36C24418B0586-002.pdf
PDF 10 MB Posted
- Attached to
- Make Fire Safety Improvements, NRM Project# 503-17-107 Federal contract opportunity
- Solicitation number
- 36C24418B0586
About this file
36C24418B0586 503-17-107 DRAWINGS COMBINED.pdf
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| 36C24418C0281-000.docx | DOCX document | |
| 36C24418B0586-0001001.docx | DOCX document | |
| 36C24418B0586-0001000.docx | DOCX document | |
| 36C24418B0586-004.docx | DOCX document | |
| 36C24418B0586-001.docx | DOCX document | |
| 36C24418B0586-006.docx | DOCX document | |
| 36C24418B0586-005.docx | DOCX document | |
| 36C24418B0586-003.pdf | ||
| 36C24418B0586-000.docx | DOCX document |
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
2907 PLEASANT VALLEY BLVD.
ALTOONA, PA
LOCATION MAP
Project Title
DE
PA
RT
M
EN
T
OF
VE
TE
RA
NS
A
FF
AI
RS
Drawing Title Date
Project No.
Drawing No.
Dwg. Of
Approved: Associate Director for Operations:
Approved: Director, Medical Center:
Drawn:Building No: Checked:
Location:
Additions:
Revisions:
1 5 6 7 8
21 3 4 5 6 7 8
A B
C D
E o n e q u a r t e r i n c h o n e f o o t o n e e i g h t h i n c e f o o t t h r e e e i g h t h s i n c e f o o t o n e h a l f i n c e f o o t o n e a n d o n e h a l f i n c e f o o t o n e i n c e f o o t t h r e e q u a r t e r s i n c e f o o t t h r e e i n c h e s e f o o t
DELLC
JOB No.
JAMES E. VAN ZANDT
VETERANS ADMINISTRATION
MEDICAL CENTER
2 3 4
Consultants:Date
Bel Air, Maryland 21015-1457
2215 Conowingo Rd, Suite 100 fax 410.836.6611
410.803.0009
ARCHITECTURE
PLANNING
ENGINEERING
100% CONSTRUCTION DOCUMENTS
FULLY SPRINKLERED
BUILDING COST CONSULTANTS
COST ESTIMATING
12917 - 30TH AVENUE
PLATTSMOUTH, NEBRASKA 68048
402.298.8260 - FAX 402.298.8290
FIRE PROTECTION ENGINEERING
8815 CENTRE PARK DR., SUITE 200
COLUMBIA, MARYLAND 21045
410.750.2246 - FAX 410.750.2588
KOFFEL ASSOCIATES, INC.
COVER SHEET MAKE FIRE SAFETY
IMPROVEMENTS
CDP/ CAJ WFPH/ DGW
06/26/2018
C-X-1
503-17-107
170703D
JAMES E. VAN ZANDT VETERANS
ADMINISTRATION MEDICAL CENTER
ALTOONA, PA.
MAKE FIRE SAFETY IMPROVEMENTS
PROJECT # 503-17-107
INDEX OF DRAWINGS
SHEET NO. SHEET NAME
00 GENERAL INFORMATION
C-X-1 COVER SHEET
C-X-2 SYMBOLS, ABBREVIATIONS & CODE
C-X-3 ALTOONA CAMPUS PLAN
04 ARCHITECTURE
1-B-1 BLDG 01 - BASEMENT REFLECTED CEILING PLAN - PART A
1-B-2 BLDG 01 - BASEMENT REFLECTED CEILING PLAN - PART B
1-B-3 BLDG 01 - BASEMENT REFLECTED CEILING PLANS - PART C & D
1-1-1 BLDG 01 - 1ST FLOOR - PART A
1-2-1 BLDG 01 - 2ND FLOOR - PARTS A, B & C
1-3-1 BLDG 01 - 3RD FLOOR PLAN - PART A & PART B
1-7-1 BLDG 01 - 7TH FLOOR PLAN
1 26
21 FIRE SUPRESSION
FP1 FIRE SUPRESSION NOTES, SYMBOLS AND ABBREVIATIONS
1-B-FP1 BASEMENT PART A - FIRE SUPRESSION
1-B-FP2 BASEMENT PART B - FIRE SUPRESSION
1-B-FP3 BASEMENT PART C - FIRE SUPRESSION
1-B-FP4
1-1-FP1 FIRST FLOOR PART A - FIRE SUPRESSION
1-1-FP2 FIRST FLOOR PART B - FIRE SUPRESSION
1-1-FP3 FIRST FLOOR PART C - FIRE SUPRESSION
1-1-FP4
1-2-FP1
1-2-FP2
BASEMENT PART D - FIRE SUPRESSION
FIRST FLOOR PART D - FIRE SUPRESSION
1-2-FP3
1-7-FP1
1-8-FP1
SECOND FLOOR PART A - FIRE SUPRESSION
SECOND FLOOR PART B - FIRE SUPRESSION
SECOND FLOOR PART C - FIRE SUPRESSION
SEVENTH FLOOR PLAN - FIRE SUPRESSION
EIGHTH FLOOR PLAN - FIRE SUPRESSION
FP2 DETAIL SHEET - FIRE SUPRESSION
A1 DETAIL SHEET - ARCHITECTURAL
concrete masonry unit demolish, demolition
CU cubic
DR
D
DS
DWG
DF
DIA
DTL
DL
DEM
DIM
door downspout drinking fountain drain drawing dead load diameter detail dimension
AUTO automatic cast iron column ceramic tile cement control joint construction concrete continuous, continue ceiling catch basin
COL
CJT
CONT
CONST
CONC
CMU
CI
CT
CEM
CLG
CB
basement below finish floor bearing plate both sides board block building bottom built up roof bench mark bituminous
BLK
BS
BD
BUR
BLDG
BOT
BFF
BPL
BSMT
BM
BIT
alternate air conditioning above finish floor asphalt anchor bolt architect (ural) approximate aluminum
ALT
AB
ARCH
APPROX.
ASPH
ALUM
AC
AFF
WC
water closet plaster air conditioning
PLAS
insulation insulated glass unit inside diameter include (d) (ing) hot water heater hose bib horizontal hollow metal hollow core interior
INCL
INSUL
IGU
ID
INT
HOR
HWH
HM
HB
HC
point plywood plate concrete plank-painted square inch pounds per square foot pounds per polyvinyl chloride
PSF
PSI
PL
PT
PVC
PWD
PLK
west, width, wide welded wire fabric waterproof (ing) wood base wired glass
WB
WG
WWF
WP
W/
W
WD
with wood manholeMH
EXP expansion, exposed galvanized hollow metal fire extinguisher cabinet
GA
galvanized gypsum wall board glazed masonry unit general contractor heating ventilating grade, grading hardware gypsum gauge
GWB
HVAC
HDW
GYP
GALV
GMU
GHM
GD
GC
fire extinguisher finish (ed) exterior finished floor line foundation footing floor drain floor (ing) flashingFLG
FLR
FND
FTG
FD
EXT
FFL
FEC
FE
FIN
nominalNOM north opening on center outside diameter perimeter panel polished float glass overhead overall not to scale not in contract
OD
PER
OH
OA
PNL
PFG
N
OC
OPG
NTS
NIC
marble masonry manufacture (er) maximum metal mechanical miscellaneous minimum medium medium density overlay masonry opening
MTL
MECH
MISC
MIN
MED
MAX
MBL
MAS
MFR
MDO
MO
emergency each way existing exhaust estimate electric water cooler elevation electric (al)
EST
EXH
EXIST
EMER
ELEV
EW
EWC
ELEC
knock out invert left hand lavatory
LBL
LH
LPL
LAV
label low presure laminate
JT
KO
INV
joint
RO rough opening
TBD to be determined tempered float glass tongue & groove thick (ness) vinyl covered drywall vinyl composition tile vertical
VCT
VCD
VERT
TYP typical
TFG
T&G
THK
schedule section specification (s) square straight structural storage south, switch (es) seamless floor
SPEC
ST
SQ
STR
STL
STO
steel
SIM
SEC
SCH
SF
S similar reference quarry tile property line right of way revision, revised return air
REF
ROW
REV
RM
R
RA
riser room
QT
PL
R radius
RCP reflected ceiling plan plastic laminateP-LAM
SYS system high pressure laminateHPL
LT light
ABBREVIATIONS
A301
A301
OT
GYM
10'-0"
A.F.F.
DETAIL TAG
COLUMN LINE BUBBLE TAG
CEILING HEIGHT TAG
A-?
DWG NAME
SCALE:
SECTION TAG
ROOM TAG - NEW WORK
WINDOW TAG
WALL TYPE TAG
TITLE TAG
W05
INTERIOR ELEVATION
EXTERIOR ELEVATION
ELEVATION MARK
DETAIL CALL OUT
TAG
REVISION TAG
FIRST FLOOR
DOOR TAG
CONSTRUCTION KEY
NOTE TAG
X
D1-202A
A201
A201
125 SF
STOREFRONT
WINDOW TAG
S05
INTERIOR
WINDOW TAG
i05 S05
STOREFRONT
WINDOW TAG - WIDE
BUILDING DATA AND CODE REVIEW
PROJECT NAME:VA ALTOONA - MAKE FIRE SAFETY IMPROVEMENTS
PROJECT LOCATION:
2907 PLEASANT VALLEY BOULEVARD
ALTOONA, PA 16602-4377
GENERAL DESCRIPTION:
APPLICABLE CODES:
SYMBOLS
- NFPA 101 LIFE SAFETY CODE 2015 EDITION
- NATIONAL ELECTRICAL CODE (NEC/NFPA 70)
- VA BARRIER FREE DESIGN GUIDE
- VA FIRE PROTECTION DESIGN MANUAL, SEVENTH EDITION - AUGUST 2018
BID SUMMARY
FIRE SAFETY IMPROVEMENTS TO THE VA ALTOONA ARE TO INCLUDE BUILDING 1:
THE BASEMENT, THE 1ST, 2ND, 3RD, AND 7TH FLOOR. EXTERIOR IMPROVEMENTS
ARE NOT LIMITED TO, BUT TO INCLUDE, A METAL ROOF TO REPLACE A WOODEN
ROOF, EXTERIOR SPRINKLERS, AND DEDUCT ALTERNATES LISTED BELOW.
