Attachment B 36C24818Q0698
STATEMENT OF WORK & SALIENT CHARATERISTICS
NF/SG VA Medical Centers InnoWave PCF Sonic Irrigator Thermal Disinfection Installation
1. Basic Information: The Malcom Randall VA Medical Center, Lake City VA Medical Center, The Villages OPC and Jacksonville OPC. has the need for five (5) InnoWave PCF Sonic Irrigator Thermal Disinfection systems with Installation and training packages.
2. Scope of Work: The offeror shall provide all resources necessary to accomplish the deliverables for installation of five (5) InnoWave PCF Sonic Irrigator Thermal Disinfection systems for the ultrasonic washing of instrumentation. Installation of each InnoWave PCF Sonic Irrigator Thermal Disinfection will be coordinated between the SPS Assistant Service Chief and offeror after award. All ultrasonic disinfection cycles will be agreed upon before installation. Training and Education shall be provided to varies shifts of SPS Department Employees on how to operate and troubleshoot the system. During installation the offeror shall adhere to all PPE and Safety polices of SPS, VA, and Federal Regulations and policies. A copy of these policies will be given at time of award or soon thereafter.
3. Place of Performance: Designated SPS Decontamination Areas inside the Malcolm Randall VA Medical Center, located at 1601 S.W. Archer Road Gainesville, FL 32608 during the hours of 8:00 PM – 8:00 AM Monday-Friday or Saturday-Sunday at the coordinated and scheduled time.
4. Storage: The equipment shall be securely stored at the Gainesville, FL Logistics Warehouse upon delivery until an installation date and times has been coordinated.
InnoWave PCF Sonic Irrigator Thermal Disinfection Salient Characteristics High Pressure Ultrasonic Flushing Washer Disinfector
· Up to 10 Robotic Instruments
· Sonic Irrigation
· Easy control : touch screen interface
· Thermal disinfection (A0 3000)*
· Instrument manufacturer approved
· 20+ cannulated instruments
· Water utilization program
· Traceability system compatibility
· CFPP 0101/EN ISO 15883 compliant (US)
· AAMI TIR 30 & 12 compliant
· High volume throughput
· Automatic locking lid
· WRAS Compliant
· Must be compatiable with NF/SG current ultrasonic systems and consumable The InnoWave PCF Sonic Irrigator Thermal Disinfection must clean and disinfect 20-40 lumened instruments in a single uninterrupted cycle. The instrument reprocessing workstation must be able to be used as a standalone unit, twin or multiple wash station. The InnoWave PCF Sonic Irrigator Thermal Disinfection ~ Parametrically Controls the Flow through the lumened devices optimizing both mechanical and chemical cleaning action inside the cannula while simultaneously controlling the propagation of unwanted wash foam build up. The inline Thermal Disinfection System is used to raise the temperature of the water in the rinse phase following both internationally recognized time temperature relationships and the A0 calculation.
InnoWave PCF Sonic Irrigator Thermal Disinfection ensures all surfaces internal and external are exposed and are disinfected almost regardless of their length or bore. Unlike conventional washers, the InnoWave PCF Sonic Irrigator Thermal Disinfection delivers an exceptionally high pressure of wash fluid to the lumened instrument or device. Both the CPE™ (Cannulated Pulse Enhancement) and “Power Flush” systems have been scientifically tested to remove 92% of soluble residues in the first 20 seconds of the pre-wash phase, and the remainder of insoluble residues in the main wash phase.