36C24725Q0837.docx
DOCX document 46 KB Posted
- Attached to
- LECIA VT1200S VIBRATOME Federal contract opportunity
- Solicitation number
- 36C24725Q0837
About this file
This document is a Combined Synopsis/Solicitation Notice for a Leica VT1200S Vibratome issued by the Department of Veterans Affairs (VA) VISN 7 Network Contracting Activity. The solicitation, numbered 36C24725Q0837, seeks to procure one fully automated vibrating blade microtome for the Dorn VA Medical Center in Columbia, SC, with a response deadline of July 22, 2025 at 07:00 AM Eastern Time. The procurement is unrestricted and full and open competition, with a firm fixed price contract type and NAICS code 334516. The solicitation is specifically for a brand name or equal Leica VT1200S Vibratome, which includes detailed technical specifications such as vertical specimen feed up to 20mm, horizontal stroke of 45mm, operating temperature range of 10-35°C, and integrated features like LED illumination, cryo-manipulator, and multiple operational modes.
The solicitation is structured as a Request for Quote (RFQ) with evaluation based on technical and price factors. Interested service-disabled veteran-owned small business (SDVOSB) offerors must be registered in SAM.gov and listed in SBA's VetCert. The procurement includes multiple line items: the primary Leica VT1200S Vibratome, a power cord, and a Vibrocheck measurement device. Quotes must be submitted via email to joseph.locke@va.gov with the solicitation number in the subject line, and the contracting specialist is Rudy A. Cortinez from the Augusta, GA office. The equipment will be used at the Dorn VA Medical Center located at 6439 Garners Ferry Rd in Columbia, SC.
View the file
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Combined Synopsis/Solicitation Notice Combined Synopsis/Solicitation Notice
| SUBJECT* |
| LECIA VT1200S VIBRATOME |
GENERAL INFORMATION
| CONTRACTING OFFICE’S ZIP CODE* |
| 30901 |
| SOLICITATION NUMBER* |
| 36C24725Q0837 |
| RESPONSE DATE/TIME/ZONE |
| 07-22-2025 07:00 EASTERN TIME, NEW YORK, USA |
| ARCHIVE |
| 15 DAYS AFTER THE RESPONSE DATE |
| RECOVERY ACT FUNDS |
| N |
SET-ASIDE
| PRODUCT SERVICE CODE* |
| 6640 |
| NAICS CODE* |
| 334516 |
| CONTRACTING OFFICE ADDRESS |
| Department of Veterans Affairs |
VISN 7 Network Contracting Activity 501 Greene Street Hatcher Building - Suite 2 Augusta GA 30901
POINT OF CONTACT*
Contracting Specialist Rudy A. Cortinez rudy.cortinez@va.gov
PLACE OF PERFORMANCE
| ADDRESS |
| Department of Veterans Affairs |
Dorn VA Medical Center
6439 Garners Ferry Rd, Columbia SC
| POSTAL CODE |
| 29209 |
| COUNTRY |
| USA |
ADDITIONAL INFORMATION
| AGENCY’S URL |
| https://www.va.gov/columbia-south-carolina-health-care/ |
| URL DESCRIPTION |
| Columbia SC Healthcare System |
| AGENCY CONTACT’S EMAIL ADDRESS |
| rudy.cortinez@va.gov |
| EMAIL DESCRIPTION |
| Contracting Specialist e-mail address. |
DESCRIPTION
This is a combined synopsis/solicitation for commercial items prepared in accordance with the format in Federal Acquisition Regulation (FAR) subpart 12.6, “Streamlined Procedures for Evaluation and Solicitation for Commercial Items,” as supplemented with additional information included in this notice. This announcement constitutes the only solicitation; quotes are being requested.
· Agency: The Department of Veterans Affairs,
· Facility: Dorn VA Medical Center Columbia SC
· Location: 6439 Garners Ferry Rd Columbia SC 29209
· Brand Name or Equal requirement
· The Brand Name is Leica
· The Brand Name Description is LECIA VT1200S VIBRATOME
· The solicitation is issued on an Unrestricted basis, Full and Open Competition.
· Rationale: Market research documented no competitive grouping exists to support a set-aside.
· Requirement: New; no existing contract.