BASE BID:
BID DEDUCTS:
DEDUCT
ALTERNATE 1:
LOCATED ON SHEET C-X-3. EXTERIOR SPRINKLERS TO BE INSTALLED THROUGH
EXTERIOR WALL; SEE ARCHITECTURAL DETAILS SHEET A1 FOR WEATHER
STOPPING, AND FIRE ENGINEER DRAWINGS 1-B-FP1, 1-B-FP4, AND 1-1-FP2 FOR
SPECIFIC LOCATIONS.
DEDUCT
ALTERNATE 3:
LOCATED ON SHEET 1-B-2. PAINT NEW SPRINKLER PIPE; SEE FIRE ENGINEERING
DRAWINGS 1-B-FP2 FOR LOCATION AND LENGTH TO BE PAINTED.
DEDUCT
ALTERNATE 4:
DEDUCT
ALTERNATE 5:
LOCATED ON SHEET 1-B-FP3. NEW SPRINKLER PIPE TO BE PAINTED.
DEDUCT
ALTERNATE 6:
LOCATED ON SHEET 1-B-FP4. NEW SPRINKLER PIPE TO BE PAINTED.
DEDUCT
ALTERNATE 7:
LOCATED ON SHEET 1-1-FP2. NEW SPRINKLER PIPE TO BE PAINTED.
DEDUCT
ALTERNATE 9:
LOCATED ON SHEET 1-1-FP3. NEW SPRINKLER PIPE TO BE PAINTED.
LOCATED ON SHEET 1-7-FP1. NEW SPRINKLER PIPE TO BE PAINTED.
DEDUCT
ALTERNATE 2:
LOCATED ON SHEET 1-7-FP1. NEW SPRINKLER PIPE TO BE PAINTED.
DEDUCT
ALTERNATE 8:
LOCATED ON SHEET 1-1-FP2. NEW SPRINKLER PIPE TO BE PAINTED.
Project Title
DE
PA
RT
M
EN
T
OF
VE
TE
RA
NS
A
FF
AI
RS
Drawing Title Date
Project No.
Drawing No.
Dwg. Of
Approved: Associate Director for Operations:
Approved: Director, Medical Center:
Drawn:Building No: Checked:
Location:
Additions:
Revisions:
1 5 6 7 8
21 3 4 5 6 7 8
A B
C D
E o n e q u a r t e r i n c e f o o t o n e e i g h t h i n c e f o o t t h r e e e i g h t h s i n c e f o o t o n e h a l f i n c e f o o t o n e a n d o n e h a l f i n c e f o o t o n e i n c e f o o t t h r e e q u a r t e r s i n c e f o o t t h r e e i n c h e e f o o t
DELLC
JOB No.
JAMES E. VAN ZANDT
VETERANS ADMINISTRATION
MEDICAL CENTER
2 3 4
Consultants:Date
Bel Air, Maryland 21015-1457
2215 Conowingo Rd, Suite 100 fax 410.836.6611
410.803.0009
ARCHITECTURE
PLANNING
ENGINEERING
100% CONSTRUCTION DOCUMENTS
FULLY SPRINKLERED
BUILDING COST CONSULTANTS
COST ESTIMATING
12917 - 30TH AVENUE
PLATTSMOUTH, NEBRASKA 68048
402.298.8260 - FAX 402.298.8290
FIRE PROTECTION ENGINEERING
8815 CENTRE PARK DR., SUITE 200
COLUMBIA, MARYLAND 21045
410.750.2246 - FAX 410.750.2588
KOFFEL ASSOCIATES, INC.
SYMBOLS, ABBREVIATIONS
& CODES
MAKE FIRE SAFETY
IMPROVEMENTS
CDP/ CAJ WFPH/ DGW
06/26/2018
C-X-2
503-17-107
170703D
2 26
BLDG. 01
CAYUGA
CIRCLE
Project Title
DE
PA
RT
M
EN
T
OF
VE
TE
RA
NS
A
FF
AI
RS
Drawing Title Date
Project No.
Drawing No.
Dwg. Of
Approved: Associate Director for Operations:
Approved: Director, Medical Center:
Drawn:Building No: Checked:
Location:
Additions:
Revisions:
1 5 6 7 8
21 3 4 5 6 7 8
A B
C D
E o n e q u a r t e r i n c e f o o t o n e e i g h t h i n c e f o o t t h r e e e i g h t h s i n c e f o o t o n e h a l f i n c e f o o t o n e a n d o n e h a l f i n c e f o o t o n e i n c e f o o t t h r e e q u a r t e r s i n c e f o o t t h r e e i n c h e e f o o t
DELLC
JOB No.
JAMES E. VAN ZANDT
VETERANS ADMINISTRATION
MEDICAL CENTER
2 3 4
Consultants:Date
Bel Air, Maryland 21015-1457
2215 Conowingo Rd, Suite 100 fax 410.836.6611
410.803.0009
ARCHITECTURE
PLANNING
ENGINEERING
100% CONSTRUCTION DOCUMENTS
FULLY SPRINKLERED
BUILDING COST CONSULTANTS
COST ESTIMATING
12917 - 30TH AVENUE
PLATTSMOUTH, NEBRASKA 68048
402.298.8260 - FAX 402.298.8290
FIRE PROTECTION ENGINEERING
8815 CENTRE PARK DR., SUITE 200
COLUMBIA, MARYLAND 21045
410.750.2246 - FAX 410.750.2588
KOFFEL ASSOCIATES, INC.
ALTOONA
CAMPUS PLAN
MAKE FIRE SAFETY
IMPROVEMENTS
CDP/ CAJ WFPH/ DGW
06/26/2018
C-X-3
503-17-107
170703D
SCALE: 1" = 50'
25' 50'0 100'
PLAN NORTH
TRUE NORTH
SCALE: 1/32" = 1'-0"C-X-3
1 EXIST ALTOONA CAMPUS PLAN
3 26
ALTOONA, PA
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text NEW WORK ITEMS EXTERIOR SPRINKLERS TO BE INSTALLED THROUGH EXTERIOR WALL; SEE ARCHITECTURAL DETAILS SHEET A1 FOR WEATHER STOPPING, AND FIRE ENGINEERING DRAWINGS FOR LOCATIONS.
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text EXTERIOR SPRINKLERS TO BE INSTALLED THROUGH EXTERIOR WALL; SEE ARCHITECTURAL DETAILS SHEET A1 FOR WEATHER STOPPING, AND FIRE ENGINEERING DRAWINGS FOR LOCATIONS. (DEDUCT ALTERNATE #1)
AutoCAD SHX Text DEMO EXISTING WOOD ROOF, REPLACE WITH METAL STANDING SEAM ROOF. SEE ARCHITECTURAL DETAILS SHEET A1 FOR DETAILS.
MAIL ROOM
MECHANICAL ROOM
LOBBY
27A
ELECTRICAL ROOM
CHIEF V&R OFFICE
ELECTRICAL SHOP
STORAGE
BATHROOM
26A
PAINT SHOP
PLUMBING SHOP
MACHINE SHOP
CARPENTER SHOP
LOCKSMITH
22A
MECHANICAL ROOM
LOCKER ROOM
17A
MENS TLT EMS
16A
STORAGE VCS
17B
COOLER
17C
STORAGE MAS
29A
STORAGE MAS
BIO-MED SHOP
STORAGE A&MM
EMERGENCY
WHEELCHAIR
32A
SIGN SHOP
CL
CL
STAIR
S000
STAIR
S002
EMERGENCY
WHEELCHAIR
32A
SIGN SHOP
CL
RETAIL STORE
RETAIL STORAGE
1A
Project Title
DE
PA
RT
M
EN
T
OF
VE
TE
RA
NS
A
FF
AI
RS
Drawing Title Date
Project No.
Drawing No.
Dwg. Of
Approved: Associate Director for Operations:
Approved: Director, Medical Center:
Drawn:Building No: Checked:
Location:
Additions:
Revisions:
1 5 6 7 8
21 3 4 5 6 7 8
A B
C D
E o n e q u a r t e r i n c e f o o t o n e e i g h t h i n c e f o o t t h r e e e i g h t h s i n c e f o o t o n e h a l f i n c e f o o t o n e a n d o n e h a l f i n c e f o o t o n e i n c e f o o t t h r e e q u a r t e r s i n c e f o o t t h r e e i n c h e e f o o t
DELLC
JOB No.
JAMES E. VAN ZANDT
VETERANS ADMINISTRATION
MEDICAL CENTER
2 3 4
Consultants:Date
Bel Air, Maryland 21015-1457
2215 Conowingo Rd, Suite 100 fax 410.836.6611
410.803.0009
ARCHITECTURE
PLANNING
ENGINEERING
100% CONSTRUCTION DOCUMENTS
FULLY SPRINKLERED
BUILDING COST CONSULTANTS
COST ESTIMATING
12917 - 30TH AVENUE
PLATTSMOUTH, NEBRASKA 68048
402.298.8260 - FAX 402.298.8290
FIRE PROTECTION ENGINEERING
8815 CENTRE PARK DR., SUITE 200
COLUMBIA, MARYLAND 21045
410.750.2246 - FAX 410.750.2588
KOFFEL ASSOCIATES, INC.
