5 IEQc4.1 Low Emitting Materials ‐ Adhesives and Sealants: Product data for field applied adhesives including printed statement of VOC content.

.6 IEQc4.2 Low Emitting Materials ‐ Paints and Coatings: Product data for field applied paints and coatings, including printed statement of VOC content and chemical components.

.7 IEQc4.4: Product data for each composite wood product and adhesive used indicating bonding agents and adhesives contain no urea formaldehyde.

.8 IEQc4.5 Systems Furniture and Seating: Manufacturer certificates or SCS Indoor Advantage Gold Certification.

.9 IEQc8.1 Daylight and Views: Architectural and modular partition drawings and additional documentation as required by LEED

.10 IEQc8.2 Daylight: Architectural and modular partition drawings, product data, and additional documentation as required by LEED.

.11 Innovation in Design (ID): documentation as required by LEED.

.12 Pilot Credits: Provide documentation as required by LEED for the following:

.1 Life Cycle Assessment (LCA).

.2 Environmental Product Declaration (EPD).

.3 Health Product Declaration (HPD).

.4 Life Cycle Impact Reduction.

.5 Acoustic Measures.

.6 Lead Free Content.

.7 Product Test Reports, Solid Partitions: Based on evaluation of comprehensive tests performed by an independent qualified testing agency:

.1 Evaluation/Certification Reports:

.1 ICC ESR (Evaluation Service Report), ESR1947 (reissued 2007):

Provide evidence of compliance with structural performance requirements and relevant building codes.

.2 Intertek Certification demonstrating compliance with UL 1286 Office Furnishings.

.3 UL QQXX ‐ Sections and Units for electrical components.

.4 OSHPD Preapproval of Manufacturers Certification.

.5 IRR‐1012 ‐ Intertek (Warnock‐Hersey) Solid Wall Code Evaluation Report / Listing.

.8 Maintenance Data: Provide maintenance data for incorporation into operation and maintenance manuals.

1.5 QUALITY ASSURANCE

.1 Qualifications:

.1 Manufacturer Qualifications: Manufacturer shall specialize in designing and manufacturing modular partitions of the quality and complexity required for this project with a minimum of 10 years documented successful experience. Manufacturer shall have production facilities capable of meeting contract requirements for single‐source responsibilities and warranty.

.2 Installer Qualifications: Certified by the manufacturer.

.2 Certifications:

.1 Sound Transmission Characteristics: Testing to be performed by a qualified independent testing agency in accordance with performance requirements above.

.3 Pre‐Installation Conference:

.1 Meet at the project site minimum 1 week prior to Shop Drawing approval and prior to beginning installation. Meeting shall include authorized representatives of the Owner, Architect, base building contractor and all trades whose work will interface with installed systems.

1.6 DELIVERY, STORAGE AND HANDLING

.1 Do not deliver or install modular partitions until spaces are enclosed and weather‐tight, wet work is complete and dry, work above ceilings is complete, and HVAC system is operational and able to maintain ambient temperature and humidity conditions at occupancy levels for the remainder of the construction period.

.2 Ship system components in manufacturer’s standard packaging. Maintain air circulation during shipment. Do not allow packaging to get wet or develop condensation.

.3 Deliver materials to project site or offsite warehouse as directed by the Contractor or Owner as applicable, and in accordance with the manufacturer’s instructions in original unopened and undamaged packages. Packages shall be labeled with manufacturers name, brand names, size, finishes, and placement locations.

.4 Store in a clean, dry, secure space to protect from damage during construction activities. Minimize or eliminate storage period by coordinating with construction schedule.

.5 Handle in accordance with the manufacturer’s instructions.

1.7 PROJECT CONDITIONS

.1 Environmental Limitations: Do not deliver or install system and components until building is enclosed and finishing operations are complete, including adjacent ceiling and floor covering installation and painting.

.2 Temperature and humidity shall be maintained to final occupancy standards.

Installation areas shall be climate controlled between 60 and 90 degrees F (15.5 and 32.2 C) with Relative Humidity maintained between 25 and 55 percent.

1.8 WARRANTY

.1 Provide manufacturers standard, limited, transferable warranty executed in the name of the Owner. Guarantee the site assembled modular structure, panel system and components are free from defects in material and workmanship.

.1 Warranty Period, Modular Partition System: 10 year limited warranty.

Part 2 Products

2.1 MANUFACTURERS

.1 DIRTT Environmental Solutions;

.1 Website: www.dirtt.net

.2 GSA Schedule:

.1 Contract: GS 07F 0005T.

.2 CCR#: 73193726.

.2 Substitutions: Not permitted without demonstrating compliance with aesthetic effects shown in the drawings, performance requirements and lead times specified above.

2.2 SYSTEM DESCRIPTION

.1 Factory assembled, site installed, moveable, demountable, reusable interior solid and glazed partitions, including structure, face mounted finished tiles, modular and non‐modular metal framing and doors to accept a variety of millwork, finishes, building services components, technology, and accessories.

