VAMC Augusta, Georgia
DATE:
PROJECT NO.
DRAWING NO.
DWG. of
PROJECT TITLE:
DRAWING TITLE:
VIRGO GAMBILL
2 5 3 1 C E N T E R W E S T P A R K W A Y, A R C H I T E C T S
S U I T E 200 A U G U S T A , G E O R G I A 30909
( 7 0 6 ) 7 3 6 - 3 6 6 1
509-09-119
JUNE 13, 2013
STERILE PROCESSING SERVICE (SPS)
RENOVATE
100% SUBMITTAL
M E M B E R S O F T H E A M E R I C A N I N S T I T U T E
REPRODUCTION, COPYING, OR OTHERWISE
GAMBILL ARCHITECTS. THE UNAUTHORIZED
THIS DOCUMENT IS PROPERTY OF VIRGO
O F A R C H I T E C T S
2007 C
THEREUPON IS SUBJECT TO LEGAL ACTION.
PROHIBITED AND ANY INFRINGEMENT
VIRGO GAMBILL ARCHITECTS
USE OF THIS DOCUMENT IS STRICTLY
JMF
REVISIONS: DATE:
CHECKED BY:
DRAWN BY:
AREA OF WORK
KEY PLAN
801- M3.1
XX XX
HVAC NEW WORK PIPING PLAN
WDP
1B-190A
CONFERENCE
1B-107B
STERILE
SUPPLY
STORAGE
BREAK
ROOM
EQUIPMENT
ROOM
ANTE-ROOM
RECEIVING
SCOPE
ANTE
ROOMCLEAN
ROOM
MEDIVATOR
ROOM
CLEAN
SCOPE
ANTE-ROOM
ANTE
ROOM
ANTE
ROOM
MANUAL
WASH
ROOM
MEN'S
LOCKER/
BATH
WOMEN'S
LOCKER/
BATH
CLEAN
DISPATCH
CORRIDOR
CORRIDOR
STERADS AERATOR
ROOM
ETO
STERILIZER
MEN'S
LOCKER
ANTE
ROOM
WOMEN'S
BATH
DECONTAMINATION
AREA
ELEC.
ROOM
SOILED
ANTE
RECEIVING
SOILED
RECEIVING
DOUBLE
OFFICE
OFFICE
DETERGENT
CHIEF
SPS
ASSIST.
CHIEF
SPS
PREP/
STERILIZATION
AND
ASSEMBLY
AREA
NEW
CORRIDOR
TRIPLE
OFFICE
CLERK
WOMEN'S
LOCKER
MEN'S
BATH
1B-210 D
HACHAC
STORAGE
WOMEN'S
TLT.
MEN'S
TLT.
CRU-1 CORRIDOR
CORRIDOR
1B-210B
1B-210C
1B-210E
1B-110
1B-210F
1B-210G
1B-210H
1B-210
1B-210A
1B-137A
1B-137B 1B-139
1B-192
C1-22
1A-107
1A-106
C1-109
1A-107B
1B-207
1B-192A 1B-129B
1B-1941B-137F
1B-195
1B-193
1B-136
1B-136C
1B-109A
1B-136A
1B-109
1B-136B
1B-191A
1B-191
1B-193A
1B-190
C1-20
C1-109
1B-137
1B-204
1B-137E
1B-137C
C1-36A
1B-1071B-107A
1B-109B
1B-111
NONSTERILE STORAGE AREA
EXIST. STERILE /
T3
I N S U L A T E D
G R O U N D E D
C O N D U C T I V E L I V E
36" INSULATED
42" GROUNDED
48" CONDUCTIVE/LIVE
I N S U L A T E D
G R O U N D E D
C O N D U C T I V E L I V E
36" INSULATED
42" GROUNDED
48" CONDUCTIVE/LIVE
I N S U L A T E D
G R O U N D E D
C O N D U C T I V E L I V E
36" INSULATED
42" GROUNDED
48" CONDUCTIVE/LIVE
EXISTING FIRE WALL.
CONTRACTOR TO MAINTAIN
INTEGRITY OF WALL
DURING CONSTRUCTION
EXISTING FIRE WALL.
CONTRACTOR TO MAINTAIN
INTEGRITY OF WALL
DURING CONSTRUCTION
EXISTING FIRE WALL.
CONTRACTOR TO MAINTAIN
INTEGRITY OF WALL
DURING CONSTRUCTION
F.D.
F.D.
F.D.
F.D.
F.D. F.D.
ATTENUATION SOUND BLANKET
FE-1
FE-1
FE-1
FE-1
F.D.
F.D.
B
FIRE SHUTTER ABOVE
FE-1
camerst Callout
RPC ADDR=7
camerst Callout
RPC ADDR=8
camerst Callout
RPC ADDR=9
camerst Callout
RPC ADDR=8