BLDG 01 - BASEMENT
FLOOR - PART A
REFLECTED CEILING PLAN
MAKE FIRE SAFETY
IMPROVEMENTS
CDP/ CAJ WFPH/ DGW
06/26/2018
1-B-1
503-17-107
170703D
SCALE: 1/8" = 1'-0"1-B-1
BASEMENT FLOOR - PART A
REFLECTED CEILING PLAN
PLAN NORTH
TRUE NORTHSCALE: 1/8" = 1'-0"
4'-0"8'-0"0 16'-0"
4 26
ALTOONA, PA
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text NEW WORK ITEMS PATCH AND PAINT LATH AND PLASTER TO MATCH EXISTING AS REQUIRED FOLLOWING NECESSARY WORK; SEE FIRE ENGINEER DRAWING 1-B-FP1 FOR LOCATION. REMOVE EXISTING CEILING AS REQUIRED FOR FIRE PROTECTION WORK ABOVE CEILING. REINSTALL CEILING TO ORIGINAL CONDITION FOLLOWING NECESSARY WORK (SEE FIRE ENGINEERING DRAWING 1-2-FP1). REMOVE EXISTING CEILING AS REQUIRED FOR FIRE PROTECTION WORK ABOVE CEILING. REINSTALL CEILING TO ORIGINAL CONDITION FOLLOWING NECESSARY WORK (SEE FIRE ENGINEERING DRAWING 1-2-FP2). REMOVE EXISTING CEILING AS REQUIRED FOR FIRE PROTECTION WORK ABOVE CEILING. REINSTALL CEILING TO ORIGINAL CONDITION FOLLOWING NECESSARY WORK (SEE FIRE ENGINEERING DRAWING 1-2-FP3). REMOVE EXISTING CEILING AS REQUIRED FOR FIRE PROTECTION WORK ABOVE CEILING. REINSTALL CEILING TO ORIGINAL CONDITION FOLLOWING NECESSARY WORK (SEE FIRE ENGINEERING DRAWING 1-B-FP1). REPLACE CEILING TILE TO MATCH EXISTING FOLLOWING NECESSARY WORK (SEE FIRE ENGINEERING DRAWING 1-B-FP4 FOR LOCATION). PAINT NEW SPRINKLER PIPE; SEE FIRE ENGINEERING DRAWING 1-1-FP3 FOR LOCATION AND LENGTH TO BE PAINTED. PAINT NEW SPRINKLER PIPE; SEE FIRE ENGINEERING DRAWINGS 1-B-FP2 FOR LOCATION AND LENGTH TO BE PAINTED. 6 TOTAL 8" PENETRATIONS. SEAL PIPE PENETRATIONS WITH 2 HOUR RATED FIRE SEAL. 6 TOTAL 8" PENETRATIONS. SEAL PIPE PENETRATIONS WITH 1 HOUR RATED FIRE SEAL. 11 TOTAL SMOKE BARRIER PENETRATIONS, AROUND ~6" PIPES; SEAL ALL PENETRATIONS WITH SMOKE TIGHT SEALANT. TWO (2) 1' SMOKE BARRIER PENETRATIONS, SEAL ALL PENETRATIONS WITH SMOKE TIGHT SEALANT. 18"x8' SMOKE BARRIER PENETRATION AROUND INSULATED PIPES, SEAL PENETRATION WITH SMOKE TIGHT SEALANT. 12"x14" SMOKE BARRIER PENETRATION, SEAL WITH SMOKE TIGHT SEALANT. 2"x5" PNEUMATIC TUBE SMOKE BARRIER PENETRATION, SEAL WITH SMOKE TIGHT SEALANT. 24"x42" DUCT SURROUND SMOKE BARRIER PENETRATION, SEAL WITH SMOKE TIGHT SEALANT. 6" DIAMETER SMOKE BARRIER PENETRATION AROUND CONDUIT, SEAL WITH SMOKE TIGHT SEALANT. THREE (3) SMOKE BARRIER PENETRATIONS - 10", 14" 14"; SEAL WITH SMOKE TIGHT SEALANT. THREE (3) SMOKE BARRIER PENETRATIONS - 7", 10", 12"; SEAL WITH SMOKE TIGHT SEALANT. DEMO EXISTING PASS-THROUGH WINDOW AND COUNTER. INSTALL NEW PHARMACY WINDOW WITH INTEGRAL DRAWER; INTERBANK EQUIPMENT, LLC 'Q-TRAN-1019 TRANSACTION STATION' OR SIMILAR. SEE DETAIL 3 ON SHEET 1-1-1. ONE (1) 8" PENETRATION; 2 HOUR FIRE SEAL PIPE PENETRATION. INSTALL MOTION SENSOR AND PUSH TO EXIT BUTTON. RELOCATE EXISTING PUSH TO EXIT BUTTON. INSTALL PUSH TO EXIT BUTTON 56" FROM INSIDE CORNER. SET PUSH TO EXIT LOCK TIMER TO 30 SECONDS OR GREATER. 10"X20" GALVANIZED DUCT FIRE BARRIER PENETRATION; INSTALL FIRE DAMPER IN DUCT. 50"x40" OPENING AROUND DUCT PENETRATION IN 2 HOUR FIRE RATED WALL. INSTALL FIRE BLOCK TO SEAL PENETRATION. PATCH CMU AFTER SPRINKLER DEMO, REFER TO FIRE ENGINEERING DRAWINGS FOR DEMO AND LOCATION THREE (3) 4" FIRE BARRIER PENETRATIONS; SEAL PENETRATION WITH 2 HOUR RATED FIRE SEAL ONE (1) 6"x12" PENETRATION; SEAL PENETRATION WITH SMOKE TIGHT SEALANT. REMOVE EXISTING CEILING TILE AS REQUIRED FOR ARCHITECTURAL WORK ABOVE CEILING. REINSTALL CEILING TO ORIGINAL CONDITION FOLLOWING NECESSARY WORK. EXTERIOR SPRINKLERS TO BE INSTALLED THROUGH EXTERIOR WALL. SEE ARCHITECTURAL DETAILS SHEET A1 FOR WEATHER STOPPING, AND FIRE ENGINEERING DRAWING 1-B-FP1. PAINT NEW SPRINKLER PIPE; SEE FIRE ENGINEERING DRAWING 1-B-FP4. REMOVE EXISTING CEILING TILE AS REQUIRED FOR FIRE PROTECTION WORK ABOVE CEILING. REINSTALL TO FINAL CONDITION FOLLOWING NECESSARY WORK (SEE FIRE ENGINEERING DRAWING 20-1-FP1). EXTERIOR SPRINKLERS TO BE INSTALLED THROUGH EXTERIOR WALL. SEE ARCHITECTURAL DETAILS SHEET A1 FOR WEATHER STOPPING, AND FIRE ENGINEER DRAWING 1-2-FP2. EXTERIOR SPRINKLERS TO BE INSTALLED THROUGH EXTERIOR WALL. SEE ARCHITECTURAL DETAILS SHEET A1 FOR SEE ARCHITECTURAL DETAILS SHEET A1 FOR WEATHER STOPPING, AND FIRE ENGINEER DRAWING 1-B-FP2. DRYWALL SEAMS AND SMOKE BARRIER PENETRATION FROM INCOMPLETE/CURRENT CONSTRUCTION/ICRA BARRIER. REMOVE EXISTING CEILING AS REQUIRED FOR FIRE PROTECTION WORK ABOVE CEILING. REINSTALL CEILING TO ORIGINAL CONDITION FOLLOWING NECESSARY WORK (SEE FIRE ENGINEERING DRAWING 1-1-FP3).
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text A
AutoCAD SHX Text C
AutoCAD SHX Text D
AutoCAD SHX Text B
AutoCAD SHX Text
AutoCAD SHX Text
AREAS NOT INCLUDED IN ARCHITECTURAL SCOPE OF WORK
AutoCAD SHX Text
2 HOUR FIRE BARRIER
AutoCAD SHX Text
FIRE & SMOKE BARRIER LEGEND
AutoCAD SHX Text
1 HOUR FIRE BARRIER
AutoCAD SHX Text
2 HOUR FIRE SMOKE BARRIER
AutoCAD SHX Text
30 MIN SMOKE BARRIER
AutoCAD SHX Text
A ELECTRICAL ROOM 19 - PENETRATIONS, TYP.
AutoCAD SHX Text
B MECHANICAL ROOM 18, PENETRATIONS, TYP.
AutoCAD SHX Text
C MAIL ROOM 29 - PENETRATIONS, TYP.
AutoCAD SHX Text
D SIGN SHOP 33, PENETRATIONS, TYP.
AutoCAD SHX Text 1 16'X4' SMOKE BARRIER PENETRATION (ENTIRE LENGTH OF WALL); DEMO EXISTING AS NECESSARY, 16'X4' SMOKE BARRIER PENETRATION (ENTIRE LENGTH OF WALL); DEMO EXISTING AS NECESSARY, SEAL PENETRATION WITH FIRE RATED GYP. AND STUDS 16" O.C. AS REQUIRED. SEAL PENETRATION WITH FIRE RATED GYP. AND STUDS 16" O.C. AS REQUIRED. SEAL ANY NEW OR EXISTING GYP PENETRATIONS WITH SMOKE TIGHT SEALANT. 2 REMOVE EXISTING CEILING TILE AS REQUIRED FOR FIRE PROTECTION WORK ABOVE CEILING. REMOVE EXISTING CEILING TILE AS REQUIRED FOR FIRE PROTECTION WORK ABOVE CEILING. REINSTALL CEILING TO ORIGINAL CONDITION FOLLOWING NECESSARY WORK. (SEE FIRE ENGINEERING DRAWING 1-B-FP1) 3 TWO (2) 1' SMOKE BARRIER PENETRATIONS, SEAL ALL PENETRATIONS WITH SMOKE TIGHT SEALANT. TWO (2) 1' SMOKE BARRIER PENETRATIONS, SEAL ALL PENETRATIONS WITH SMOKE TIGHT SEALANT. 4 18" X 8" SMOKE BARRIER PENETRATION AROUND INSULATED PIPES, SEAL PENETRATION WITH 18" X 8" SMOKE BARRIER PENETRATION AROUND INSULATED PIPES, SEAL PENETRATION WITH PENETRATION WITH SMOKE TIGHT SEALANT. 5 11 TOTAL SMOKE BARRIER PENETRATIONS, AROUND 6" PIPES; SEAL ALL PENETRATIONS WITH SMOKE 11 TOTAL SMOKE BARRIER PENETRATIONS, AROUND 6" PIPES; SEAL ALL PENETRATIONS WITH SMOKE TIGHT SEALANT. 6 11 TOTAL 1 HR FIRE BARRIER PENETRATIONS, AROUND 6" PIPES; SEAL ALL PENETRATIONS WITH 1 11 TOTAL 1 HR FIRE BARRIER PENETRATIONS, AROUND 6" PIPES; SEAL ALL PENETRATIONS WITH 1 HOUR RATED FIRE SEAL. 7 11 TOTAL 2 HR FIRE BARRIER PENETRATIONS, AROUND 6" PIPES; SEAL ALL PENETRATIONS WITH 2 11 TOTAL 2 HR FIRE BARRIER PENETRATIONS, AROUND 6" PIPES; SEAL ALL PENETRATIONS WITH 2 HOUR RATED FIRE SEAL. 8 12" x 14" SMOKE BARRIER PENETRATION, SEAL WITH SMOKE TIGHT SEALANT. 12" x 14" SMOKE BARRIER PENETRATION, SEAL WITH SMOKE TIGHT SEALANT. 9 2" x 5" PNEUMATIC TUBE SMOKE BARRIER PENETRATION, SEAL WITH SMOKE TIGHT SEALANT. 2" x 5" PNEUMATIC TUBE SMOKE BARRIER PENETRATION, SEAL WITH SMOKE TIGHT SEALANT. 10 24" x 42" DUCT SURROUND SMOKE BARRIER PENETRATION, SEAL WITH SMOKE TIGHT SEALANT. 24" x 42" DUCT SURROUND SMOKE BARRIER PENETRATION, SEAL WITH SMOKE TIGHT SEALANT. 11 6" DIAMETER SMOKE BARRIER PENETRATION AROUND CONDUIT, SEAL WITH SMOKE TIGHT SEALANT. 6" DIAMETER SMOKE BARRIER PENETRATION AROUND CONDUIT, SEAL WITH SMOKE TIGHT SEALANT. 12 EXTERIOR SPRINKLERS TO BE INSTALLED THROUGH EXTERIOR WALL. SEE A ARCHITECTURAL EXTERIOR SPRINKLERS TO BE INSTALLED THROUGH EXTERIOR WALL. SEE A ARCHITECTURAL A ARCHITECTURAL ARCHITECTURAL DETAILS SHEET A1 FOR WEATHER STOPPING, AND FIRE ENGINEERING DRAWING 1-B-FP1. 13 REMOVE EXISTING CEILING TILE AS REQUIRED FOR ARCHITECTURAL WORK ABOVE CEILING. REINSTALL REMOVE EXISTING CEILING TILE AS REQUIRED FOR ARCHITECTURAL WORK ABOVE CEILING. REINSTALL CEILING TO ORIGINAL CONDITION FOLLOWING NECESSARY WORK.