.2 System is floor‐supported, floor‐to‐ceiling site constructed in configurations shown on the Shop Drawings. Top channels hold modular partitions in place and accommodate height adjustments to suit floor‐to‐ceiling dimensional variations and similar site specific requirements.

.1 Where modular partitions are not clipped to ceilings or other overhead construction, additional structural review and system engineering will be required by the manufacturer.

.3 Panel Attachment: Unitized aluminum frame assembly to support face mounted tiles in orientation and module increments as shown on the Drawings.

.4 Partially Unitized Solid Wall system shall be comprised of modular components which can be disassembled, relocated / field cut and substantially reused.

.5 Face tiled finishes applied to lightweight frame system, may be monolithic or segmented with the ability to span off‐module, or across multiple frames in segments or monoliths, vertically and horizontally.

.6 Manufacturer shall provide integrated strategy for accommodating accessory channels and reveals integrated into the structural frame allowing universal horizontal alignment to support millwork, furniture, storage and accessories without defacing or damaging face tile or structural frame.

.1 Materials manufactured by others shall not exceed the modular partition manufacturer’s limitations or tested performance.

.7 Manufacturer shall provide accommodation / provision for the embedding of technology in the wall cavity: structural framing shall allow for universal nonstandard AV display, sound, and various support equipment to be mounted in the cavity of the wall with all required structural brackets, wire management, access and ventilation equipment to prevent overheating.

.8 Manufacturer shall provide ability for independent configuration / finish. Each side of wall must have the capability for variable aesthetic and function to suit different requirements. This will allow for the one side of the wall to have a totally independent function than the other to meet each organizations requirement.

.9 Manufacturer shall accommodate and provide provisions for additional embedded elements (ie sofas, exam tables, chaises, charting stations, and millwork) in the wall cavity as documented.

.1 Embedded elements and accessories to be provided by others may require additional engineering for structural framing and supports within modular partitions. Submit documentation of all items to be mounted to or embedded in modular partitions for manufacturer review and approval.

.2 Do not proceed with procurement or fabrication without modular partition manufacturer’s review and approval.

.10 Electrical and Communications Access: 1 inch (25 mm) to 3 inches (75 mm) clear wall cavity for accessible from either side of partition by removable face tiles.

.11 Provide back boxes, supports, and conduit as required to accommodate data, security and communications indicated on shop drawings. Modular partition manufacturer to provide continuous 1 inch (25 mm) open cavity vertically and horizontally between all frames.

.12 Modular partition manufacture shall allow for adaptability and retrofitting of hardware for future division of partitions, tiles, or supports to the greatest extent practical.

2.3 MODULAR PARTITIONS FRAMING

.1 Framing for Solid and Face Tiled Partitions:

.1 Material: Aluminum extrusions, 6063T6 aluminum alloy, thickness engineered to meet performance requirements specified above.

.2 Vertical Support Spacing: 6 inch (150 mm) minimum to 48 inch (1219

mm) maximum.

.3 Ceiling Track: Continuous, with intermittent breaks for pass through of building services or structural components.

.4 Floor Track: Modular with wall frames inclusive of carpet grippers or floor tape (non‐seismic) or continuous with floor anchor attachment (seismic) stopped at doorways and pass‐throughs.

.5 Bracing: as required to meet structural performance.

.6 Fasteners: Zinc Plated Steel Type F Screws unless otherwise indicated on engineered shop drawings.

.2 Framing for Glazed Partitions:

.1 Same as solid panel framing with customized spacing as shown on the Drawings. Maximum spacing 60 inches (1524 mm).

.3 Frame Bases:

.1 Provide frame bases with provisions for 1‐1/2 inch (38.1 mm) height adjustment to accommodate floor slab variances.

.2 Provide a leveling mechanism for making fine adjustment in height over adjustment range of the product.

2.4 FACE MOUNTED FINISHED TILES

.1 Panel Construction:

.1 Standard Solid Tile Material: Medium Density Fiber Core (MDF).

.2 Thickness:

.1 Solid Tiles: 1/2 inch (13 mm).

.2 Glass Tiles: 1/4 inch (6 mm) with aluminum mounting rails to maintain alignment with adjacent finishes.

.3 Widths: As shown on shop drawings.

.4 Height: As shown on shop drawings.

.5 Finishes: As specified below and as shown on the Drawings.

.2 Reveals:

.1 Classic: 0.35 inch (9 mm);

2.5 GLASS AND GLAZING

.1 Typical: Tempered glass minimum thickness 6 mm (1/4 inch) to ASTM C1048, Kind FT (fully tempered), Condition A (uncoated), Type 1, Class 1 (transparent), Quality q3.

.3 Specialty Glass:

.1 [Etched glass pattern “Spurt”]

.2 Specialty glass materials must be approved by manufacturer prior to procurement or fabrication.