· Contract Type: Firm Fixed Price request
This solicitation is issued as an RFQ. The solicitation document and incorporated provisions and clauses are those in effect through Federal Acquisition Circular 2025-01 effective 11/12/2024.
The combined synopsis solicitation is UNRESTRICTED Note: Interested SDVOSB offerors must be registered in SAM.gov and be listed in SBA’s VetCert to be considered for Award.
The associated North American Industrial Classification System (NAICS) code for this procurement is 339113, with a small business size standard of 750 employees. The FSC/PSC is 6640.
LINE ITEM DESCRIPTION
| ITEM NO. |
| DESCRIPTION |
| QTY |
| Discounted Price |
| Actual Price/Cost |
| 1491200S001 |
| FULLY AUTOMATED LEICA VT1200 S |
| 1 EA |
| 14041157009 |
| POWER CORD NEMA5 15 |
| 1 EA |
| 14048142075 |
| VIBROCHECK |
| 1 EA |
The following Commercial Items clauses apply to this acquisition:
52.252-2 CLAUSES INCORPORATED BY REFERENCE (FEB 1998)
This contract incorporates one or more clauses by reference, with the same force and effect as if they were given in full text. Upon request, the Contracting Officer will make their full text available. Also, the full text of a clause may be accessed electronically at this/these address(es):
http://www.acquisition.gov/far/index.html http://www.va.gov/oal/library/vaar/
| FAR |
| Title |
| Date |
| 52.204-13 |
| SYSTEM FOR AWARD MANAGEMENT MAINTENANCE |
| Oct 2018 |
| 52.204-18 |
| COMMERCIAL AND GOVERNMENT ENTITY CODE MAINTENANCE |
| Aug 2020 |
| 52.209-6 |
| PROTECTING THE GOVERNMENT'S INTEREST WHEN SUBCONTRACTING WITH CONTRACTORS DEBARRED, SUSPENDED, OR PROPOSED FOR |
DEBARMENT
Nov 2021
| 52.211-6 |
| BRAND NAME OR EQUAL |
| AUG 1999 |
| 52.212-4 |
| CONTRACT TERMS AND CONDITIONS-COMMERCIAL ITEMS |
| Dec 2022 |
| 52.212-5 |
| CONTRACT TERMS AND CONDITIONS REQUIRED TO IMPLEMENT STATUES OR EXECUTIVE ORDERS |
| Mar 2023 |
| 52.222-3 |
| CONVICT LABOR |
| Jun 2003 |
| 52.222-19 |
| CHILD LABOR – COOPERATION WITH AUTHORITIES AND REMIDIES |
| Dec 2022 |
| 52.222-36 |
| EQUAL OPPORTUNITY FOR WORKERS WITH DISABILITIES |
| Jun 2020 |
| 52.222-50 |
| COMBATING TRAFFICKING IN PERSONS |
| Nov 2021 |
| 52.222-54 |
| EMPLOYMENT ELIGIBILITY VERIFICATION |
| May 2022 |
| 52.223-18 |
| ENCOURAGING CONTRACTOR POLICIES TO BAN TEXT MESSAGING WHILE |
DRIVING
Jun 2020
| 52.225-1 |
| BUY AMERICAN-SUPPLIES |
| Oct 2022 |
| 52.225-13 |
| RESTRICTIONS ON CERTAIN FOREIGN PURCHASES |
| Feb 2021 |
| 52.232-33 |
| PAYMENT BY ELECTRONIC FUNDS TRANSFER-SYSTEM FOR AWARD |
MANAGEMENT
Oct 2018
| 52.232-40 |
| PROVIDING ACCELERATED PAYMENTS TO SMALL BUSINESS |
SUBCONTRACTORS
Mar 2023
| 852.212-71 |
| GRAY MARKET AND COUNTERFEIT ITEMS |
| Feb 2023 |
| 852.212-72 |
| GRAY MARKET AND COUNTERFEIT ITEMS (DEVIATION) |
| Feb 2023 |
Page 1 of
VAAR 852.203-70 COMMERCIAL ADVERTISING (MAY 2018)
The bidder or offeror agrees that if a contract is awarded to him/her, as a result of this solicitation, he/she will not advertise the award of the contract in his/her commercial advertising in such a manner as to state or imply that the Department of Veterans Affairs endorses a product, project or commercial line of endeavor.
