36C24223Q0421_2.docx
DOCX document 19 KB Posted
- Attached to
- 6115--PORTABLE 500KW DIESEL GENERATOR Federal contract opportunity
- Solicitation number
- 36C24223Q0421
About this file
This document is a combined synopsis/solicitation notice from the Department of Veterans Affairs seeking a portable 500kW diesel generator. The solicitation is a 100% set-aside for Service-Disabled Veteran-Owned Small Businesses. Responses are due by May 3, 2023 at 3:00PM Eastern Time and must include company information, capability statements, and be submitted using the attached Request for Quotation. The generator specifications include a 500KW diesel fueled generator set in a sound attenuated containerized module mounted on a trailer with dimensions no larger than 8 feet 6 inches wide and 10 feet 3 inches tall. The generator must meet EPA Tier 4 emission standards and have equipment for remote monitoring and control. Offerors must be registered in the System for Award Management and Veterans Affairs VetBiz Vendor Information Pages.
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| 36C24223Q0421_1.R1.pdf | ||
| 36C24223Q0421_3.docx | DOCX document | |
| 36C24223Q0421_1.pdf |
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Combined Synopsis/Solicitation Notice Combined Synopsis/Solicitation Notice
| SUBJECT* |
| PORTABLE 500KW DIESEL GENERATOR |
GENERAL INFORMATION
| CONTRACTING OFFICE’S ZIP CODE* |
| 10468-3904 |
| SOLICITATION NUMBER* |
| 36C24223Q0421 |
| RESPONSE DATE/TIME/ZONE |
| 05-03-2023 15:00 EASTERN TIME, NEW YORK, USA |
| ARCHIVE |
| 90 DAYS AFTER THE RESPONSE DATE |
| RECOVERY ACT FUNDS |
| N |
| SET-ASIDE |
| SDVOSBC |
| PRODUCT SERVICE CODE* |
| 6115 |
| NAICS CODE* |
| 335312 |
| CONTRACTING OFFICE ADDRESS |
| Department of Veterans Affairs |
Network Contracting Office 2 James J. Peters VA Medical Center 130 West Kingsbridge Road Bronx NY 10468-3904
POINT OF CONTACT*
Contracting Officer Paul Speedling Paul.Speedling@va.gov
(914) 737-4400 x202107
PLACE OF PERFORMANCE
| ADDRESS |
| Engineering Services |
Montrose VA Medical Center
VA Hudson Valley Healthcare System
2094 Albany Post Rd
Montrose NY
| POSTAL CODE |
| 10548 |
| COUNTRY |
| USA |
ADDITIONAL INFORMATION
AGENCY’S URL
URL DESCRIPTION
AGENCY CONTACT’S EMAIL ADDRESS
EMAIL DESCRIPTION
DESCRIPTION
This is a COMBINED SYNOPSIS/SOLICITATION NOTICE for
Portable 500 kW Diesel Generator
Responses to this Combined Synopsis/Solicitation must be in writing and submitted on the attached Request for Quotation (Form SF1449).
100% SDVOSB set-aside.
NAICS Code: 335312; size standard: 1,250 employees; PSC: 6115
Responses to this notice shall include the following: (a) company name b) address (c) point of contact (d) phone, fax, and email (e) SAM UEI (f) Cage Code (g) Tax ID Number (h) and must provide a capability statement that addresses the organizations qualifications and ability to perform as a contractor and provide the commodities described within the Request For Quotation.
VA Hudson Valley Healthcare System at Montrose VA Medical Center, Engineering Service, is seeking to purchase a Portable 500kW Diesel Generator.
Portable 500 kW Diesel Generator
Objective:
This generator will meet, at a minimum, the following physical and performance characteristics:
· One (1) new diesel fueled Standby Generator set rated at 500 KW, variable voltage, (208/240/480), 60 HZ, 3 phase, 0.8 power factor at 1800 rpm.
· Cam lock and busbar distribution panel
· Generator has a minimum of (2) 120 V GFCIs and (3) 50 amp 240 volt
· Generator set in containerized module with sound attenuated air intake louvers and insulated interior walls and ceilings with minimum 4” of acoustic paneling.
· Trailer has two-axle, air-ride chassis with anti-lock brake system and shall have an overall width of no more than 8’- 6” and an overall height with the mounted generator set not to exceed 10’-3” It shall be towable using a standard ball hitch.
· Sound attenuated container with minimum 76dB(A) at 25 feet per SAE J1074 measured at 75% prime load.
· 110% spill containment of onboard engine fluids and variable speed cooling fan for reduced fuel consumption and reduced sound at partial loads.
· Shore power connection via distribution block connections for jacket water heater, battery charger, space heaters, generator condensate heaters and internal duplex service receptacle.
· Generator set mounted controller with automatic start/stop with cooldown timer and manual and automatic paralleling capability. Genset equipped with hardware to provide two-way communication for remote control and equipment monitoring via cellular network.
· Fuel/Emissions strategy to meet US EPA Tier 4 Final emission standards and CARB certified for non-road mobile application.
· Engine to have double-wall fuel tank, UL 142 listed with leak detection sensor and complies with capacity of 24-hour runtime @ 75% prime, internal and external fuel fill.
· Engine equipped with 25-gal plastic Diesel Exhaust Fluid (DEF) tank with integrated pump, level sensor to display the DEF level in control panel and electrically heated lines from DEF tank to CEM.
· Clean Emissions Modules (CEM) comes with integrated CRS, DOC, DPF, and SCR and is located in separate compartment.
· UL listed 208/240V, 20 amp battery charger, shock-mounted and enclosed in dust-proof housing. Lube system consists of pump, integral oil cooler, lube oil, filter, filler and dipstick, and oil sampling valve.
· Cooling system with vertically mounted radiator with vertical air discharge from the container to provide 47o C ambient capability at prime rating and 500m.
· Suppler shall deliver, set up and demonstrate full acceptable operational performance prior to acceptance by COR/POC. This shall include documented on-site load bank test and shall include demonstration of the emergency stop capability.
· Supplier shall provide (2) O & M manuals and a minimum of 1 hr of training to campus electrical staff and mechanics.
All offers must be submitted using the attached RFQ along with any other relevant information as per FAR 52.212-2 Evaluation – Section E - page 40.
The Government is not obligated to nor will it pay for or reimburse any costs associated with responding to this Combined Synopsis/Solicitation. This notice shall not be construed as a commitment by the Government to award a contract, nor does it restrict the Government to a particular acquisition approach.
Notice to Potential Offerors: All Offerors who provide goods or services to the United States Federal Government must be registered in the System for Award Management (SAM located on the web at www.sam.gov). It is desirable that any Offeror to have completed their business Online Representations and Certifications Application (ORCA). Additionally, all Service Disabled Veteran Owned Small Businesses who respond to a solicitation on this project must be registered with the Department of Veterans Affairs Center for Veterans Enterprise VetBiz Registry located at http://vip.vetbiz.gov. Requests for information and resultant responses shall be submitted directly to the contracting officer, Paul Speedling at Paul.Speedling@va.gov. NO TELEPHONE CALLS WILL BE ACCEPTED.
All submissions should be received no later than 15:00 EST on May 3, 2023.
See attached document: 36C24223Q0421_1.