.4 Glass Types:

.1 Glass Type : [1/4” Etched glass pattern “Spurt”]

2.6 DOORS AND DOOR HARDWARE

.1 General:

.1 Coordinate security system components to be provided by others with Modular partitions manufacturer through the Shop Drawing process.

.2 Provide uneven leaf doors as documented on Shop Drawings.

.2 Glazed Aluminum Doors: Manufacturer's standard stiles and rail door, [pivot] operation, glazed aluminum doors.

.3 Door Thickness: 1‐15/32 inches (43 mm) thick.

.4 Stile Width: [4] inches ([102]mm).

.5 Top Rail Height: [4] inches ([102] mm).

.2 Bottom Rail Height: [7‐7/8 inches (200 mm)] AFF.

.1 Provisions for ADA bottom rails as determined by the design professional of record.

.3 Adjustability: Provide door skirt to accommodate varying floor levels.

.4 Door Height: As noted on shop drawings. Maximum height 10 feet (3 meters).

.5 Glazing: [Tempered] glass, [6] mm ([1/4] inch) thick, [clear] .

.6 Hardware Reinforcement: Factory milled by modular partition manufacturer to suit glass and hardware supplied by others as shown on show drawings.

2.7 DOOR FRAMES

.1 Pivot Door Frames: Manufacturer's standard aluminum frame [single door], reversible, factory milled to receive hardware, for 1‐15/32 inches (43 mm) +/‐ 1/16inch (1.5mm) doors.

.1 Door Module Size: [40”]

.1 Finished door width is equal to module width less 2 inches (51 mm).

.2 Configuration: Header, jambs and pivot hardware. Single door frame width not to exceed 44 inch (1118 mm) wide module.

.3 Hardware Preparation and Reinforcement: Milled, reinforce, drill and tap frames at factory to receive specified hardware in accordance with the contract hardware schedule and templates.

.4 Frame Height: Jambs shipped over length (height) by 2 inches (51 mm), for field cutting to suit opening height for proper alignment with adjacent frames.

.5 Electrical Requirements:

.1 Security System Components: Coordinated hardware requirements and prep work for security system components (supplied by others including but not limited to: electronic strikes, Magnetic locks, electrified locksets, hinges, request to exit buttons, motion sensor rex, door position contacts).

.6 Factory notched and drilled jambs for ceiling track and manufacturer’s standard header attachment.

.7 Extrusion Profile: [Curvilinear] profile to match any adjacent unitized glass frames.

.8 Seals: Manufacturer's standard.

2.8 ACCESSORIES

.1 Connections and Supports: Manufacturer's standard connections and supports that connect and release from floor and ceiling without damage using carpet grippers and ceiling track clips, with exception of the following conditions:

bulkhead (drywall ceiling), seismic conditions, electrical or service feeds, physical connections to base building (where required).

.2 Panel Joint Closure: Manufacturer's standard, capable of closing up to a 25 mm (1 inch) gap between demountable partitions and base building elements.

.3 Trim: Continuous and modular, factory finished, snap on type; field cuttable for variations in floor and ceiling levels.

.1 Base Trim Profiles: Recessed; removable to access leveling mechanisms.

.2 Ceiling Trim Profile: Recessed; adjustable to accommodate up to a 12 mm (1/2 inch) gap between demountable partitions and base building elements.

.3 Wall Trim Profile: Recessed; adjustable to accommodate up to a 12 mm

(1/2 inch) up to 25 mm (1 inch) gap between demountable partitions and base building elements.

.4 Tile to Tile Profile: As detailed.

.5 Colors: As selected by Architect from manufacturer's full range.

.4 Brackets:

.1 Manufacturer's brackets, supports and accessories for complete installation of system's furniture components, architectural millwork, audio visual equipment, and paper accessories.

.2 Provide bracket design to enable other system furniture to mount to modular partitions, on or off module.

2.9 FABRICATION

.1 Modular Tiles:

.1 Unless otherwise indicated on shop drawings, factory assembled frames with 1inch (25 mm) insulation, base track and levelers; face mounted tiles installed to frames on site.

.2 Components:

.1 Fabricate components for installation with concealed fastening devices and pressure fit members that will not damage ceiling or floor coverings.

Exceptions: Drywall ceiling, seismic applications and doors against base building require screw holes in base building for proper fastening.

.2 Fabricate for installation with manufacturer’s standard seals at floor and other locations where partition assemblies abut fixed construction and for installation of sound attenuation insulation in partition cavities.

2.10 FINISHES

.1 Protect finishes on exposed surfaces from damage during shipping.

.2 Appearance of Finished Work:

.1 Finishes shall match approved samples.

.2 Variations in natural finishes such as stone and wood shall be reviewed and accepted in accordance with industry standards.

.3 Frame Finishes:

.1 Clear Anodized Aluminum: AAMA 611, AAM12C22A31, Class I.

.4 Factory Applied Panel Finishes: Make joints only where total length exceeds maximum manufactured length. Joints and reveals as indicated on approved Shop Drawings.

