SERVICE - Sterile processing equipment maintenance Federal contract opportunity
Solicitation number
36C24818Q9832
Issued by
Department of Veterans Affairs Veterans Health Administration Veterans Integrated Service Network 8

About this file

36C24818Q9832 Steris SOW FY19.docx

View the file

Other files for this federal contract opportunity

Other files attached to SERVICE - Sterile processing equipment maintenance, newest first.
File Type Posted
36C24818Q9832-004.docx DOCX document
36C24818Q9832-003.docx DOCX document
36C24818Q9832-001.docx DOCX document
36C24818Q9832-000.docx DOCX document

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Statement of Work

Background:

The Malcom Randall VA medical Center, The Villages VA OPC, VA Tallahassee OPC, VA Jacksonville OPC, and Lake City VA Medical Center maintains an annual full-service contract on all SPS Steris equipment.

Objective:

This Service Contract is an annual full-service contract to keep all SPS Steris equipment in optimal operating condition.

Scope of Work:

Regularly scheduled visits to conduct preventive maintenance inspection at frequencies recommended by the original equipment manufacturer. Also, any corrective maintenance required to keep the units functioning at manufacturer specifications. Note- these units do not contain VA sensitive information. The contractor shall submit to the Biomedical Engineering Section, a service report indicating what repairs, service, calibration, etc., were performed. Each service ticket report must, at minimum, document the following data legibly and in complete detail:

A.Name of Contractor
B.Name of FSE who performed service
C.Contractor service ESR Number/Log number
D.Date and time (starting and ending) equipment downtime and hours on site for service call.
E.VA PO# covering the call, if outside normal working hours
F.Description of problems reported by user.
G.Identification of equipment to be serviced: INV, ID#, manufacturer's name, devises name, model#, Serial #, and any other manufacturer's identification#.
H.Itemized description of Service performed including labor and travel, parts (with part#) and materials and circuit location of problem/corrective actions.
I.Signatures:
J.FSE performing service described
K.VA Employee who witnessed the service described

This report shall be signed by the using designee attesting that the equipment is in satisfactory working order and is functioning at an acceptable level of performance.

The following equipment shall be covered under the service contract:

Equipment DescriptionSerial #
20 IN. CENT VAC SD 480V CAB STERILIZER
033141225
20 IN. CENT VAC SD 480V CAB STERILIZER
032791221
SYN W/DISINF 480V,3PH,60HZ,ELE(SFDA 20081573688)
3632412007
SYN W/DISINF 480V,3PH,60HZ,ELE(SFDA 20081573688)
3633211015
CAVIWAVE ULTRSNC CONSOL L2R 208V/3PH
0211C1216
AMSCO 400 20X20X38 PVAC SD SLIDE REC ELEC 480V
032711710
48 IN. PLATFORM PREVAC STERILIZER DBL HINGE L-L REC 1 WALL 208/240 V 3 PH
032010708
48 IN. PLATFORM PREVAC STERILIZER DBL HINGE L-L REC 1 WALL 208/240 V 3 PH
031480702
RELIANCE SYNERGY WASHER/DISINFECTOR 208V,3PH,4 WIRE,60HZ- (R5)
3616607005
REL 444 WSHR SGL P DR 208 (BEFORE SN)
3614897002
20X20X38 CENTURY GRAVITY STERILIZER SD LIQ CYC
012110206
16 IN. CENT VAC SD STM REC
031141205
1227 C & UTENSIL W/DISINF 200-208V,60HZ,STEAM,DMD
3633112020
MEDISAFE SONIC IRRIGATOR PCF W DISINFECT
2163208402
48 IN.PLATFORM PREVAC STERILIZER,DBL HINGE,L-R,REC 2-WALL,480V
012400402
48 IN.PLATFORM PREVAC STERILIZER,DBL HINGE,L-R,REC 2-WALL,480V
012720504
48 IN.PLATFORM PREVAC STERILIZER,DBL HINGE,L-R,REC 2-WALL,480V
012850505
16 IN. CENT VAC SD STM CAB
032350722
16 IN. CENT VAC SD STM CAB
032490707
16 IN. CENT VAC SD STM CAB
032390703
VISION (SC) 460-480V, 3PH, 60HZ, STEAM
3629909001
VISION (SC) 460-480V, 3PH, 60HZ, STEAM
3630209010
VISION (SC) 460-480V, 3PH, 60HZ, STEAM
3630809010
REL 444 WSHR SGL P DR 460
3623207005
BASIC MOTORIZED
3635109002
MOTORIZED WITH FEED IN
3600410007
MOTORIZED WITH FEED IN
3600510001
MOTORIZED WITH FEED IN
3635209001
1227 C & UTENSIL W/DISINF 200-208V,60HZ,STEAM,DMD
3632612001
MEDISAFE SONIC IRRIGATOR PCF W DISINFECT
1163208308
MEDISAFE SONIC IRRIGATOR PCF W DISINFECT
1163208401
MEDISAFE SONIC IRRIGATOR PCF W DISINFECT
2163208404
EVOLUTION VAC 54 IN ELEC DD HNG RL R2W 480V
033191620
V-PRO MAX, SD, CAB, 208/230V, 60HZ ENGLISH (OOME)
033071608
EVOLUTION VAC 54 IN ELEC DD HNG LR R2W 480V
033301613
EVOLUTION VAC 54 IN ELEC DD HNG LR R2W 480V
033401607
EVOLUTION VAC 54 IN ELEC DD HNG RL R2W 480V
033301615
CAVIWAVE ULTRSNC CONSOL L2R 208V/3PH
0310C0759
SYN W/DISINF 480V,3PH,60HZ,ELE(SFDA 20081573688)
3623110006
20 IN. CENT VAC SD 480V CAB STERILIZER
032071003
20 IN. CENT VAC SD 480V CAB STERILIZER
032381002
CAVIWAVE ULTRASONIC CLEANER 20 GAL 208V/3PH/132KHZ
0816TC0015
AMSCO 400 20X20X38 PVAC SD SLIDE REC ELEC 480V
031611665
VISION (SC) 460-480V, 3PH, 60HZ, ELECTRIC
3616516003
VISION (SC) 460-480V, 3PH, 60HZ, ELECTRIC
3616516002

Qualification / Certifications / Safety The contractor shall obtain all necessary licenses and or permits required to perform this work. He or she must be fully qualified/certified to service the equipment indicated in the scope of work and must present qualifications to Biomedical Engineering to keep in the service contract file.

The VA Safety Officer shall have full authority to see that the contractor obeys all safety rules and regulations to the fulfillment of this contract.

Scheduling Hours of Work:

All work involved shall be scheduled with the Sterile Process Service and/or Biomedical Engineering section at 352-548-6000x2433.