36C24818Q0538-004.docx
DOCX document 15 KB Posted
- Attached to
- EQUIPMENT: ICU BED SYSTEMS Federal contract opportunity
- Solicitation number
- 36C24818Q0538
About this file
36C24818Q0538 36C24818Q0538_2.docx
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| -13622.docx | DOCX document | |
| 36C24818Q0538-005.docx | DOCX document | |
| 36C24818Q0538-006.docx | DOCX document | |
| 36C24818Q0538-007.docx | DOCX document | |
| 36C24818Q0538-003.docx | DOCX document | |
| 36C24818Q0538-002.docx | DOCX document | |
| 36C24818Q0538-001.docx | DOCX document | |
| 36C24818Q0538-000.docx | DOCX document |
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
FedBizOpps Amendment to a Previous Combined Solicitation
CLASSIFICATION CODE
SUBJECT
CONTRACTING OFFICE'S
ZIP-CODE
SOLICITATION NUMBER
BASE NOTICE TYPE
RESPONSE DATE (MM-DD-YYYY)
ARCHIVE
DAYS AFTER THE RESPONSE DATE
RECOVERY ACT FUNDS
SET-ASIDE
NAICS CODE
CONTRACTING OFFICE
ADDRESS
POINT OF CONTACT
(POC Information Automatically Filled from User Profile Unless Entered)
DESCRIPTION
See Attachment
AGENCY'S URL
URL DESCRIPTION
AGENCY CONTACT'S EMAIL
ADDRESS
EMAIL DESCRIPTION
ADDRESS
POSTAL CODE
COUNTRY
ADDITIONAL INFORMATION
GENERAL INFORMATION
PLACE OF PERFORMANCE
* = Required Field FedBizOpps Amendment to a Previous Combined Solicitation Rev. March 2010
EQUIPMENT: ICU BED SYSTEMS
33744 36C24818Q0538 04-04-2018 N 339113 Department of Veterans Affairs Network Contracting Office 8 (248) Room 327, Bldg. 2 10,000 Bay Pines Blvd Bay Pines FL 33744 Mark L. Cline mark.cline@va.gov 727-399-3342 C.W. Bill Young VAMC 10,000 Bay Pines Blvd.
Bay Pines, FL.
33744
USA
www.va.gov Department of Veterans Affairs mark.cline@va.gov Contract Specialist VA Bay Pines EQUIPMENT: ICU BED SYSTEMS Questions FBO Solicitation Number: 36C24818Q0538
1. Which is the correct RFQ number VA24818Q0523 or VA24818Q0538?
Answer: VA24818Q0538
2. What model number of the Progressa bed is the reference referring to?
Answer: Model 885
3. An intended use of the bed system is to treat or prevent pulmonary or other complications associated with immobility. Please clarify: Is Continual Lateral Rotation Therapy (CLRT) required? Is Percussion and Vibration (P&V) required?
Answer: Yes, both are required.
4. Must have Supine to Sit to stand functionality. Please clarify if full chair foot egress is required?
Answer: Yes
5. Is a motorized drive system required?
Answer: Yes
6. Is an integrated O2 tank holder required?
Answer: Yes
7. Is a caregiver pendant required?
Answer: Yes
8. Is a permanent IV pole required?
Answer: Yes
9. Is it required to have powered length adjustment with the push of a button?
Answer: Yes
10. Is an accessory outlet required?
Answer: Yes
11. Is the bed required to connect to nurse call, universal TV, and lighting?
Answer: Yes
12. Is advanced articulation technology required that extends the head section of the frame and surface in unison to accommodate the natural elongation of the body which greatly reduces shear and friction on the patient’s skin as the head of bed is raised and lowered numerous times a day?
Answer: Yes
13. Is BioMed Certification Training required versus the standard user training that is included at delivery?
Answer: Standard training only.