.1 Paint Finish (PNT):

.1 Series: [Standard].

.2 Coating Type: UV cured water based paint, Chromacoat or approved equivalent.

.3 Color: [TBD].

.2 Thermofoil Finish (THRM):

.1 Material: [GRADE 2].

.2 Color: [TBD].

.3 Solid Surface Finish (CRN):

.1 Material: Corian by Dupont or approved equivalent.

.2 Color: [______].

.5 Door Finishes:

.1 [Clear anodized aluminum; AAMA 611, AAM12C22A31, Class I]

Part 3 Execution

3.1 EXAMINATION

.1 Verify field or hold‐to control dimensions before fabrication of modular partitions. Coordinate fabrication schedule with construction schedule and progress to avoid delay in the work.

.2 Examine all adjoining work including work by others. Do not proceed with fabrication or installation until unsatisfactory conditions are corrected.

3.2 PREPARATION

.3 Locations to receive modular partitions shall be inspected for compliance with manufacturer’s requirements.

.4 Site floor conditions must be surveyed to determine the nature of floor level and determine where special conditions exist beyond manufacturer’s standard leveling capabilities of 1‐1/2 inch in 4’‐0” (38.1 mm in 1219 mm).

.5 Field conditions and pre‐existing installations by others which may adversely affect installation or exceed the manufacturer’s limitations shall be corrected before installing modular partitions.

3.3 INSTALLATION (TYPICAL PROCESS)

.1 Installation of modular partitions system shall be completed by a manufacturer certified installer.

.2 Install system level, plumb, and aligned.

.3 All building services shall be installed and connected to the base building systems by licensed sub trades. All building services shall be inspected by authorized trade representatives and Authority Having Jurisdiction in the presence of a manufacturer representative. Coordinate with all affected parties as required.

.4 Installation sequence as determined by the certified installer and coordinated with the General Contractor based on project conditions.

3.4 CLEANING

.1 Upon completion of installation, modular partition components and finishes shall be cleaned in accordance with the finish manufacturer’s instructions. Alkaline or abrasive agents shall not be used. Avoid scratching or marring finishes.

3.5 PROTECTION

.1 Protect from damage through the duration of construction activities.

3.6 DEMONSTRATION | TRAINING

.1 Refer to Division 01 “Demonstration and Training”.

.2 Manufacturer’s Distribution Partner will be responsible to provide general product training to the Owner or their outsourced operations team at time of installation as well as conduct a comprehensive training session(s) to convey the methodology, and assembly of the modular partitions to sustain general operational maintenance by the Owner’s personnel with clearance over the facilities lifetime.

.1 Reconfiguration and modifications shall comply with manufacturer’s warranty requirements. Extensive or unusual changes will require additional Shop Drawings and manufactured components.

END OF SECTION

SECTION 2‐ MODULAR ARCHITECTURAL WOODWORK

Part 4 General

4.1 SUMMARY

.1 Section includes: Modular, demountable, reusable interior millwork for surface, semi‐recessed, or embedded mounting to manufacturer’s modular partition system, or to conventional construction materials.

.1 Modular architectural woodwork;

.2 Cabinet hardware;

.3 Accessories.

.4 Finishes.

4.2 REFERENCES

.1 Architectural Woodwork Standards (AWS): a joint effort of US Architectural Woodwork Institute (AWI), Architectural Woodwork Manufacturers Association of Canada (AWMAC) and Woodwork Institute (WI).

.1 American Woodworking Standards (AWS) Manual.

4.3 PERFORMANCE REQUIREMENTS

.1 Modular architectural woodwork as installed shall meet the fabrication requirements of the Architectural Woodwork Standards (AWS) for [Premium] Grade.

.1 Premium Grade installation shall be by inconspicuous means.

.2 Incorporate systems and materials specified in other sections as indicated above and as shown on the Drawings, including but not limited to framing, glazing, electrical conduit, and extensive built in communications cabling.

.2 Modular Architectural Woodwork as installed shall be in configurations shown in the Drawings, finished on all sides that are or might be exposed without compromising structural or visual integrity.

.1 Counters, facades, partitions, doors, and shelves shall consist of 19 mm thick Medium Density Fiberboard (MDF) covered on all sides as indicated in Drawings. Sides which will remain permanently covered shall be finished.

.2 Field dimensions shall be verified prior to development of Shop Drawings.

Indicate control dimensions where future or adjacent work is not yet installed.

.3 Modular Architectural Woodwork includes cabinets, countertops, backsplashes, supports, shelving, filler panels and accessories as shown on Shop Drawings and as required for a complete installation.

.1 Concealed blocking and joint sealing to base building walls (as opposed to Modular Partitions) is provided by others.

.4 All cabinet hardware shall be provided by Modular Architectural Woodwork fabricator.

.3 Structural Performance: Modular Architectural Woodwork shall be capable of withstanding the effects of gravity loads, dead loads, and transverse loads.

