AutoCAD SHX Text
DISCONNECT AND REMOVE EXISTING WATER COOLED UNIT AND REPLACE WITH NEW.
AutoCAD SHX Text -CONNECT NEW UNIT TO EXISTING DOMESTIC WATER WITH NEW SHUTOFF VALVE. -PROVIDE INDIRECT DRAIN FROM UNIT TO ABOVE EXISTING FLOOR DRAIN. -CONNECT TO EXISTING SUPPLY DUCTS ABOVE UNIT AND PROVIDE ALL NECESSARY TRANSITION PIECES. -PROVIDE POWER TO UNIT.
AutoCAD SHX Text
UNIT #10
AutoCAD SHX Text
MECH. RM.
AutoCAD SHX Text A32
AutoCAD SHX Text
208V DISCONNECT SWITCH
AutoCAD SHX Text REMOVE EXISTING EXHAUST FAN AND DUCTWORK AND REINSTALL AFTER INSTALLATION OF UNIT #10
AutoCAD SHX Text
DISCONNECT AND REMOVE EXISTING WATER COOLED UNIT AND REPLACE WITH NEW.
AutoCAD SHX Text -CONNECT NEW UNIT TO EXISTING DOMESTIC WATER WITH NEW SHUTOFF VALVE. -PROVIDE INDIRECT DRAIN FROM UNIT TO ABOVE EXISTING FLOOR DRAIN. -CONNECT TO EXISTING SUPPLY DUCTS ABOVE UNIT AND PROVIDE ALL NECESSARY TRANSITION PIECES. -PROVIDE POWER TO UNIT.
AutoCAD SHX Text
UNIT #9
AutoCAD SHX Text
RED ROOM
AutoCAD SHX Text A13
AutoCAD SHX Text
208V DISCONNECT SWITCH
AutoCAD SHX Text
DISCONNECT AND REMOVE EXISTING WATER COOLED UNIT AND REPLACE WITH NEW.
AutoCAD SHX Text -CONNECT NEW UNIT TO EXISTING DOMESTIC WATER WITH NEW SHUTOFF VALVE. -PROVIDE INDIRECT DRAIN FROM UNIT TO ABOVE EXISTING FLOOR DRAIN. -PROVIDE POWER TO UNIT.
AutoCAD SHX Text
UNIT #12
AutoCAD SHX Text
MICROBIOLOGY
AutoCAD SHX Text 234E
AutoCAD SHX Text
208V DISCONNECT SWITCH
AutoCAD SHX Text
%%UGENERAL NOTES
AutoCAD SHX Text PROVIDE SERVICE VALVES, PRESSURE VALVE, THERMOMETER AND PRESSURE GAUGE ON WATER SUPPLIES TO EACH UNIT.
AutoCAD SHX Text A.
AutoCAD SHX Text
DISCONNECT AND REMOVE EXISTING WATER COOLED UNIT AND REPLACE WITH NEW.
AutoCAD SHX Text -CONNECT NEW UNIT TO EXISTING DOMESTIC WATER WITH NEW SHUTOFF VALVE. -PROVIDE INDIRECT DRAIN FROM UNIT TO ABOVE EXISTING FLOOR DRAIN. -PROVIDE POWER TO UNIT.
AutoCAD SHX Text
UNIT #14
AutoCAD SHX Text
CORRIDOR
AutoCAD SHX Text 5D
AutoCAD SHX Text
208V DISCONNECT SWITCH
AutoCAD SHX Text
DISCONNECT AND REMOVE EXISTING WATER COOLED UNIT AND REPLACE WITH NEW.
AutoCAD SHX Text -CONNECT NEW UNIT TO EXISTING DOMESTIC WATER WITH NEW SHUTOFF VALVE. -PROVIDE INDIRECT DRAIN FROM UNIT TO ABOVE EXISTING FLOOR DRAIN. -CONNECT TO EXISTING SUPPLY DUCTS ABOVE UNIT AND PROVIDE ALL NECESSARY TRANSITION PIECES. -PROVIDE POWER TO UNIT.
