36C24818Q9789 Attachment B Salient Characteristics Urology.docx
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| -15114.docx | DOCX document | |
| 36C24818Q9789-000.docx | DOCX document | |
| 36C24818Q9789-003.docx | DOCX document | |
| 36C24818Q9789-001.docx | DOCX document |
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Attachment B 36C24818Q9789 Salient Characteristics
· Compatible with the existing Karl Storz endoscopic system currently in-use at the Miami VAMC Operating Room.
· Current compliance with the standardization of the Sterile Processing Services with the current endoscopic equipment in our facility.
· Office Cart with IV Pole
· T-Post/Stand
· Transformer
· 1 Shelf
· 26” LED Monitor
· 1920x1080 resolution
· 16:0 Aspect Ratio
· Full HD Camera (equivalent to -IMAGE1S-H3XKT-UG)
· H3-Link and X-Link with keyboard and USB to ACC Adapter
· Dashboard- overview with user guidance
· Live menu (able to customize)
· Automatic light source control
· Side-by-side view: parallel display of standard image and visualization mode possible
· Provides true-to-life color reproduction and impresses with a natural color rendition
· Possibility of combining both the CLARA and CHROMA technologies
· Advanced Image and Data acquisition- Hd Connect W/SmartScreen with DVD
· Enables optimal documentation- still images and videos being recorded in Full HD and 3D
· Image Resolution: Up to 1920 x 1080, 16:9
· Video resolution: Up to 1920 x 1080, progressive scan at 25/30 frames per second
· Completed procedures, still images, videos, and checklist report can be retrieved
· Edit module where simple adjustments to recorded still images and videos can be rapidly completed
· Recordings can directly be placed in the report
· Freeze frames can be cut out of videos, and markings can be used
· Video Endoscope Adaptor
· Flexible Video Cystoscope
· LED illumination
· Digital-all-in-one system
· CMOS Chip technology
· Potable monitor with USB and HDMI port, SD memory card and rechargeable Li-ion batteries
· Able to document images and videos
· Option to connect to an external monitor
· Plastic Container for Sterilization—Sterrad Compatible Videoendoscope Tray
· Suited for gas and hydrogen peroxide sterilization and storage, perforated, with lid, for use with flexible video cystoscopes
· Medical grade Printer
· For use with USB/wireless option
· Xenon Light Source Kit
· With turret adaptor
· Double Stopcock Adapter, Luer-Lock with O2-Hose Connection
· Flexible Cystoscope
· Equal to CHNL:7FR, 15FRX36CM US Deflection:140˚D/210˚
· Image1 Camera Head
· 1080 HD for Image1 S X-Link Module, UG
· Light Cable,