.1 Seismic Performance: Provide modular architectural woodwork capable of withstanding effects of earthquake motions determined according to ASCE 7 Minimum Design Loads for Buildings and Other Structures.

.4 Acclimate Modular Architectural Woodwork to average prevailing temperatures and relative humidities indicated for each installation area, for a minimum of 72 hours, prior to installing.

.5 Coordinate delivery with construction schedule to avoid storage or double handling of Modular Architectural Woodwork.

4.4 SUBMITTALS

.1 Product Data:

.1 Provide manufacturers standard product information for each type of product to be installed.

.2 Provide product data sheets for equipment to be installed or connected by others.

.2 Shop Drawings:

.1 Indicate field and modular partition dimensions, general construction techniques, specific modifications, component connections, anchorage methods, hardware and installation procedures and similar requirements.

.2 Include plans, elevations, sections, component profiles, connection and attachment details, and finish schedule.

.3 Indicate locations and types of building services connections and supplementary or concealed supports.

.4 Where field measurements cannot be made without delaying the Work, establish dimensions on Shop Drawings for coordination by the General Contractor. Provide allowance for trimming at site, and coordinate construction to ensure that actual dimensions correspond to established dimensions.

.3 Samples: Provide samples for verification of support system and each type, color, and texture of exposed finish, full thickness and the following minimum sizes:

.1 Finishing Materials: Manufacturer's standard size, but not less than 50 x 50 mm (2 x 2 inches) by full thickness to be installed.

.2 Provide a sufficient number of samples to represent the full range, color, and grain to be expected.

.3 Hardware and Accessories:

.1 Standard: Manufacturer to provide one full sized unit including drilling patterns.

.4 Modular Millwork Schedule and Unit Prices:

.1 Provide a schedule with finishes organized by installation area, room, or project delivery package using designations on the Drawings.

.2 Final quantities, types and locations may be reviewed by others in addition to the Architect to confirm all necessary components and accessories are included, note special coordination or concerns on the schedule as required.

.3 Provide unit prices for each major component and accessories in the event items are added or removed, costs will be known and agreed ahead of time.

.5 Closeout Submittals:

.1 Maintenance data for incorporation into operation and maintenance manuals.

.2 Deliver 1% of each type of hardware actually installed, but not less than 2 sets.

.3 Warranties.

4.5 QUALITY ASSURANCE

.1 Single Source Responsibility: A single fabricator shall provide, oversee, coordinate and install the work described in this Section and shown on the Drawings.

.2 Manufacturer Qualifications:

.1 Specialist in designing and manufacturing Modular Architectural Woodwork of the quality and complexity required for this project with a minimum of 5 years documented successful experience, and with production facilities capable of meeting contract requirements for single‐ source responsibilities and warranty.

.3 Installer Qualifications:

.1 Minimum 2 years of documented experience of scope and complexity similar to work of this project.

.4 Pre‐Installation Conference:

.1 Meet at the project site minimum 1 week prior to beginning installation.

.2 Review methods of attaching each unique combination and condition.

4.6 DELIVERY, STORAGE AND HANDLING

.1 Do not deliver or install Modular Architectural Woodwork until spaces are enclosed and weather‐tight, wet work is complete and dry, work above ceilings is complete, and HVAC system is operational and able to maintain ambient temperature and humidity conditions at occupancy levels for the remainder of the construction period.

.2 Ship system components in manufacturers standard packaging. Maintain air circulation during shipment. Do not allow packaging to get wet or develop condensation.

.3 Deliver materials to project site in accordance with the manufacturers instructions in original unopened and undamaged packages. Packages shall be labeled with fabricators name, product identification and lot numbers, sizes, finishes, and placement locations.

.4 Store in a clean, dry, secure space to protect from damage during construction activities. Minimize or eliminate storage period by coordinating with construction schedule.

.5 Handle in accordance with the fabricators instructions.

4.7 PROJECT CONDITIONS

.1 Environmental Limitations: Do not deliver or install system and components until building is enclosed and finishing operations are complete, including adjacent ceiling and floor covering installation and painting.

.2 Temperature and humidity shall be maintained to final occupancy standards.

Installation areas shall be climate controlled between 60 and 90 degrees F (15.5 and 32.2 C) with Relative Humidity maintained between 25 and 55 percent.

4.8 WARRANTY

.1 Provide manufacturers standard, transferable warranty executed in the name of the Owner. Guarantee the site assembled modular structure, finishing materials and components are free from defects in material and workmanship.

.1 Warranty Period: 10 year limited warranty.

Part 5 Products

5.1 MANUFACTURERS

.1 DIRTT Environmental Solutions;

.1 Website: www.dirtt.net

.2 GSA Schedule:

.1 Contract: GS 07F 0005T.

.2 CCR#: 73193726.

.2 Substitutions: Not permitted without demonstrating compliance with aesthetic effects shown in the drawings, performance requirements and lead times specified above.