AutoCAD SHX Text
NEW WORK ITEMS
AutoCAD SHX Text PHASING NOTES: ALL WORK THIS SHEET TO BE DONE DURING DAYLIGHT HOURS EXCEPT FOR STAIR S002, WHICH IS TO BE DONE AFTER-HOURS.
GENERAL NOTE: PENETRATIONS SHALL BE PROPERLY FIRE SEALED WITH UL APPROVED FIRE SEAL. ANY PENETRATION WITH EXISTING NON-APPROVED FIRE SEAL, FIRE SEALANT, SHALL BE REMOVED AND REPLACED WITH NEW UL APPROVED FIRE SEALANT.
ELEVATOR ROOM
MECHANICAL ROOM
MECHANICAL PIT
POLICE TRAINING
Room
CHAIN LINK FENCE
CHAIN LINK FENCE
CHAIN LINK FENCE
STAIR
S104
Project Title
DE
PA
RT
M
EN
T
OF
VE
TE
RA
NS
A
FF
AI
RS
Drawing Title Date
Project No.
Drawing No.
Dwg. Of
Approved: Associate Director for Operations:
Approved: Director, Medical Center:
Drawn:Building No: Checked:
Location:
Additions:
Revisions:
1 5 6 7 8
21 3 4 5 6 7 8
A B
C D
E o n e q u a r t e r i n c e f o o t o n e e i g h t h i n c e f o o t t h r e e e i g h t h s i n c e f o o t o n e h a l f i n c e f o o t o n e a n d o n e h a l f i n c e f o o t o n e i n c e f o o t t h r e e q u a r t e r s i n c e f o o t t h r e e i n c h e e f o o t
DELLC
JOB No.
JAMES E. VAN ZANDT
VETERANS ADMINISTRATION
MEDICAL CENTER
2 3 4
Consultants:Date
Bel Air, Maryland 21015-1457
2215 Conowingo Rd, Suite 100 fax 410.836.6611
410.803.0009
ARCHITECTURE
PLANNING
ENGINEERING
100% CONSTRUCTION DOCUMENTS
FULLY SPRINKLERED
BUILDING COST CONSULTANTS
COST ESTIMATING
12917 - 30TH AVENUE
PLATTSMOUTH, NEBRASKA 68048
402.298.8260 - FAX 402.298.8290
FIRE PROTECTION ENGINEERING
8815 CENTRE PARK DR., SUITE 200
COLUMBIA, MARYLAND 21045
410.750.2246 - FAX 410.750.2588
KOFFEL ASSOCIATES, INC.
BLDG 01 - BASEMENT
FLOOR - PART B
REFLECTED CEILING PLAN
MAKE FIRE SAFETY
IMPROVEMENTS
CDP/ CAJ WFPH/ DGW
06/26/2017
1-B-2
503-17-107
170703D
SCALE: 1/8" = 1'-0"1-B-2
BASEMENT FLOOR PART B
REFLECTED CEILING PLAN
PLAN NORTH
TRUE NORTHSCALE: 1/8" = 1'-0"
4'-0"8'-0"0 16'-0"
5 26
ALTOONA, PA
B
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
FREIGHT ELEVATOR
AutoCAD SHX Text
AREAS NOT INCLUDED IN ARCHITECTURAL SCOPE OF WORK
AutoCAD SHX Text
2 HOUR FIRE BARRIER
AutoCAD SHX Text
FIRE & SMOKE BARRIER LEGEND
AutoCAD SHX Text
1 HOUR FIRE BARRIER
AutoCAD SHX Text
2 HOUR FIRE SMOKE BARRIER
AutoCAD SHX Text
30 MIN SMOKE BARRIER
AutoCAD SHX Text 1 NEW SPRINKLER TO BE INSTALLED THROUGH EXTERIOR WALL. SEE NEW SPRINKLER TO BE INSTALLED THROUGH EXTERIOR WALL. SEE ARCHITECTURAL DETAILS SHEET A1 FOR WEATHER STOPPING, AND FIRE ENGINEERING DRAWING 1-B-FP2. 2 PAINT NEW SPRINKLER PIPE; SEE FIRE ENGINEERING DRAWINGS 1-B-FP2 FOR PAINT NEW SPRINKLER PIPE; SEE FIRE ENGINEERING DRAWINGS 1-B-FP2 FOR LOCATION AND LENGTH TO BE PAINTED. (DEDUCT ALTERNATE #2)
AutoCAD SHX Text
PHASING NOTES: ALL WORK THIS SHEET TO BE DONE DURING DAYLIGHT HOURS.
AutoCAD SHX Text
NEW WORK ITEMS
GENERAL NOTE: PENETRATIONS SHALL BE PROPERLY FIRE SEALED WITH UL APPROVED FIRE SEAL. ANY PENETRATION WITH EXISTING NON-APPROVED FIRE SEAL, FIRE SEALANT, SHALL BE REMOVED AND REPLACED WITH NEW UL APPROVED FIRE SEALANT.
Room
STORAGE A&MM
STORAGE VCS
STORAGE A&MM
CANTEEN OFFICE
41D
COMPUTER ROOM
41C
MECHANICAL ROOM
EC
36A
Room 1B
HSK ROOM
41A
HAC ROOM
UNEXCAVATED
37A
STORAGE
LOCKER RM
Room
LOCKER RM
CH OFFICE VCS
A/C SHOP ENG SVC
STORAGE VCS
CREDIT UNION
OFFICE
CREDIT UNION
CREDIT UNION
OFFICE
BATH
DINING RM VCS
LOCKER RM
STAIR
S003
Project Title
DE
PA
RT
M
EN
T
OF
VE
TE
RA
NS
A
FF
AI
RS
Drawing Title Date
Project No.
Drawing No.
Dwg. Of
Approved: Associate Director for Operations:
Approved: Director, Medical Center:
Drawn:Building No: Checked:
Location:
Additions:
Revisions:
1 5 6 7 8
21 3 4 5 6 7 8
A B
C D
E o n e q u a r t e r i n c e f o o t o n e e i g h t h i n c e f o o t t h r e e e i g h t h s i n c e f o o t o n e h a l f i n c e f o o t o n e a n d o n e h a l f i n c e f o o t o n e i n c e f o o t t h r e e q u a r t e r s i n c e f o o t t h r e e i n c h e e f o o t
DELLC
JOB No.
JAMES E. VAN ZANDT
VETERANS ADMINISTRATION
MEDICAL CENTER
2 3 4
Consultants:Date
Bel Air, Maryland 21015-1457
2215 Conowingo Rd, Suite 100 fax 410.836.6611
410.803.0009
ARCHITECTURE
PLANNING
ENGINEERING
100% CONSTRUCTION DOCUMENTS
FULLY SPRINKLERED
BUILDING COST CONSULTANTS
COST ESTIMATING
12917 - 30TH AVENUE
PLATTSMOUTH, NEBRASKA 68048
402.298.8260 - FAX 402.298.8290
FIRE PROTECTION ENGINEERING
8815 CENTRE PARK DR., SUITE 200
COLUMBIA, MARYLAND 21045
410.750.2246 - FAX 410.750.2588
KOFFEL ASSOCIATES, INC.
BLDG 01 - BASEMENT
FLOOR - PART C & PART D
REFLECTED CEILING PLANS
MAKE FIRE SAFETY
IMPROVEMENTS
CDP/ CAJ WFPH/ DGW
06/26/2018
1-B-3
503-17-107
170703D
SCALE: 1/8" = 1'-0"1-B-3
BASEMENT FLOOR - PART C
REFLECTED CEILING PLAN
PLAN NORTH
TRUE NORTHSCALE: 1/8" = 1'-0"
4'-0"8'-0"0 16'-0"
6 26
SCALE: 1/8" = 1'-0"1-B-3
BASEMENT FLOOR - PART D
REFLECTED CEILING PLAN
ALTOONA, PA
C
D
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AREAS NOT INCLUDED IN ARCHITECTURAL SCOPE OF WORK
AutoCAD SHX Text
AutoCAD SHX Text
2 HOUR FIRE BARRIER
AutoCAD SHX Text
FIRE & SMOKE BARRIER LEGEND
AutoCAD SHX Text
1 HOUR FIRE BARRIER
AutoCAD SHX Text
2 HOUR FIRE SMOKE BARRIER
AutoCAD SHX Text
30 MIN SMOKE BARRIER
AutoCAD SHX Text
E MECHANICAL ROOM 36 - PENETRATIONS, TYP.
