This is a Sources Sought Notice issued by the Department of Veterans Affairs for the Northport VA Medical Center. The notice seeks market research and interest from small business manufacturers or distributors for a specific medical equipment purchase: one (1) Medrad Mark 7 Arterion Injection System (Pedestal Mount, Item Number ART700 PEDL), to be used in the operating room. The solicitation is set aside for Service-Disabled Veteran-Owned Small Businesses (SDVOSB) under NAICS code 334510 for Electromedical and Electrotherapeutic Apparatus Manufacturing, with a response deadline of 07/22/2025 at 10:00 AM Eastern Time.
Specific requirements include purchasing a new power injector for the Northport VA Medical Center, with strict prohibitions on used or refurbished equipment. The delivery location is 79 Middleville Road, Northport, NY 11768. Interested small businesses are requested to email Sanchez Reid at Sanchez.Reid@va.gov with their firm's name, socio-economic category, complete contact information, and a letter of authorization for distribution. This sources sought notice is for market research purposes only and does not constitute a formal solicitation or government commitment to purchase.
View the file
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Sources Sought Notice Sources Sought Notice
| SUBJECT* |
| EQUIPMENT - POWER INJECTOR (VASCULAR) |
GENERAL INFORMATION
| CONTRACTING OFFICE’S ZIP CODE* |
| 10468-3904 |
| SOLICITATION NUMBER* |
| 36C24225Q0810 |
| RESPONSE DATE/TIME/ZONE |
| 07-22-2025 10:00AM EASTERN TIME, NEW YORK, USA |
| ARCHIVE |
| 15 DAYS AFTER THE RESPONSE DATE |
| RECOVERY ACT FUNDS |
| N |
| SET-ASIDE |
| SDVOSBC |
| PRODUCT SERVICE CODE* |
| 6515 |
| NAICS CODE* |
| 334510 |
| CONTRACTING OFFICE ADDRESS |
| Department of Veterans Affairs |
Network Contracting Office 2 James J. Peters VA Medical Center 130 West Kingsbridge Road Bronx NY 10468-3904
POINT OF CONTACT*
Contract Specialist Sanchez Reid Sanchez.Reid@va.gov
908.647.0180 x 214466
PLACE OF PERFORMANCE
| ADDRESS |
| Northport VA Medical Center |
79 Middleville Road
Northport NY
| POSTAL CODE |
| 11768 |
| COUNTRY |
| USA |
ADDITIONAL INFORMATION
| AGENCY’S URL |
| https://www.va.gov/ |
| URL DESCRIPTION |
| VHA |
| AGENCY CONTACT’S EMAIL ADDRESS |
| Sanchez.Reid@va.gov |
| EMAIL DESCRIPTION |
| Network Contracting Office |
DESCRIPTION
The Northport VAMC requires the brand name or equal purchase of one (1) Power Injector to be used in the operating room. Used or refurbished equipment is unacceptable. This will be delivered to their Operating Room Department Northport VA Medical Center (address below).
TITLE: 38-Sources Sought Notice
SOL: 36C24225Q0810
DUE: 07/22/2025
SET ASIDE: SDVOSB
NAICS: 334510 – Electromedical and Electrotherapeutic Apparatus Manufacturing.
AGENCY: Department of Veterans Affairs, VA Health Care System, Northport VAMC, 79 Middleville Road, Northport, NY 11768.
POC: Sanchez Reid Mail all responses only to: Sanchez.Reid@va.gov
DESCRIPTION: This Sources Sought Notice is for informational and planning purposes only and shall not be construed as a solicitation or as an obligation or commitment by the Government at this time. This notice is intended strictly for market research. The purpose of this Sources Sought notice is to determine interest and capability of potential qualifications of Small Businesses firms relative to the North American Industry Classification Code (NAICS) 334510. The Department of Veteran’s Affairs is seeking all small business manufacturer or distributors of small business manufacturers, of the following brand name requirement.
Requirement: The Northport VAMC requires the brand name or equal purchase of one (1) Power Injector to be used in the operating room. Used or refurbished equipment is unacceptable. This will be delivered to their Operating Room Department Northport VA Medical Center (address below).
Looking for domestic end products only.
Specifications: This is a brand name or equal to Medrad Mark 7 Arterion portable power injector requirement.
| Item Number |
| Description |
| Quantity |
| ART700 PEDL |
| Medrad Mark 7 Arterion Injection System- Pedestal Mount |
| 1 |
Delivery Location:
Northport VA Medical Center 79 Middleville Road Northport, NY 11768
THIS IS NOT A SOLICITATION AND DOES NOT OBLIGATE THE GOVERNMENT TO ISSUE A SOLICITATION. Please be advised that the Government will not pay for any information submitted under this announcement. The applicable North American Classification System (NAICS) Code for this requirement is 334510 Small Electromedical and Electrotherapeutic Apparatus Manufacturing. Email should contain the following information: Name of firm, Socio-Economic category of the firm, complete address, phone & fax number of contacts, letter of authorization for distribution.
| *= Required Field |
| Sources Sought Notice |
Sources Sought Notice
File details come from the government source that posted it. Updated .