5.2 CORE MATERIALS

.1 Medium Density Fiberboard (MDF):

.1 Industrial grade to ANSI A208.2‐2002, MDF Classification MD, interior

MDF.

.2 Density: 48 pounds per cubic foot (769 kilograms per cubic meter).

.3 Minimum Thickness:

.1 Countertops: 1 inch (25 mm).

.2 Cabinet Sides, Door and Drawer Fronts: 3/4 inch (19 mm).

.3 Drawer Bodies: 5/8 inch (16 mm).

.6 Plywood: Provide for toe‐kick base support and where indicated on shop drawings.

.1 Either DOC PS 1 or DOC PS 2, unless otherwise indicated.

.2 Minimum thickness 3/4 inch (19 mm).

5.3 FINISHING MATERIALS

.1 Plastic Laminate: to NEMA LD 3:

.1 Typical: Thermofoil Finish (THRM):

.2 Paint: Chromacoat, UV cured water based, factory applied paint.

.3 Edge Banding:

.1 Countertops and as indicated: Self‐edge (thermofoil) to match horizontal surfaces with minimal visible seaming.

.2 Drawers and as indicated: PVC edge banding.

.7 Interior Finishes:

.1 Manufacturer’s standard melamine unless otherwise shown on Shop Drawings.

.2 Interior finish colors as shown on Shop Drawings.

.3 Melamine finish in concealed areas is only permitted when shown on Shop Drawings and as indicated in fabrication paragraphs below.

5.4 CABINET HARDWARE

.1 Frameless Concealed Hinges (European Type): BHMA A156.9, B01602.

.4 Typical Hinges: 107 degrees of opening, self‐closing, minimum two hinges per door, more where required by cabinet height and hinge manufacturer limitations.

.5 Custom Hinges: Require prior approval by manufacturer based on design and installation requirements.

.2 Drawer Slides: BHMA A156.9, B05111; Side‐mounted, full extension with integrated soft close sides.

.1 Typical: metal B, D, M or N premium series full extension drawer system with dynamic load capacity of minimum 34 kg (75 lbs).

.2 File Drawers: Plywood drawers equipped with aluminum file bars.

.3 Drawer and Door Pulls:

.1 Bow Pull: #117.31.632 from Hafele.

.2 Rod Pull: #305128195 from Richelieu.

.4 Internal Shelf Supports:

.1 Adjustable type, flattened self support pins of 5‐millimeter nickel.

.5 Counter Support Brackets: Unless otherwise shown on Shop Drawings, provide 6063 T6 "T" shaped extruded aluminum bracket with MIG welding across 45‐ degree miters and back.

.1 Load Capacity: 500 pounds (225 kg) per bracket minimum.

.2 Provide intermediate support brackets where counter span exceeds 1220 mm (48 inches). When multiple supports are required, space equally and coordinate locations with equipment and accessories.

.3 Basis of Design: Rakks Counter Support Bracket by the Rangine

Corporation or equivalent and approved.

.6 Grommets:

.1 Field determined

.2 ABC plastic grommets as manufactured by Doug Mocket & Company Inc., Richelieu, or equivalent and approved.

.3 Color and Material: [Black plastic]

.4 Diameter: 3 inch (76 mm).

.7 Metal Leg Levellers: Richelieu, type to suit cabinet weight and use.

5.5 FABRICATION

.1 Do not use materials with defects including but not limited to scratches, dents, irregular finishes or colors, materials which do not match accepted samples, or other variations in appearance or structural integrity.

.2 Prefinish all work at the fabrication shop unless specifically indicated on the Shop Drawings.

.3 Allow 0.078 inch (2 mm) clearance between door units, side panels, and drawers unless otherwise indicated.

.4 Base and Wall Cabinets: 19 mm (3/4 inch) MDF sides, tops, and bottoms assembled with metal bolt and brass inserts.

.5 Door and Drawer Cabinet Fronts: 19 mm (3/4 inch) MDF finished all sides.

.6 Cabinet Backs:

.1 Laminated or Painted Cabinets: 19 mm (3/4 inch) MDF with white or black thermally fused melamine on interior side.

.2 Wood Veneer Cabinets: 19 mm (3/4 inch) MDF with matching veneer.

.7 Drawer Boxes: 16 mm (5/8 inch) melamine bottom and back.

.8 Countertops: 25 mm (1 inch) MDF with finishes indicated.

.9 Shelves: Provide of the following material with concealed fasteners in locations and thickness shown on Shop Drawings.

.1 Solid Surfacing.

.2 MDF laminated on all exposed sides by finish indicated on the Drawings.

.3 As shown on Shop Drawings.

.10 Hanging Materials:

.1 Concealed unless specifically indicated on Shop Drawings.

.2 Cabinets on Base Building: French cleats pairs where lower cleat fastened to walls with internal blocking provided by others, and upper cleat fastened to Modular Architectural Woodwork in the factory or field as indicated on Shop Drawings.