AutoCAD SHX Text 1 PAINT NEW SPRINKLER PIPE; SEE FIRE ENGINEERING DRAWINGS 1-B-FP3 FOR PAINT NEW SPRINKLER PIPE; SEE FIRE ENGINEERING DRAWINGS 1-B-FP3 FOR LOCATION AND LENGTH TO BE PAINTED 2 6" DIAMETER SMOKE BARRIER PENETRATION AROUND CONDUIT, SEAL WITH 6" DIAMETER SMOKE BARRIER PENETRATION AROUND CONDUIT, SEAL WITH SMOKE TIGHT SEALANT. 3 THREE (3) SMOKE BARRIER PENETRATION- 10", 14" & 14;" SEAL WITH SMOKE THREE (3) SMOKE BARRIER PENETRATION- 10", 14" & 14;" SEAL WITH SMOKE TIGHT SEALANT 4 THREE (3) SMOKE BARRIER PENETRATION- 7", 10" & 12"; SEAL WITH SMOKE THREE (3) SMOKE BARRIER PENETRATION- 7", 10" & 12"; SEAL WITH SMOKE TIGHT SEALANT. 5 REMOVE EXISTING CEILING TILE AS REQUIRED FOR FIRE PROTECTION WORK REMOVE EXISTING CEILING TILE AS REQUIRED FOR FIRE PROTECTION WORK ABOVE CEILING. REINSTALL CEILING TO ORIGINAL CONDITION FOLLOWING NECESSARY WORK. (SEE FIRE ENGINEERING DRAWING 1-B-FP4)
AutoCAD SHX Text
NEW WORK ITEMS
AutoCAD SHX Text
PHASING NOTES: ALL WORK THIS SHEET TO BE DONE DURING DAYLIGHT HOURS.
GENERAL NOTE: PENETRATIONS SHALL BE PROPERLY FIRE SEALED WITH UL APPROVED FIRE SEAL. ANY PENETRATION WITH EXISTING NON-APPROVED FIRE SEAL, FIRE SEALANT, SHALL BE REMOVED AND REPLACED WITH NEW UL APPROVED FIRE SEALANT.
CLERK
152A
CLERK
OFFICE
156D
SEC
OFFICE
156C
SUPERVISOR
PHARMACY
E L
E V
A T
O R
S
SUPERVISOR
CONSULT
156A
OFFICE
156C
CONSULT
156B RX PICKUP
RX PICKUP
OT GYM
B121
ADL
B120
OT EX/TRT/OFF
B108
OT EX/TRT/OFF
B109
STF TLT
B110
UNISEX TLT
B111
SOILED LAUNDRY
B112
PT OFFICE
P118OT OFFICE
B119
HYDRO THERAPY
B117
PT GYM
B113
PT EX/TRT/OFFICE
B116
PT EX/TRT/OFFICE
B115
PT EX/TRT/OFFICE
B114
CLINIC
C128 EXAM TX RM
C132
EXAM TX RM
C133
EMG/EXAM RM
C134
STORAGE
C125
PROSTEHETICS
PRINT ROOM
C139
STAFF TOILET
C138
BREAK RM
C137
SU
C135
MEDS
C136
PROST. OFFICE
C122
PROST. OFFICE
C121
PROST. OFFICE
C120
PROST. OFFICE
C119
PROST. OFFICE
C118
PROST. OFFICE
C117
SUPERVISOR
PROSTHETICS
OFFICE
C116
PROSTHETICS FILING
ROOM
C114
SPEECH
PATHOLOGIST
C113
CLINICAL OFFICE
C112
CLINICAL OFFICE
C111
CLEAN SUPPLY/02
STORAGE
C110
Project Title
DE
PA
RT
M
EN
T
OF
VE
TE
RA
NS
A
FF
AI
RS
Drawing Title Date
Project No.
Drawing No.
Dwg. Of
Approved: Associate Director for Operations:
Approved: Director, Medical Center:
Drawn:Building No: Checked:
Location:
Additions:
Revisions:
1 5 6 7 8
21 3 4 5 6 7 8
A B
C D
E o n e q u a r t e r i n c e f o o t o n e e i g h t h i n c e f o o t t h r e e e i g h t h s i n c e f o o t o n e h a l f i n c e f o o t o n e a n d o n e h a l f i n c e f o o t o n e i n c e f o o t t h r e e q u a r t e r s i n c e f o o t t h r e e i n c h e e f o o t
DELLC
JOB No.
JAMES E. VAN ZANDT
VETERANS ADMINISTRATION
MEDICAL CENTER
2 3 4
Consultants:Date
Bel Air, Maryland 21015-1457
2215 Conowingo Rd, Suite 100 fax 410.836.6611
410.803.0009
ARCHITECTURE
PLANNING
ENGINEERING
100% CONSTRUCTION DOCUMENTS
FULLY SPRINKLERED
BUILDING COST CONSULTANTS
COST ESTIMATING
12917 - 30TH AVENUE
PLATTSMOUTH, NEBRASKA 68048
402.298.8260 - FAX 402.298.8290
FIRE PROTECTION ENGINEERING
8815 CENTRE PARK DR., SUITE 200
COLUMBIA, MARYLAND 21045
410.750.2246 - FAX 410.750.2588
KOFFEL ASSOCIATES, INC.
BLDG 01 - 1ST FLOOR PLAN &
REFLECTED CEILING PLAN-
PART A
MAKE FIRE SAFETY
IMPROVEMENTS
CDP/ CAJ WFPH/ DGW
06/26/2018
1-1-1
503-17-107
170703D
PLAN NORTH
TRUE NORTH
SCALE: 1/8" = 1'-0"
4'-0"8'-0"0 16'-0"
SCALE: 1/8" = 1'-0"1-1-1
1 1ST FLOOR PLAN - PART A
7 26
SCALE: 1/8" = 1'-0"1-1-1
1ST FLOOR REFLECTED CEILING PLAN - PART B
SCALE: 1/2" = 1'-0"1-1-1
RX PICKUP WINDOW, NEW TRANSACTION STATION - ELEVATION
SCALE: 1/8" = 1'-0"1-1-1
1ST FLOOR PLAN - PART C
ALTOONA, PA
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AREAS NOT INCLUDED IN ARCHITECTURAL SCOPE OF WORK
AutoCAD SHX Text
AutoCAD SHX Text
2 HOUR FIRE BARRIER
AutoCAD SHX Text
FIRE & SMOKE BARRIER LEGEND
AutoCAD SHX Text
1 HOUR FIRE BARRIER
AutoCAD SHX Text
2 HOUR FIRE SMOKE BARRIER
AutoCAD SHX Text
30 MIN SMOKE BARRIER
AutoCAD SHX Text
STAINLESS STEEL COUNTERTOP
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text NEW WORK NOTES 1 DEMO EXISTING ROLL-DOWN GATE, PASS-THROUGH WINDOW AND TRANSACTION COUNTER. DEMO EXISTING ROLL-DOWN GATE, PASS-THROUGH WINDOW AND TRANSACTION COUNTER. 2 INSTALL NEW PHARMACY WINDOW WITH INTEGRAL DRAWER; INTERBANK EQUIPMENT, LLC 'Q-TRAN-1019 TRANSACTION STATION' INSTALL NEW PHARMACY WINDOW WITH INTEGRAL DRAWER; INTERBANK EQUIPMENT, LLC 'Q-TRAN-1019 TRANSACTION STATION' OR APPROVED EQUAL WITH BULLET-PROOF GLASS AND SPEAK THROUGH. SEE DETAIL 3 ON SHEET 1-1-1. 3 PROVISION TO BRING CREDIT CARD READER PLUG THROUGH WALL (JACK). PROVISION TO BRING CREDIT CARD READER PLUG THROUGH WALL (JACK). 4 REMOVE EXISTING CEILING AS REQUIRED FOR FIRE PROTECTION WORK ABOVE CEILING. REINSTALL CEILING TO ORIGINAL REMOVE EXISTING CEILING AS REQUIRED FOR FIRE PROTECTION WORK ABOVE CEILING. REINSTALL CEILING TO ORIGINAL CONDITION FOLLOWING NECESSARY WORK (SEE FIRE ENGINEERING DRAWING 1-1-FP3).
AutoCAD SHX Text 5 REMOVE EXISTING CEILING AS REQUIRED FOR FIRE PROTECTION WORK ABOVE CEILING. REMOVE EXISTING CEILING AS REQUIRED FOR FIRE PROTECTION WORK ABOVE CEILING. REINSTALL CEILING TO ORIGINAL CONDITION FOLLOWING NECESSARY WORK (SEE FIRE CEILING TO ORIGINAL CONDITION FOLLOWING NECESSARY WORK (SEE FIRE WORK (SEE FIRE ENGINEERING DRAWING 1-1-FP4).
AutoCAD SHX Text PHASING NOTES: ALL PART A WORK THIS SHEET TO BE DONE DURING NIGHTS AND WEEKENDS; PART B TO BE DONE DURING DAYLIGHT HOURS.
AutoCAD SHX Text
6 SEE DETAIL 3 ON SHEET 1-1-1.SEE DETAIL 3 ON SHEET 1-1-1.
AutoCAD SHX Text 7 STAINLESS STEEL COUNTERTOP TO BE INSTALLED.STAINLESS STEEL COUNTERTOP TO BE INSTALLED.
AutoCAD SHX Text A
AutoCAD SHX Text B
AutoCAD SHX Text C
GENERAL NOTE: PENETRATIONS SHALL BE PROPERLY FIRE SEALED WITH UL APPROVED FIRE SEAL. ANY PENETRATION WITH EXISTING NON-APPROVED FIRE SEAL, FIRE SEALANT, SHALL BE REMOVED AND REPLACED WITH NEW UL APPROVED FIRE SEALANT.
RECYCLE & TRASH
W208
TLT
W207
RED BAG STORAGE
W232C CLEANING SUPPLY
FOOD FREEZER
FREEZER
TLT
OFFICE
BREAK ROOM
INGREDIENT
STORAGE
STAIR
S200
FOOD SERVICE -
KITCHEN
FREEZER
229A
ED SPACE
CONTROL RM
ED SPACE OFFICE
256C
OFFICE
256B
TLT
253F
TLT
253E
WAITING RM
253D
LIBRARY
WORK RM
256A
LAB
253G
PHILOBTOMY
253H
CHEMISTRY LAB
LAB
WASH ROOM
253P
SPEC CHEMISTRY
253N
STORAGE
253R
EQUIP
253Q
BIOLOGY
253S
LAB OFFICE
253T MICROBIOLOGY
253U
HISTOLOGY
253V
TLT
254B
TLT
254A
LAB CONFERENCE
ROOM
ELEC.
COMMUNICATION
255A
SUPPLY STORE
253LHAC
253M
STORAGE
253K
BLOOD BANK
253J
ROOM
253K-A
KITCHEN
MINI AUDITORIUM
CHIEF VOL
SECRETARY
SOCIAL WORK
OFFICE
CATHOLIC CHAPLAIN
OFFICE
OFFICE
STOR
208 EMPLOYEE LOUNGE
SACRISTY
205A
HAC
CHAPLIN OFFICE
CHAPEL
216A
STAIR
S203
Project Title
DE
PA
RT
M
EN
T
OF
VE
TE
RA
NS
A
FF
AI
RS
Drawing Title Date
Project No.
