36C24218B0183-00001002.pdf
PDF 72 KB Posted
- Attached to
- 528A7-17-702 UPGRADE CHILLER PLANT SWITCHGEAR Federal contract opportunity
- Solicitation number
- 36C24218B0183
About this file
36C24218B0183 00001 087100_-_Door_Hardware REV.pdf
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| 36C24218C0085-000.docx | DOCX document | |
| 36C24218B0183-00001001.pdf | ||
| 36C24218B0183-00001000.docx | DOCX document | |
| 36C24218B0183-001.docx | DOCX document | |
| 36C24218B0183-002.pdf | ||
| 36C24218B0183-003.pdf | ||
| 36C24218B0183-004.docx | DOCX document | |
| 36C24218B0183-000.docx | DOCX document |
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
VA Project No. 528-A7-17-702 Syracuse VA Medical C enter AE Works Project No. 17007 Upgrade Chiller Plant S witchgear
Bid Set
01-01-16
08 71 00-1
SECTION 08 71 00
DOOR HARDWARE
PART 1 - GENERAL
1.1 DESCRIPTION
A. Door hardware and related items necessary for co mplete installation and operation of doors.
1.2 RELATED WORK
A. Caulking: Section 07 92 00 JOINT SEALANTS.
B. Application of Hardware: Section 08 11 13, HOLLO W METAL DOORS AND
FRAMES
C. Painting: Section 09 91 00, PAINTING.
D. Card Readers: Section 28 13 11, PHYSICAL ACCESS CONTROL SYSTEMS.
E. Electrical: Division 26, ELECTRICAL.
1.3 GENERAL
A. All hardware shall comply with UFAS, (Uniform Fe deral Accessible
Standards) unless specified otherwise.
B. Provide rated door hardware assemblies where req uired by most current version of the International Building Code (IBC).
C. Hardware for Labeled Fire Doors and Exit Doors: Conform to requirements of NFPA 80 for labeled fire doors and to NFPA 101 f or exit doors, as well as to other requirements specified. Provide ha rdware listed by UL, except where heavier materials, large size, or bett er grades are specified herein under paragraph HARDWARE SETS. In lieu of UL labeling and listing, test reports from a nationally recogni zed testing agency may be submitted showing that hardware has been tes ted in accordance with UL test methods and that it conforms to NFPA r equirements.
D. Hardware for application on metal and wood doors and frames shall be made to standard templates. Furnish templates to th e fabricator of these items in sufficient time so as not to delay t he construction.
E. The following items shall be of the same manufac turer, except as otherwise specified:
1. Mortise locksets.
2. Hinges for hollow metal and wood doors.
3. Surface applied overhead door closers.
4. Exit devices.
08 71 00-2
1.4 WARRANTY
A. Warranty period shall be two years for all items except as noted below:
1. Locks, latchsets, and panic hardware: 5 years.
2. Door closers and continuous hinges: 10 years.
1.5 MAINTENANCE MANUALS
A. In accordance with Section 01 00 00, GENERAL REQ UIREMENTS Article titled "INSTRUCTIONS", furnish maintenance manuals and instructions on all door hardware. Provide installation instruction s with the submittal documentation.
1.6 SUBMITTALS
A. Submittals shall be in accordance with Section 0 1 33 23, SHOP DRAWINGS, PRODUCT DATA AND SAMPLES. Submit 6 copies of the sc hedule per Section
01 33 23. Submit 2 final copies of the final approv ed schedules to VAMC
Locksmith as record copies (VISN Locksmith if the V AMC does not have a locksmith).
B. Hardware Schedule: Prepare and submit hardware s chedule in the following form:
Hardware Item
Quantity Size Reference Publication Type No.
Finish Mfr.
Name and Catalog No.
Key Control Symbols
UL Mark (if fire rated and listed)
ANSI/BHMA
Finish Designation
C. Samples and Manufacturers' Literature:
1. Samples: All hardware items (proposed for the pr oject) that have not been previously approved by Builders Hardware Manuf acturers
Association shall be submitted for approval. Tag an d mark all items with manufacturer's name, catalog number and projec t number.
2. Samples are not required for hardware listed in the specifications by manufacturer's catalog number, if the contractor proposes to use the manufacturer's product specified.