.1 Manufacturers standard cleats of wood. Notify manufacturer if metal cleats are to be installed.

.2 Coordinate cleat location on casework with manufacturer through Shop Drawing process.

.3 Countertops: Support brackets as specified above, installed with screws, sealing all joints with continuous bead of silicone sealant prior to attachment.

5.6 FINISHES

.1 Provide the following as shown on the Drawings:

.1 Thermofoil Finish (THRM):

.1 Manufacturer: [SSI].

.2 Type: [TBD].

.3 Texture: [TBD].

.4 Color: [TBD].

.2 Paint Finish (PNT):

.1 Series: [Standard]

.2 Coating Type: Chromacoat or approved equivalent.

.3 Color: [TBD].

.6 Cabinet Hardware:

.1 Finish: [Brushed nickel] or [Black powder coat].

.2 Drawer Slides: Match drawer bodies.

Part 6 Execution

6.1 EXAMINATION

.1 Verify field or hold‐to control dimensions before fabrication of modular partitions. Coordinate fabrication schedule with construction schedule and progress to avoid delay in the work.

.2 Examine all adjoining work including work by others. Do not proceed with fabrication or installation until unsatisfactory conditions are corrected.

6.2 INSTALLATION

.1 Install materials and systems in accordance with Modular Partition manufactures written instructions or base building documents as applicable.

.3 Install system rigid, level, plumb, with uniform appearance and in proper relationship with adjacent construction maintaining alignments as indicated on the design documents and as directed by the Architect if not shown.

.4 Installation Tolerances:

.1 Plumb and Level: 3 mm (1/8 inch) or tighter in 2400 mm (96 inches).

.2 Install countertops, including L or other shaped counters, with no more than 3 mm (1/8 inch) sag, bow or other variation from a straight line over the entire length.

.3 Scribe Modular Architectural Woodwork and filler panels to ensure a tight fit, leaving no gaps larger than 3 mm (1/8 inch) in the final installation.

.5 Joint Sealing:

.1 Movable Installations: Ensure all currently exposed and future exposed finishes are not damaged, repair or replace as needed to the satisfaction of the Architect.

.2 Permanent installations: In addition to verifying finishes, fill all gaps including concealed gaps with silicone or other specified joint sealants.

.3 Responsibility for joint sealing is to be coordinated prior to installation or becomes the responsibility of the general contractor.

.6 Adjust doors, drawer fronts and cabinet hardware for proper operation.

6.3 CLEANING

.1 Upon completion of installation, components and finishes shall be cleaned in accordance with the finish manufacturers instructions. Alkaline or abrasive agents shall not be used. Avoid scratching or marring finishes.

6.4 PROTECTION

.1 Protect from damage through the duration of construction activities.

SECTION 3 ‐ ELECTRICAL SYSTEMS FOR MODULAR PARTITIONS

Part 1 General

1.1 SUMMARY

.1 Section includes:

.1 Electrical components for modular partition systems and components.

.2 Related Sections:

.1 064017 ‐ Modular Architectural Woodwork.

.2 102217 ‐ Modular Partitions.

.3 275317 ‐ Distributed Communications Systems for Modular Partitions.

.4 Base Building Documents:

.1 Division 06 Architectural Woodwork.

.2 Division 08 Doors and Door Hardware.

.3 Division 26 Electrical.

.4 Division 27 Communications.

.5 Division 28 Electronic Safety and Security

1.2 REFERENCES

.1 National Fire Protection Association (NFPA):

.1 NFPA 70 – National Electrical Code, 2008 Edition.

.2 Underwriters Laboratories (UL):

.1 UL 1286 – Office Furnishings.

.2 UL QQXX ‐ Sections and Units.

.3 UL 514A ‐ Standard for Safety for Metallic Outlet Boxes.

.4 UL 514C ‐ Standard for Safety for Non‐Metallic Outlet Boxes, Flush‐Device Boxes, and Covers.

.5 UL 514D ‐ Standard for Safety for Cover Plates for Flush‐Mounted Wiring Devices.

1.3 PERFORMANCE REQUIREMENTS

.1 Electrical work shall be inspected prior to installation of finishing panels.

.2 Coordination Requirements:

.1 Comply with Division 01 project management and procedures.

.2 Project Scheduling and Lead Times: Comply with Section 102217 ‐ Modular Partitions.

1.4 SUBMITTALS

.1 Product Data:

.1 Provide manufacturers standard product information for each type of product indicated.

.2 Shop Drawings:

.1 Indicate device type and location on Shop Drawing plans and elevations to confirm accurate scope of work has been captured from engineering plans or client. Coordinate as required until scope is confirmed by all affected parties.

.2 Adequate legends shall be provided to confirm electrical device specifications, amperage, trim ring and faceplate colors and styles, cable type, device type, and applicable level.

.3 Coordination Drawings:

.1 Provide shop drawings for coordination between trades upon request.