Drawing No.
Dwg. Of
Approved: Associate Director for Operations:
Approved: Director, Medical Center:
Drawn:Building No: Checked:
Location:
Additions:
Revisions:
1 5 6 7 8
21 3 4 5 6 7 8
A B
C D
E o n e q u a r t e r i n c e f o o t o n e e i g h t h i n c e f o o t t h r e e e i g h t h s i n c e f o o t o n e h a l f i n c e f o o t o n e a n d o n e h a l f i n c e f o o t o n e i n c e f o o t t h r e e q u a r t e r s i n c e f o o t t h r e e i n c h e e f o o t
DELLC
JOB No.
JAMES E. VAN ZANDT
VETERANS ADMINISTRATION
MEDICAL CENTER
2 3 4
Consultants:Date
Bel Air, Maryland 21015-1457
2215 Conowingo Rd, Suite 100 fax 410.836.6611
410.803.0009
ARCHITECTURE
PLANNING
ENGINEERING
100% CONSTRUCTION DOCUMENTS
FULLY SPRINKLERED
BUILDING COST CONSULTANTS
COST ESTIMATING
12917 - 30TH AVENUE
PLATTSMOUTH, NEBRASKA 68048
402.298.8260 - FAX 402.298.8290
FIRE PROTECTION ENGINEERING
8815 CENTRE PARK DR., SUITE 200
COLUMBIA, MARYLAND 21045
410.750.2246 - FAX 410.750.2588
KOFFEL ASSOCIATES, INC.
BLDG 01 - 2ND FLOOR
REFLECTED CEILING PLANS-
PARTS A, B & C
MAKE FIRE SAFETY
IMPROVEMENTS
CDP/ CAJ WFPH/ DGW
06/26/2018
1-2-1
503-17-107
170703D
SCALE: 1/8" = 1'-0"
4'-0"8'-0"0 16'-0"
PLAN NORTH
TRUE NORTH
SCALE: 1/8" = 1'-0"1-2-1
1 2ND FLOOR REFLECTED CEILING PLAN - PART A
8 26
SCALE: 1/8" = 1'-0"1-2-1
2 2ND FLOOR REFLECTED CEILING PLAN - PART B
SCALE: 1/8" = 1'-0"1-2-1
3 2ND FLOOR REFLECTED CEILING PLAN - PART C
ALTOONA, PA
AutoCAD SHX Text A
AutoCAD SHX Text B
AutoCAD SHX Text C
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
FREIGHT ELEVATOR
AutoCAD SHX Text
AutoCAD SHX Text
AREAS NOT INCLUDED IN ARCHITECTURAL SCOPE OF WORK
AutoCAD SHX Text
2 HOUR FIRE BARRIER
AutoCAD SHX Text
FIRE & SMOKE BARRIER LEGEND
AutoCAD SHX Text
1 HOUR FIRE BARRIER
AutoCAD SHX Text
2 HOUR FIRE SMOKE BARRIER
AutoCAD SHX Text
30 MIN SMOKE BARRIER
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text 1 REMOVE EXISTING CEILING AS REQUIRED FOR FIRE PROTECTION WORK ABOVE CEILING. REMOVE EXISTING CEILING AS REQUIRED FOR FIRE PROTECTION WORK ABOVE CEILING. REINSTALL CEILING TO ORIGINAL CONDITION FOLLOWING NECESSARY WORK. ( SEE FIRE ENGINEERING DRAWING 1-2-FP1). 2 REMOVE EXISTING CEILING AS REQUIRED FOR FIRE PROTECTION WORK ABOVE CEILING. REMOVE EXISTING CEILING AS REQUIRED FOR FIRE PROTECTION WORK ABOVE CEILING. REINSTALL CEILING TO ORIGINAL CONDITION FOLLOWING NECESSARY WORK. ( SEE FIRE ENGINEERING DRAWING 1-2-FP2). 3 EXTERIOR SPRINKLERS TO BE INSTALLED THROUGH EXTERIOR WALL. SEE ARCHITECTURAL EXTERIOR SPRINKLERS TO BE INSTALLED THROUGH EXTERIOR WALL. SEE ARCHITECTURAL DETAILS SHEET A1 FOR WEATHER STOPPING, AND FIRE ENGINEERING DRAWING 1-2-FP2. 4 PATCH AND PAINT LATHE AND PLASTER TO MATCH EXISTING AS REQUIRED FOLLOWING PATCH AND PAINT LATHE AND PLASTER TO MATCH EXISTING AS REQUIRED FOLLOWING NECCESARY WORK. SEE FIRE ENGINEERING DRAWING 1-2-FP3. 5 REMOVE EXISTING CEILING AS REQUIRED FOR FIRE PROTECTION WORK ABOVE CEILING. REMOVE EXISTING CEILING AS REQUIRED FOR FIRE PROTECTION WORK ABOVE CEILING. REINSTALL CEILING TO ORIGINAL CONDITION FOLLOWING NECESSARY WORK. ( SEE FIRE ENGINEERING DRAWING 1-2-FP3.
AutoCAD SHX Text
NEW WORK ITEMS
AutoCAD SHX Text PHASING NOTES: ALL WORK PART A TO BE DAYLIGHT HOURS. ALL WORK PART B TO BE NIGHTS AND WEEKENDS. ALL WORK PART C TO BE DAYLIGHT HOURS.
GENERAL NOTE: PENETRATIONS SHALL BE PROPERLY FIRE SEALED WITH UL APPROVED FIRE SEAL. ANY PENETRATION WITH EXISTING NON-APPROVED FIRE SEAL, FIRE SEALANT, SHALL BE REMOVED AND REPLACED WITH NEW UL APPROVED FIRE SEALANT.
STAIR
S302
NURSING STATION
NURSING
EXAM ROOM
SOILED LINEN
EYE TECH
EYE
GU
HAC
MECHANICAL ROOM
WAITING ROOM
NEURO EXAM
CLOSET
EYE CLINIC
EYE TECH
NURSING
EXAM ROOM
EXAM ROOM
NURSING
TEL CLOSET
ELEC. CLOSET
TLT
STORAGE
LOBBY
386A
WAITING
316A
Room 322A
EYE EXAM
321A
STORAGE
319A
STAIR
S300
ELEVATOR
EQUIPMENT
332A
NURSING
333 CHECK OUT
335A
SECRETARY
335B
CORRIDOR
386B
CHIEF MED SERVICE
342C
OFFICE SURGERY
SERVICE
342B
TEL CLOSET
342D
STAIR
S302
SUPPLY CLOSET
316A
CORRIDOR
315A
WAREHOUSE SPD
STER ROOM SPD
HAC
GALV STEEL WALL SLEEVE
GALV STEEL BLADES WITH
INTERLOCKING JOINTS IN
GALV STEEL FRAME
REPLACEABLE FUSIBLE
LINK HOOK TO CINCH
DUCT
MIN 12"x12" DUCT
ACCESS PANEL
1 1/2"x1 1/2"x1/8" GALV STEEL
CONTINUOUS MOUNTING
ANGLE, BOLT TO WALL SLEEVE
WALL
FIRE STOP MATERIAL
WITH INCOMBUSTIBLE
US GYPSUM FIRE
PROOF MINERAL WOOL
"THERMOFIBER" SAFING
DUCT
STANDING "S" SLIP
(BREAKAWAY)
CONNECTION
NOTES: 1. FIRE DAMPERS TO HAVE BREAKAWAY JOINT BETWEEN COLLARS AND DUCT.
(COLLARS SHALL BE INTEGRAL WITH FIRE DAMPERS FRAME).
2. FIRE DAMPER SHALL BE U.L. LABELED.
3. GALVANIZED SLEEVE AND FRAME CONSTRUCTION SHALL BE MINIMUM 20
GA. SHOULD DUCT BE HEAVIER THAN 20 GAUGE, PROVIDE SLEEVE AND
FRAME TO MATCH DUCT CONSTRUCTION.
NO SCALE
HORIZONTAL DUCT FIRE DAMPER DETAIL
MDD073
1-3-1
MECHANICAL ROOM
WAITING ROOM
STAIR
S300
ELEVATOR
EQUIPMENT
332A
MECHANICAL ROOM
WAITING ROOM
STAIR
S300
ELEVATOR
EQUIPMENT
332A
Project Title
DE
PA
RT
M
EN
T
OF
VE
TE
RA
NS
A
FF
AI
RS
Drawing Title Date
Project No.
Drawing No.
Dwg. Of
Approved: Associate Director for Operations:
Approved: Director, Medical Center:
Drawn:Building No: Checked:
Location:
Additions:
Revisions:
1 5 6 7 8
21 3 4 5 6 7 8
A B
C D
E o n e q u a r t e r i n c e f o o t o n e e i g h t h i n c e f o o t t h r e e e i g h t h s i n c e f o o t o n e h a l f i n c e f o o t o n e a n d o n e h a l f i n c e f o o t o n e i n c e f o o t t h r e e q u a r t e r s i n c e f o o t t h r e e i n c h e e f o o t
DELLC
JOB No.
JAMES E. VAN ZANDT
VETERANS ADMINISTRATION
MEDICAL CENTER
2 3 4
Consultants:Date
Bel Air, Maryland 21015-1457
2215 Conowingo Rd, Suite 100 fax 410.836.6611
410.803.0009
ARCHITECTURE
PLANNING
ENGINEERING
100% CONSTRUCTION DOCUMENTS
FULLY SPRINKLERED
BUILDING COST CONSULTANTS
COST ESTIMATING
12917 - 30TH AVENUE
PLATTSMOUTH, NEBRASKA 68048
402.298.8260 - FAX 402.298.8290
FIRE PROTECTION ENGINEERING
8815 CENTRE PARK DR., SUITE 200
COLUMBIA, MARYLAND 21045
410.750.2246 - FAX 410.750.2588
KOFFEL ASSOCIATES, INC.