(End of Clause)
VAAR 852.211-70 EQUIPMENT OPERATION AND MAINTENANCE MANUALS (NOV 2018)
The Contractor shall follow standard commercial practices to furnish manual(s), handbook(s) or brochure(s) containing operation, installation, and maintenance instructions, including pictures or illustrations, schematics, and complete repair/test guides, as necessary, for technical medical equipment and devices, and/or other technical and mechanical equipment provided per all CLIN’s. The manuals, handbooks or brochures shall be provided in hard copy, soft copy or with electronic access instructions, consistent with standard industry practices for the equipment or device. Where applicable, the manuals, handbooks or brochures will include electrical data and connection diagrams for all utilities. The documentation shall also contain a complete list of all replaceable parts showing part number, name, and quantity required.
(End of Clause)
VAAR 852.219-76 VA NOTICE OF LIMITATIONS ON SUBCONTRACTING—CERTIFICATE OF COMPLIANCE FOR SUPPLIES AND PRODUCTS (JAN 2023) (DEVIATION)
(a) This solicitation includes VAAR 852.219-10 VA Notice of Total Service-Disabled Veteran- Owned Small Business Set-Aside (NOV 2020);
(b) Accordingly, any contract resulting from this solicitation is subject to the limitation on subcontracting requirements in 13 CFR 125.6. The Contractor is advised that in performing contract administration functions, the Contracting Officer may use the services of a support contractor(s) retained by VA to assist in assessing the Contractor's compliance with the limitations on subcontracting or percentage of work performance requirements specified in the clause. To that end, the support contractor(s) may require access to Contractor's offices where the Contractor's business records or other proprietary data are retained and to review such business records regarding the Contractor's compliance with this requirement.
(c) All support contractors conducting this review on behalf of VA will be required to sign an “Information Protection and Non-Disclosure and Disclosure of Conflicts of Interest Agreement” to ensure the Contractor's business records or other proprietary data reviewed or obtained in the course of assisting the Contracting Officer in assessing the Contractor for compliance are protected to ensure information or data is not improperly disclosed or other impropriety occurs.
(d) Furthermore, if VA determines any services the support contractor(s) will perform in assessing compliance are advisory and assistance services as defined in FAR 2.101, Definitions, the support contractor(s) must also enter into an agreement with the Contractor to protect proprietary information as required by FAR 9.505-4, Obtaining access to proprietary information, paragraph (b). The Contractor is required to cooperate fully and make available any records as may be required to enable the Contracting Officer to assess the Contractor's compliance with the limitations on subcontracting or percentage of work performance requirement.
(End of clause)
Page 1 of
VAAR 852.232-72 ELECTRONIC SUBMISSION OF PAYMENT REQUESTS (NOV 2018)
(a) Definitions. As used in this clause—
(1) Contract financing payment has the meaning given in FAR 32.001.
(2) Designated agency office has the meaning given in 5 CFR 1315.2(m).
(3) Electronic form means an automated system transmitting information electronically according to the Accepted electronic data transmission methods and formats identified in paragraph (c) of this clause. Facsimile, email, and scanned documents are not acceptable electronic forms for submission of payment requests.
(4) Invoice payment has the meaning given in FAR 32.001.
(5) Payment request means any request for contract financing payment or invoice payment submitted by the contractor under this contract.
(b) Electronic payment requests. Except as provided in paragraph (e) of this clause, the contractor shall submit payment requests in electronic form. Purchases paid with a Government-wide commercial purchase card are considered to be an electronic transaction for purposes of this rule, and therefore no additional electronic invoice submission is required.
(c) Data transmission. A contractor must ensure that the data transmission method and format are through one of the following:
(1) VA’s Electronic Invoice Presentment and Payment System. (See Web site at http://www.fsc.va.gov/einvoice.asp.)
(2) Any system that conforms to the X12 electronic data interchange (EDI) formats established by the Accredited Standards Center (ASC) and chartered by the American National Standards Institute (ANSI). The X12 EDI Web site (http://www.x12.org) includes additional information on EDI 810 and 811 formats.
(d) Invoice requirements. Invoices shall comply with FAR 32.905.