AutoCAD SHX Text
UNIT #15
AutoCAD SHX Text
CONFERENCE ROOM
AutoCAD SHX Text
AutoCAD SHX Text
MECH. RM.
AutoCAD SHX Text 501C
AutoCAD SHX Text
208V DISCONNECT SWITCH
AutoCAD SHX Text
DISCONNECT AND REMOVE EXISTING WATER COOLED UNIT AND REPLACE WITH NEW.
AutoCAD SHX Text -CONNECT NEW UNIT TO EXISTING DOMESTIC WATER WITH NEW SHUTOFF VALVE. -PROVIDE INDIRECT DRAIN FROM UNIT TO ABOVE EXISTING FLOOR DRAIN. -CONNECT TO EXISTING SUPPLY DUCTS ABOVE UNIT AND PROVIDE ALL NECESSARY TRANSITION PIECES. -PROVIDE POWER TO UNIT.
AutoCAD SHX Text
UNIT #13
AutoCAD SHX Text
MECH. RM
AutoCAD SHX Text 334A
AutoCAD SHX Text
FREEDOM HALL
AutoCAD SHX Text 301A
AutoCAD SHX Text
208V DISCONNECT SWITCH
AutoCAD SHX Text
DISCONNECT AND REMOVE EXISTING WATER COOLED UNIT AND REPLACE WITH NEW.
AutoCAD SHX Text -CONNECT NEW UNIT TO EXISTING DOMESTIC WATER WITH NEW SHUTOFF VALVE. -PROVIDE INDIRECT DRAIN FROM UNIT TO ABOVE EXISTING FLOOR DRAIN. -PROVIDE POWER TO UNIT.
AutoCAD SHX Text
UNIT #16
AutoCAD SHX Text
CORRIDOR
AutoCAD SHX Text 6D
AutoCAD SHX Text
208V DISCONNECT SWITCH
AutoCAD SHX Text
DISCONNECT AND REMOVE EXISTING WATER COOLED UNIT AND REPLACE WITH NEW.
AutoCAD SHX Text -CONNECT NEW UNIT TO EXISTING DOMESTIC WATER WITH NEW SHUTOFF VALVE. -PROVIDE INDIRECT DRAIN FROM UNIT TO ABOVE EXISTING FLOOR DRAIN. -CONNECT TO EXISTING SUPPLY DUCTS ABOVE UNIT AND PROVIDE ALL NECESSARY TRANSITION PIECES. -PROVIDE POWER TO UNIT.
AutoCAD SHX Text
UNIT #11
AutoCAD SHX Text
DESK 5&6
AutoCAD SHX Text 117C
AutoCAD SHX Text
POLICE
AutoCAD SHX Text 116C
AutoCAD SHX Text INSULATE SUPPLY DUCT ABOVE CEILING WITH 1-1/2" 3/4 POUND WRAP. INSULATE ALL DUCTWORK SHOWN INCLUDING END RUNS.
AutoCAD SHX Text
INSULATE EXPOSED SUPPLY DUCT WITH 3 POUND 2" ASJ BOARD.