BLDG 01 - 3RD FLOOR
REFLECTED CEILING PLAN
- PART A & PART B
MAKE FIRE SAFETY
IMPROVEMENTS
CDP/ CAJ WFPH/ DGW
06/26/2018
1-3-1
503-17-107
170703D
SCALE: 1/8" = 1'-0"
4'-0"8'-0"0 16'-0"
PLAN NORTH
TRUE NORTH
SCALE: 1/8" = 1'-0"1-3-1
1 3RD FLOOR REFLECTED CEILING PLAN - PART A
9 26
SCALE: 1/8" = 1'-0"1-3-1
2 3RD FLOOR REFLECTED CEILING PLAN - PART B
SCALE: 1/4" = 1'-0"1-3-1
3 3RD FLOOR MECHANICAL ROOM NEW WORK PLAN
SCALE: 1/4" = 1'-0"1-3-1
4 3RD FLOOR MECHANICAL ROOM DEMO PLAN
1-3-1
5 3RD FLOOR MECHANICAL ROOM DEMO SECTION
1-3-1
6 3RD FLOOR MECHANICAL ROOM NEW WORK SECTION
ALTOONA, PA
AutoCAD SHX Text A
AutoCAD SHX Text B
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text A
AutoCAD SHX Text B
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AREAS NOT INCLUDED IN ARCHITECTURAL SCOPE OF WORK
AutoCAD SHX Text
2 HOUR FIRE BARRIER
AutoCAD SHX Text
FIRE & SMOKE BARRIER LEGEND
AutoCAD SHX Text
1 HOUR FIRE BARRIER
AutoCAD SHX Text
2 HOUR FIRE SMOKE BARRIER
AutoCAD SHX Text
30 MIN SMOKE BARRIER
AutoCAD SHX Text
AutoCAD SHX Text
EXISTING DAMPER
AutoCAD SHX Text
EXISTING EQUIPMENT
AutoCAD SHX Text
EXISTING PIPE
AutoCAD SHX Text
OUTSIDE EXHAUST
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
EXISTING DAMPER
AutoCAD SHX Text
EXISTING EQUIPMENT
AutoCAD SHX Text
EXISTING PIPE
AutoCAD SHX Text
OUTSIDE EXHAUST
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
DUCTWORK
AutoCAD SHX Text
REMOVE EXISTING BLOCK
AutoCAD SHX Text
ALL ELECTRIC & CONDUIT TO REMAIN
AutoCAD SHX Text
NEW DUCT AND DAMPER
AutoCAD SHX Text
NEW MASONRY
AutoCAD SHX Text
ALL ELECTRIC & CONDUIT TO REMAIN
AutoCAD SHX Text
AutoCAD SHX Text
14" MIN. STEEL LINTEL
AutoCAD SHX Text
4" MIN. EMBEDMENT DEPTH
AutoCAD SHX Text
AutoCAD SHX Text
A ELEVATOR EQUIPMENT ROOM
AutoCAD SHX Text
B LOBBY, ABOVE CEILING PENETRATION
AutoCAD SHX Text NEW WORK NOTES 1 ONE (1) 8" PENETRATION; 2 HOUR FIRE SEAL PIPE PENETRATION. ONE (1) 8" PENETRATION; 2 HOUR FIRE SEAL PIPE PENETRATION. 2 50" x 40" OPENING AROUND DUCT PENETRATION IN 2 HOUR FIRE RATED WALL. 50" x 40" OPENING AROUND DUCT PENETRATION IN 2 HOUR FIRE RATED WALL. INSTALL FIRE BLOCK TO SEAL PENETRATION. SEE DETAILS 3-7 ON SHEET 1-3-1. 3 REMOVE EXISTING CEILING TILE AS REQUIRED FOR ARCHITECTURAL WORK ABOVE CEILING. REMOVE EXISTING CEILING TILE AS REQUIRED FOR ARCHITECTURAL WORK ABOVE CEILING. ABOVE CEILING. REINSTALL CEILING TO ORIGINAL CONDITION FOLLOWING NECESSARY WORK. 4 INSTALL PUSH TO OPEN PADDLE TIED INTO ELECTRIC MAGNETIC LOCK INSTALL PUSH TO OPEN PADDLE TIED INTO ELECTRIC MAGNETIC LOCK TO RELEASE LOCK ON ACTIVATION. 5 INSTALL NEW SECTION OF DUCTWORK AND NEW DAMPER WITHIN WALL, SEE DETAIL 1. INSTALL NEW SECTION OF DUCTWORK AND NEW DAMPER WITHIN WALL, SEE DETAIL 1. 6 DIMENSIONS TO BE FIELD VERIFIED DIMENSIONS TO BE FIELD VERIFIED 7 2 HOUR FIRE SEAL ENTIRE PENETRATION 2 HOUR FIRE SEAL ENTIRE PENETRATION 8 DEMO BLOCK AND DUCTWORK AS NECESSARY DEMO BLOCK AND DUCTWORK AS NECESSARY 9 INSTALL ACCESS PANEL TO EXISTING DAMPER INSTALL ACCESS PANEL TO EXISTING DAMPER 10 SEE DETAILS 3, 4, 5, 6, AND 7 ON SHEET 1-3-1.SEE DETAILS 3, 4, 5, 6, AND 7 ON SHEET 1-3-1.
AutoCAD SHX Text
PHASING NOTES: ALL WORK THIS SHEET TO BE DONE DURING DAYLIGHT HOURS.
AutoCAD SHX Text
NOT TO SCALE
AutoCAD SHX Text
NOT TO SCALE
GENERAL NOTE: PENETRATIONS SHALL BE PROPERLY FIRE SEALED WITH UL APPROVED FIRE SEAL. ANY PENETRATION WITH EXISTING NON-APPROVED FIRE SEAL, FIRE SEALANT, SHALL BE REMOVED AND REPLACED WITH NEW UL APPROVED FIRE SEALANT.
OFFICE
CONFERENCE ROOM
TELCOM
ROOM
KITCHEN
VENDING
STORAGE
WOMENS TOILETS
STORAGE
MENS TOILETS
STORAGE
JOINT COMMISION
OFFICE
710A&B
UTILIZATION REVIEW
OFFICE
HOUSEKEEPING
MANAGER ACUTE &
EXTENDED CARE
DEPT
MAILROOM
ASSOCIATE
DIRECTOR
COMPLIANCE
OFFICER DIR. OFFICE
CHIEF OF STAFF
CONFERENCE ROOM
PUBLIC AFFAIRS
OFFICER
SEC NURSING
ASSOCIATE NURSING
ASSOCIATE
DIRECTOR
ASSOCIATE
DIRECTOR SEC
DIRECTOR SEC
DIRECTOR'S SUITE
ELEC
PROGRAM SUPPORT
CHIEF OF STAFF
CHIEF OF STAFF
SEC CHIEF OF STAFF
OFFICE
PROGRAM SUPPORT
ASSISTANT FOR
DIRECTOR
STORAGE
EXECUTIVE OFFICER
SUPPLIES
EQUIPMENT RM
OFFICE
STORAGE
A O NURSING
WOMEN'S VETERAN'S
PROGRAM MANGER
PATIENT SAFETY
MANAGER
PUBLIC AFFAIRS
SUPPORT
STAIR
S702
STAIR
S700
TOILET
7423A
STAIR
S701
TOILET
734A
E L
E V
A T
O R
S
Project Title
DE
PA
RT
M
EN
T
OF
VE
TE
RA
NS
A
FF
AI
RS
Drawing Title Date
Project No.
Drawing No.
Dwg. Of
Approved: Associate Director for Operations:
Approved: Director, Medical Center:
Drawn:Building No: Checked:
Location:
Additions:
Revisions:
1 5 6 7 8
21 3 4 5 6 7 8
A B
C D
E o n e q u a r t e r i n c e f o o t o n e e i g h t h i n c e f o o t t h r e e e i g h t h s i n c e f o o t o n e h a l f i n c e f o o t o n e a n d o n e h a l f i n c e f o o t o n e i n c e f o o t t h r e e q u a r t e r s i n c e f o o t t h r e e i n c h e e f o o t
DELLC
JOB No.
JAMES E. VAN ZANDT
VETERANS ADMINISTRATION
MEDICAL CENTER
2 3 4
Consultants:Date
Bel Air, Maryland 21015-1457
2215 Conowingo Rd, Suite 100 fax 410.836.6611
410.803.0009
ARCHITECTURE
PLANNING
ENGINEERING
100% CONSTRUCTION DOCUMENTS
FULLY SPRINKLERED
BUILDING COST CONSULTANTS
COST ESTIMATING
12917 - 30TH AVENUE
PLATTSMOUTH, NEBRASKA 68048
402.298.8260 - FAX 402.298.8290
FIRE PROTECTION ENGINEERING
8815 CENTRE PARK DR., SUITE 200
COLUMBIA, MARYLAND 21045
410.750.2246 - FAX 410.750.2588
KOFFEL ASSOCIATES, INC.
BLDG 01 - 7TH FLOOR
REFLECTED CEILING PLAN
MAKE FIRE SAFETY
IMPROVEMENTS
CDP/ CAJ WFPH/ DGW
06/26/2018
1-7-1
503-17-107
170703D
SCALE: 1/8" = 1'-0"
4'-0"8'-0"0 16'-0"
SCALE: 1/8" = 1'-0"1-7/8-1
1 7TH FLOOR REFLECTED CEILING PLAN
PLAN NORTH
TRUE NORTH
7TH FLOOR
10 26
ALTOONA, PA
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text B
AutoCAD SHX Text A
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AREAS NOT INCLUDED IN ARCHITECTURAL SCOPE OF WORK
AutoCAD SHX Text
2 HOUR FIRE BARRIER
AutoCAD SHX Text
FIRE & SMOKE BARRIER LEGEND
AutoCAD SHX Text
1 HOUR FIRE BARRIER
AutoCAD SHX Text
2 HOUR FIRE SMOKE BARRIER
AutoCAD SHX Text
30 MIN SMOKE BARRIER
AutoCAD SHX Text
A CORRIDOR SMOKE BARRIER PENETRATION
AutoCAD SHX Text
B CORRIDOR FIRE WALL PENETRATION
AutoCAD SHX Text NEW WORK NOTES 1 THREE (3) 4" FIRE BARRIER PENETRATIONS; SEAL PENETRATION WITH 2 HOUR THREE (3) 4" FIRE BARRIER PENETRATIONS; SEAL PENETRATION WITH 2 HOUR RATED FIRE SEAL. 2 ONE (1) 6" x 12" PENETRATION SEAL; SEAL PENETRATION WITH SMOKE TIGHT ONE (1) 6" x 12" PENETRATION SEAL; SEAL PENETRATION WITH SMOKE TIGHT SEALANT. 3 REMOVE EXISTING CEILING TILE AS REQUIRED FOR FIRE PROTECTION WORK ABOVE REMOVE EXISTING CEILING TILE AS REQUIRED FOR FIRE PROTECTION WORK ABOVE CEILING. REINSTALL TO FINAL CONDITION FOLLOWING NECESSARY WORK. (SEE FIRE ENGINEERING DRAWING 1-7-FP1) 4 REMOVE EXISTING CEILING TILE AS REQUIRED FOR ARCHITECTURAL WORK ABOVE REMOVE EXISTING CEILING TILE AS REQUIRED FOR ARCHITECTURAL WORK ABOVE CEILING. REINSTALL TO FINAL CONDITION FOLLOWING NECESSARY WORK.