.2 Electrical: Coordinate electrical components specified herein with final circuited electrical engineering documents.

.4 Product Test Reports, Solid Partitions: Based on evaluation of comprehensive tests performed by a independent qualified testing agency:

.1 Evaluation/Certification Reports:

.1 ICC ESR (Evaluation Service Reports):

.1 [Site specific as required on fee basis].

.2 Intertek Listing Constructional Data Report demonstrating compliance with UL 1286 Office Furnishings.

.3 UL QQXX ‐ Sections and Units for electrical components.

.5 Maintenance Data: Provide maintenance data for incorporation into operation and maintenance manuals.

1.5 QUALITY ASSURANCE

.1 Factory Installed Electrical Components, Devices, and Accessories:

.1 Factory Inspections to support UL, Intertek (ETL), and other specified listings by independent accredited 3rd Party Agency.

.2 Field Installed Electrical Components, Devices, and Accessories:

.1 Connections to the base building electrical system and all field installed electrical components, devices, and accessories shall be performed by an electrical contractor licensed in the jurisdiction of the project in accordance with applicable building / electrical codes and standards.

.2 Such work shall be performed under permit, tested, and inspected to confirm adequacy of final installations and connections to the satisfaction of the Authority Having Jurisdiction.

1.6 DELIVERY, STORAGE AND HANDLING

.1 Ship system components in manufacturer’s standard packaging. Maintain air circulation during shipment. Do not allow packaging to get wet or develop condensation.

.2 Deliver materials to project site in accordance with the manufacturer’s instructions in original unopened and undamaged packages. Packages shall be labeled with manufacturers name, brand names, size, finishes, and placement locations.

.3 Store in a clean, dry, secure space to protect from damage during construction activities. Minimize or eliminate storage period by coordinating with construction schedule.

.4 Handle in accordance with the manufacturer’s instructions.

1.7 PROJECT CONDITIONS

.3 Environmental Limitations: Do not deliver or install system and components until building is enclosed and finishing operations are complete, including adjacent ceiling and floor covering installation and painting.

.4 Temperature and humidity shall be maintained to final occupancy standards.

Installation areas shall be climate controlled between 60 and 90 degrees F (15.5 and 32.2 C) with Relative Humidity maintained between 25 and 55 percent.

1.8 WARRANTY

.1 Provide manufacturers standard, limited, transferable warranty executed in the name of the Owner. Guarantee the site assembled electrical components are free from defects in material and workmanship.

.1 Warranty Period: 10 year limited warranty.

Part 2 Products

2.1 SYSTEM DESCRIPTION

.1 System can be provided with electrical and network components mounted at varying heights installed in accordance with Division 26 Electrical and 27 Communications and as indicated.

2.2 ELECTRICAL COMPONENTS ‐ GENERAL

.1 Electrical, Communications, and Security System Requirements: Provide for installation of electrical, communications, and security system items arranged so that wiring can be readily removed and replaced.

.1 Electrical Conduit: Typical, provide Electric Metal Tubing (EMT) conduit pathways [3/4 inch (21 mm)] in cavity of modular partitions, from outlet and device boxes to top or bottom of modular partitions to permit wiring installation and connections as specified in Divisions 26, 27, and 28.

.1 Typical EMT: [aluminum].

.2 Data / Communication Only: Option for 1 x 2 inch (25 x 50 mm) rectangular aluminum conduit. Show on Shop Drawings.

.2 Flex Conduit: Provide UL listed per ANSI/UL‐1, NEC Type FMC fabricated of lightweight, high‐strength aluminum alloy, only permitted in locations shown on Shop Drawings.

.3 Refer to Division 26, 27, and 28 Sections for conduit raceway and pull wire requirements.

.2 All electrical installations must be inspected as part of the electrical contractors scope prior to installation of face mounted finish tiles.

.1 Grounding paths must be verified in patient care areas.

2.3 ELECTRICAL COMPONENTS ‐ LEVEL 1

.1 Level 1 Conventional Electrical:

.1 Panel cut out and mounting brackets.

.2 Conventional back box (existing field installed).

.3 Frame vertical modification for horizontal frame to frame pass‐through.

Wall frame verticals on both sides of frame will be modified to provide 2 cutouts and a support bracket for frame to frame power/data pass‐ through.

.4 Does not include wiring/cabling, conduit, conduit connectors, devices or faceplates. These items are to be supplied and installed by electrical / data contractors and must be coordinated between trades accordingly.

.5 All home runs, connectors and connections are performed by electrical contractor.

Part 3 Execution

3.1 EXAMINATION

.1 Verify field or hold‐to control dimensions before fabrication of modular partitions. Coordinate fabrication schedule with construction schedule and progress to avoid delay in the work.

.2 Examine all adjoining work including work by others. Do not proceed with fabrication or installation until unsatisfactory…

This is the start of the file's text. The full file is on GovTribe.

File details come from the government source that posted it.