AutoCAD SHX Text 30"x10"
AutoCAD SHX Text 24"x10"
AutoCAD SHX Text 10"
AutoCAD SHX Text 10"
AutoCAD SHX Text 10"
AutoCAD SHX Text 8"
AutoCAD SHX Text 10"
AutoCAD SHX Text 10"
AutoCAD SHX Text 10"
AutoCAD SHX Text 16"x10"
AutoCAD SHX Text
208V DISCONNECT SWITCH
AutoCAD SHX Text
%%URED ROOM - UNIT #9
AutoCAD SHX Text
SCALE: 1/4"=1'-0"
AutoCAD SHX Text
VA WESTERN NEW YORK HEALTHCARE SYSTEM
AutoCAD SHX Text
BUFFALO, NEW YORK 14215
AutoCAD SHX Text
3495 BAILEY AVENUE
AutoCAD SHX Text three-quarters inch = one foot
AutoCAD SHX Text one-quarter inch = one foot
AutoCAD SHX Text one-eighth inch = one foot
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text Revisions
AutoCAD SHX Text Date
AutoCAD SHX Text three-eighths inch = one foot
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text one-half inch = one foot
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text one inch = one foot
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text Drawing Title
AutoCAD SHX Text Location
AutoCAD SHX Text
V.A.M.C. BUFFALO, NEW YORK
AutoCAD SHX Text Building Number
AutoCAD SHX Text Project Title
AutoCAD SHX Text Checked
AutoCAD SHX Text Drawn
AutoCAD SHX Text Office of Facilities
AutoCAD SHX Text Station No.
AutoCAD SHX Text Date
AutoCAD SHX Text E
AutoCAD SHX Text D
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text C
AutoCAD SHX Text B
AutoCAD SHX Text A
AutoCAD SHX Text
AC UNIT REPLACEMENTS
AutoCAD SHX Text
AutoCAD SHX Text
OCTOBER 16, 2018
AutoCAD SHX Text
AutoCAD SHX Text
SAFETY OFFICER
AutoCAD SHX Text
ENGINEERING MANAGER
AutoCAD SHX Text
CLINICAL ENGINEERING
AutoCAD SHX Text
MEDICAL CENTER DIRECTOR
AutoCAD SHX Text
DATE
AutoCAD SHX Text
DATE
AutoCAD SHX Text
CHIEF OF STAFF
AutoCAD SHX Text
DATE
AutoCAD SHX Text
DATE
AutoCAD SHX Text
CARELINE MANAGER
AutoCAD SHX Text
DATE
AutoCAD SHX Text
DATE
AutoCAD SHX Text
DATE
AutoCAD SHX Text
DATE
AutoCAD SHX Text
ASSOCIATE MEDICAL CENTER DIRECTOR
AutoCAD SHX Text
INFECTION CONTROL
AutoCAD SHX Text
RLR
AutoCAD SHX Text
PARTIAL FLOOR PLANS
AutoCAD SHX Text
RLR
AutoCAD SHX Text
MEDICAL CENTER DIRECTOR
AutoCAD SHX Text
DATE
AutoCAD SHX Text
DATE
AutoCAD SHX Text
ASSOCIATE MEDICAL CENTER DIRECTOR
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text E
AutoCAD SHX Text D
AutoCAD SHX Text C
AutoCAD SHX Text B
AutoCAD SHX Text A
AutoCAD SHX Text M102
AutoCAD SHX Text 18-S61-
AutoCAD SHX Text
%%UMICROBIOLOGY - UNIT #12
AutoCAD SHX Text
SCALE: 1/4"=1'-0"
AutoCAD SHX Text
%%UCANTEEN - UNIT #10
AutoCAD SHX Text
SCALE: 1/4"=1'-0"
AutoCAD SHX Text
SCALE: 1/4"=1'-0"
AutoCAD SHX Text
%%UCORIDOR 5D - UNIT #14
AutoCAD SHX Text
SCALE: 1/4"=1'-0"
AutoCAD SHX Text
%%UFREEDOM HALL - UNIT #13
AutoCAD SHX Text
SCALE: 1/4"=1'-0"
AutoCAD SHX Text
%%UCONFERENCE RM - UNIT #15
AutoCAD SHX Text
SCALE: 1/4"=1'-0"
AutoCAD SHX Text
%%UCORRIDOR 6D - UNIT #16
AutoCAD SHX Text
SCALE: 1/4"=1'-0"
AutoCAD SHX Text
%%UPOLICE OFFICE- UNIT #11
AutoCAD SHX Text
SCALE: 1/4"=1'-0"
AutoCAD SHX Text
SCALE: 1/4"=1'-0"