AutoCAD SHX Text
PHASING NOTES: ALL WORK THIS SHEET TO BE DONE DURING DAYLIGHT HOURS.
GENERAL NOTE: PENETRATIONS SHALL BE PROPERLY FIRE SEALED WITH UL APPROVED FIRE SEAL. ANY PENETRATION WITH EXISTING NON-APPROVED FIRE SEAL, FIRE SEALANT, SHALL BE REMOVED AND REPLACED WITH NEW UL APPROVED FIRE SEALANT.
10'-8"
5"
1'-9
10'-5"
5'-6
9'-6
VAMC Altoona, Pennsylvania
06/26/2018
503-17-107
ARCHITECTURE
PLANNING
ENGINEERING
MAKE FIRE SAFETY
IMPROVEMENTS
BUILDING COST CONSULTANTS
COST ESTIMATING
12917 - 30TH AVENUE
PLATTSMOUTH, NEBRASKA 68048
402.298.8260 - FAX 402.298.8290
KOFFEL ASSOCIATES
FIRE PROTECTION ENGINEERS
8815 CENTRE PARK DRIVE, SUITE 200
COLUMBIA, MARYLAND 21045
410.750.2246 - FAX 410.750.2588
DELLC
JOB NO. 170703D
100% CONSTRUCTION DOCUMENTS
FULLY SPRINKLED
AutoCAD SHX Text
COVER PLATE
AutoCAD SHX Text
BACKER ROD & SEALANT - ALL AROUND
AutoCAD SHX Text
PIPE
AutoCAD SHX Text
EXTERIOR WALL
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text NEW WORK NOTES: DEMO EXISTING ROOF; STRUCTURE TO REMAIN. REPAINT STEEL TO MATCH EXISTING BEFORE NEW ROOF IS INSTALLED. REPLACE ROOF WITH PURLINS AND STANDING SEAM ROOF.
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
DRAWING NO.
AutoCAD SHX Text Dwg.
AutoCAD SHX Text Of
AutoCAD SHX Text Project No.
AutoCAD SHX Text Date
AutoCAD SHX Text Project Title
AutoCAD SHX Text Building Number
AutoCAD SHX Text Checked
AutoCAD SHX Text Drawn
AutoCAD SHX Text Location
AutoCAD SHX Text Drawing Title
AutoCAD SHX Text Approved: Division Chief
AutoCAD SHX Text Approved: Service Director
AutoCAD SHX Text Revisions
AutoCAD SHX Text Date
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text F
AutoCAD SHX Text E
AutoCAD SHX Text D
AutoCAD SHX Text C
AutoCAD SHX Text B
AutoCAD SHX Text A
AutoCAD SHX Text A
AutoCAD SHX Text B
AutoCAD SHX Text C
AutoCAD SHX Text D
AutoCAD SHX Text E
AutoCAD SHX Text F
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text one-eighth inch = one foot
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text one-quarter inch = one foot
AutoCAD SHX Text three-eighths inch = one foot
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text one-half inch = one foot
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text three-quarters inch = one foot
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text one inch = one foot
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text one and one-half inch = one foot
AutoCAD SHX Text three inches = one foot
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text James E. Van Zandt
AutoCAD SHX Text Medical Center
AutoCAD SHX Text Veterans Administration
AutoCAD SHX Text
AutoCAD SHX Text Consultants
AutoCAD SHX Text
AutoCAD SHX Text
%%U KEY PLAN
AutoCAD SHX Text 2215 Conowingo Rd, Suite 100 Bel Air, Maryland 21015-1436 410.803.0009 fax 410.836.6611
AutoCAD SHX Text
ARCHITECTURAL
AutoCAD SHX Text
DETAIL SHEET -
AutoCAD SHX Text
WPH
AutoCAD SHX Text A1
AutoCAD SHX Text
JSK
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text A1
AutoCAD SHX Text
WEATHER STOPPING DETAIL (TYP.)
AutoCAD SHX Text
SCALE: 1 1/2" = 1'-0"
AutoCAD SHX Text
AutoCAD SHX Text A1
AutoCAD SHX Text
SMOKE SHED - PLAN
AutoCAD SHX Text
SCALE: 1/2"=1'-0"
AutoCAD SHX Text
AutoCAD SHX Text A1
AutoCAD SHX Text
SMOKE SHED - ELEVATION
AutoCAD SHX Text
SCALE: 1/2"=1'-0"
AutoCAD SHX Text
DEMO EXISTING ROOF; STRUCTURE TO REMAIN
AutoCAD SHX Text
PHASING NOTES: ALL WORK THIS SHEET TO BE DONE DURING DAYLIGHT HOURS.
SMOKE SHED
Project Title
DE
PA
RT
M
EN
T
OF
VE
TE
RA
NS
A
FF
AI
RS
Drawing Title Date
Project No.
Drawing No.
Dwg. Of
Approved: Associate Director for Operations:
Approved: Director, Medical Center:
Drawn:Building No: Checked:
Location:
Additions:
Revisions:
1 5 6 7 8
21 3 4 5 6 7 8
A B
C D
E on e-qu ar te r i nc h on e fo ot on e-ei gh th in ch o ne fo ot th re e-ei gh th s in ch o ne fo ot on e-ha lf in ch o ne fo ot on e an d on e ha lf in ch o ne fo ot on e in ch o ne fo ot th re e-qu ar te rs in ch o ne fo ot th re e in ch es o ne fo ot
DELLC
JOB No.
JAMES E. VAN ZANDT
VETERANS ADMINISTRATION
MEDICAL CENTER
2 3 4
Consultants:
Date
Bel Air, Maryland 21015-1457 2215 Conowingo Rd, Suite 100 fax 410.836.6611 410.803.0009
ARCHITECTURE
PLANNING
ENGINEERING
100% CONSTRUCTION DOCUMENTS
FULLY SPRINKLERED
BUILDING COST CONSULTANTS
COST ESTIMATING
12917 - 30TH AVENUE
PLATTSMOUTH, NEBRASKA 68048
402.298.8260 - FAX 402.298.8290
FIRE PROTECTION ENGINEERING
8815 CENTRE PARK DR., SUITE 200
COLUMBIA, MARYLAND 21045
410.750.2246 - FAX 410.750.2588
KOFFEL ASSOCIATES, INC.
06/26/2018
503-17-107
170703D
ALTOONA, PA
FP1
FIRE SUPPRESSION NOTES,
SYMBOLS, AND
ABBREVIATIONS
MAKE FIRE SAFETY
IMPROVEMENTS
MJA CRS
503-17-107
POC POINT OF CONNECTION
QR QUICK RESPONSE (SPRINKLER)
R RELOCATED
STL STEEL
TYP TYPICAL
UNO UNLESS NOTED OTHERWISE
FHV FIRE HOSE VALVE
GYP GYPSUM WALL BOARD (SHEETROCK)
HT HIGH TEMPERATURE (SPRINKLER)
ITC INSPECTORS TEST CONNECTION
MAX MAXIMUM
MIN MINIMUM
MT METAL TILE
NIC NOT IN CONTRACT
NS NON-SPRINKLERED
NTS NOT TO SCALE
FIRE SUPPRESSION ABBREVIATIONS
ACT ACOUSTICAL CEILING TILE
AFF ABOVE FINISHED FLOOR
BFP BACKFLOW PREVENTER
COL COLUMN
CONC CONCRETE
DN DOWN
EC EXTENDED COVERAGE (SPRINKLER)
ETR EXISTING TO REMAIN
EXP EXPOSED (NO CEILING)
FDC FIRE DEPARTMENT CONNECTION
UPRIGHT SPRINKLER;
ON SPRIG
PENDENT SPRINKLER;
ON DROP NIPPLE
SPRINKLER GUARD;
SHOWN ON UPRIGHT SPRINKLER
HEIGHT INDICATOR
NON-SPRINKLERED AREA
FULLY SPRINKLERED AREA
PARTIALLY SPRINKLERED AREA
AREA NOT IN PROJECT SCOPE
AREA NOT IN CURRENT PHASE
SPRINKLER ZONE BOUNDARY
TEMPORARY SPRINKLER ZONE BOUNDARY
TEMPORARY 1-HOUR ICRA FIRE BARRIER
PRESSURE GAUGE
ALARM CHECK VALVE
DRY PIPE VALVE
FIRE HYDRANT
FIRE DEPARTMENT CONNECTION
UPRIGHT SPRINKLER
PENDENT SPRINKLER
WATER METER
DRY SIDE WALL SPRINKLER
FLUSHING CONNECTION OR CAP
FLUSHING CONNECTION OR CAP
CONTROL VALVE
CHECK VALVE
OS&Y GATE VALVE
BUTTERFLY VALVE
NON-INDICATING CONTROL VALVE
BACKFLOW PREVENTER;
DOUBLE CHECK TYPE
POST-INDICATING VALVE
ZONE CONTROL VALVE ASSEMBLY
WATER FLOW SWITCH
NEW SYSTEM PIPING
EXISTING PIPING TO REMAIN
EXISTING PIPING TO BE REMOVED
NEW POINT OF CONNECTION
PIPE HANGER
SYSTEM RISER
DRAIN RISER
HOSE VALVE
PIPE ELBOW DOWN
PIPE TEE DOWN
CHANGE IN PIPE SIZE
8'-0"
AS
AS
NS
ZCVA
1. MODIFY WET-PIPE SPRINKLER PROTECTION THROUGHOUT BUILDING 1 OF
THE JAMES E. VAN ZANDT VETERANS ADMINISTRATION MEDICAL CENTER
AS PART OF THE MAKE FIRE SAFETY IMPROVEMENTS PROJECT.
2. THIS WORK WILL BE PHASED. REFER TO THE ARCHITECTURAL PHASING
PLANS.
3. PROVIDE ALL NECESSARY MATERIALS AND LABOR TO DESIGN AND INSTALL
A COMPLETE AND OPERATIONAL SYSTEM AS DESCRIBED IN THE PROJECT
CONTRACT DOCUMENTS.
4. ALL REFERENCE TO THE AUTHORITY HAVING JURISDICTION (AHJ) SHALL
MEAN THE…
This is the start of the file's text. The full file is on GovTribe.