(e) Exceptions. If, based on one of the circumstances below, the contracting officer directs that payment requests be made by mail, the contractor shall submit payment requests by mail through the United States Postal Service to the designated agency office. Submission of payment requests by mail may be required for:
(1) Awards made to foreign vendors for work performed outside the United States;
(2) Classified contracts or purchases when electronic submission and processing of payment requests could compromise the safeguarding of classified or privacy information;
(3) Contracts awarded by contracting officers in the conduct of emergency operations, such as responses to national emergencies;
(4) Solicitations or contracts in which the designated agency office is a VA entity other than the VA Financial Services Center in Austin, Texas; or
(5) Solicitations or contracts in which the VA designated agency office does not have electronic invoicing capability as described above.
(End of Clause)
VAAR 852.246-71 REJECTED GOODS (OCT 2018)
(a) Supplies and equipment. Rejected goods will be held subject to Contractor’s order for not more than 15 days, after which the rejected merchandise will be returned to the Contractor's address at the Contractor’s risk and expense. Expenses incident to the examination and testing of materials or supplies that have been rejected will be charged to the Contractor.
(b) Perishable supplies. The Contractor shall remove rejected perishable supplies within 48 hours after notice of rejection. Supplies determined to be unfit for human consumption will not be removed without permission of the local health authorities. Supplies not removed within the allowed time may be destroyed. The Department of Veterans Affairs will not be responsible for, nor pay for, products rejected. The Contractor will be liable for costs incident to examination of rejected products. (End of Clause) (c) Page 1 of Instruction to Offerors
All quoters shall submit your Quotes no later than JULY 22, 2025, at 07:00AM (EST), via email to joseph.locke@va.gov. Please place in “ATTENTION: 36C24725Q0837 Leica VT1200 VIBRATOME” in the subject line of your email. All offers must include the solicitation number. Late submissions shall be treated in accordance with the solicitation provision at FAR 52.212-1(f).
Award will be based upon a comparative evaluation of quotes in accordance with the Simplified Acquisition Procedures of FAR 13. Comparative evaluation is the side by side pairwise comparison of quotes based on factors resulting in a Contracting Officer decision for the quote most favorable to the Government.
The following are the decision factors:
Technical Price
Any questions or concerns regarding this solicitation should be forwarded in writing via e-mail to the Point of Contact listed below.
Point of Contact Rudy A. Cortinez Contracting specialist Network Contracting Office 7 rudy.cortinez@va.gov
Salient Characteristics Fully Automated Vibrating Blade Microtome Blade Holder Removable ice tray (drawer principle) allows preparation of the tissue under the microscope with integrated palm rests with magnets to hold buffer tray in place Buffer tray (metal) Adjustment screw to minimize the vertical deflection of blade below 1um Separate control panel for optional semiautomatic cutting mode Vibrocheck measurement device for vertical deflection of blade Vertical Specimen feed: max 20mm Horizontal stroke: 45 mm – blade holder turnable by 90° Single or continuous mode-Specimen retraction during blade holder return stroke adjustable between 0 and 100 µm in 10 µm steps Operating temperature range: min. 10 °C - max. 35 °C Buffer tray (plastics) with lid to cover up buffer tray while filling ice tray Magnet to hold specimen disc in place Frequency: 85 Hz +/- 5 Hz-Selection between semi-motorized or fully automatic cutting mode Selection between vibration on or off during manual blade forward or return movement to approach specimen ‘Up' button for fast approach of the specimen to the blade Down' button for fast approach of the home position for safe and fast specimen change Integrated LED illumination, individually programmable in 5 steps Adapter for magnifier or microscope carrier Tool set Allen Key with handle Cryo-manipulator Fuses Dust cover Power cord
Dimensions:
L x W x H: ............................................................................600 mm x 250 mm x 230 mm Height with magnifier: ..........................................................600 mm x 250 mm x 320 mm Height with microscope: ......................................................600 mm x 250 mm x 469 mm Control unit (when the bases are folded in): .........................190 mm x 150 mm x 72 mm Weight:
Without magnifier support and control unit: ..............................................................56 kg VT1200 S control unit: ................................................................................................1 kg Magnifier support: ...................................................................................................... 2 kg Microscope support with stereomicroscope: ............................................................4.3 kg