36C24623Q0431.docx

DOCX document 25 KB Posted

Attached to
6515--MRI Patient Monitors Federal contract opportunity
Solicitation number
36C24623Q0431
Issued by
Department of Veterans Affairs Veterans Health Administration Veterans Integrated Service Network 6

View the file

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Sources Sought Notice Sources Sought Notice

SUBJECT*
MRI Patient Monitor

GENERAL INFORMATION

CONTRACTING OFFICE’S ZIP CODE*
28301
SOLICITATION NUMBER*
36C24623Q0431
RESPONSE DATE/TIME/ZONE
02-13-2023 8AM EASTERN TIME, NEW YORK, USA
ARCHIVE
14 DAYS AFTER THE RESPONSE DATE
RECOVERY ACT FUNDS
N

SET-ASIDE

PRODUCT SERVICE CODE*
6515
NAICS CODE*
334510

CONTRACTING OFFICE ADDRESS

Department of Veterans Affairs Network Contracting Office 6 201 Hay Street, Suite 304 Fayetteville NC 28301

POINT OF CONTACT*

Contracting Officer Isaac Hernandez Isaac.Hernandez@va.gov

(910) 488-2120 x: 5862

PLACE OF PERFORMANCE

ADDRESS
Durham VAMC

508 Fulton St.

Durham NC

POSTAL CODE
27705
COUNTRY
USA

ADDITIONAL INFORMATION

AGENCY’S URL
https://www.va.gov
URL DESCRIPTION
va.gov
AGENCY CONTACT’S EMAIL ADDRESS
Isaac.Hernandez@va.gov
EMAIL DESCRIPTION
va.gov

DESCRIPTION

Good Day, The Department of Veterans Affairs, Network Contracting Office (NCO) 6 on behalf of Durham VAMC is conducting Market Research through this sources sought notice to help determine the availability of qualified Businesses, capable of providing two (2) MRI patient monitors. The government is seeking that the MRI patient monitors be able to withstand a GAUSS of greater than 5 gauss (provide product max Gauss rating), any FDA approvals associated with the equipment, shall be able to measure EKG, SPO2, NBP, and A-line, allow for wireless monitoring of patients beyond the 5 Gauss line, have the ability to travel with the patient between ICU and MRI, cross compatibility with Phillips and Siemens equipment (ie: Ingenia 1.5T, Ingenia 3.0T, or Magnetom Aera), and any other features proprietary to your equipment.

All respondents shall indicate the following:

· Whether or not they are small business manufacturers of the products they wish to offer, or

· Is your company interested in providing a Federal Supply Schedule (FSS) quote or Open Market (indicate FSS contract #)?

· Identify any other companies owned (wholly or in-part) by the owners of this business who provide goods or services under the same or a related NAICS codes.

· Identify any other companies owned (wholly or in-part) by the owners of this business who provide goods or services that are registered under the same or a related NAICS code with the Center for Veterans Enterprise (CVE); Provide the certification type (SDVOSB/VOSB), Federal Identification Number, and state of incorporation for each.

· Do you plan on responding to a solicitation for this requirement with a Joint Venture utilizing multiple owned companies as majority or non-majority owner?

· Yes ___No ___ If yes, please identify which companies are considering a Joint Venture and the ownership of each company.

Failure to provide the above information may result in the potential offeror being considered incapable of meeting the VA’s needs

If the contractor can provide the above items, the contractor shall provide a letter from the manufacturer stating they are an authorized distributor/licenser of their products. Failure to submit an authorized distributor letter shall result in the product(s) potentially offered to be considered “grey market” and shall not be considered technically acceptable.

The capability statements received from this market research are for planning purposes only and will assist the Government in planning its acquisition strategy. This is strictly market research and the Government will not entertain questions concerning this market research. The Government will not assume any costs incurred by the contractor in the preparation of responses. All responses shall be submitted in writing no later than February 13th, at 0800AM EST to the attention of: Isaac.Hernandez@va.gov Please title the subject line for all responses as: Sources Sought MRI Patient Monitors: 36C24623Q0431.

*= Required Field
Sources Sought Notice

Sources Sought Notice

File details come from the government source that posted it. Updated .