D. Certificate of Compliance and Test Reports: Subm it certificates that hardware conforms to the requirements specified her ein. Certificates shall be accompanied by copies of reports as refere nced. The testing
08 71 00-3 shall have been conducted either in the manufacture r's plant and certified by an independent testing laboratory or c onducted in an independent laboratory, within four years of submit tal of reports for approval.
1.7 DELIVERY AND MARKING
A. Deliver items of hardware to job site in their o riginal containers, complete with necessary appurtenances including scr ews, keys, and instructions. Tag one of each different item of har dware and deliver to
Resident Engineer for reference purposes. Tag shall identify items by
Project Specification number and manufacturer's cat alog number. These items shall remain on file in Resident Engineer's o ffice until all other similar items have been installed in project, at which time the
Resident Engineer will deliver items on file to Con tractor for installation in predetermined locations on the proj ect.
1.8 PREINSTALLATION MEETING
A. Convene a preinstallation meeting not less than 30 days before start of installation of door hardware. Require attendance of parties directly affecting work of this section, including Contracto r and Installer, Project Engineer and VA Locksmith. Review the foll owing:
1. Inspection of door hardware.
2. Job and surface readiness.
3. Coordination with other work.
4. Protection of hardware surfaces.
5. Substrate surface protection.
6. Installation.
7. Adjusting.
8. Repair.
9. Field quality control.
10. Cleaning.
1.9 INSTRUCTIONS
A. Hardware Set Symbols on Drawings: Except for pro tective plates, door stops, mutes, thresholds and the like specified her ein, hardware requirements for each door are indicated on drawing s by symbols.
Symbols for hardware sets consist of letters (e.g., "HW") followed by a number. Each number designates a set of hardware it ems applicable to a door type.
08 71 00-4
B. Keying: All cylinders shall be keyed into existi ng system. Provide removable core cylinders that are removable only wi th a special key or tool without disassembly of knob or lockset. Keying information shall be furnished at a later date by theCOR.
C.
1.10 APPLICABLE PUBLICATIONS
A. The publications listed below form a part of thi s specification to the extent referenced. The publications are referenced in the text by the basic designation only. In text, hardware items are referred to by series, types, etc., listed in such specifications and standards, except as otherwise specified.
B. American Society for Testing and Materials (ASTM ):
F883-04.................Padlocks
E2180-07................Standard Test Method for De termining the
Activity of Incorporated Antimicrobial Agent(s)
In Polymeric or Hydrophobic Materials
C. American National Standards Institute/Builders H ardware Manufacturers
Association (ANSI/BHMA):
A156.1-06...............Butts and Hinges
A156.2-03...............Bored and Pre-assembled Loc ks and Latches
A156.3-08...............Exit Devices, Coordinators, and Auto Flush
Bolts
A156.4-08...............Door Controls (Closers)
A156.5-14...............Cylinders and Input Devices for Locks.
A156.6-05...............Architectural Door Trim
A156.8-05...............Door Controls-Overhead Stop s and Holders
A156.11-14..............Cabinet Locks
A156.12-05 .............Interconnected Locks and La tches
A156.13-05..............Mortise Locks and Latches S eries 1000
A156.14-07 .............Sliding and Folding Door Ha rdware
A156.15-06..............Release Devices-Closer Hold er, Electromagnetic and Electromechanical
A156.16-08..............Auxiliary Hardware
A156.17-04 .............Self-Closing Hinges and Piv ots
08 71 00-5
A156.18-06..............Materials and Finishes
A156.20-06 .............Strap and Tee Hinges, and H asps
A156.21-09..............Thresholds
A156.22-05..............Door Gasketing and Edge Sea l Systems
A156.23-04..............Electromagnetic Locks
A156.24-03..............Delayed Egress Locking Syst ems
A156.25-07 .............Electrified Locking Devices
A156.26-06..............Continuous Hinges
A156.28-07 .............Master Keying Systems
A156.29-07 .............Exit Locks and Alarms
A156.30-03 .............High Security Cylinders
A156.31-07 .............Electric Strikes and Frame Mounted Actuators
A156.36-10..............Auxiliary Locks
A250.8-03...............Standard Steel Doors and Fr ames
D. National Fire Protection Association (NFPA):
80-10...................Fire Doors and Other Openin g Protectives
101-09..................Life Safety Code
E. Underwriters Laboratories, Inc. (UL):
Building Materials Directory (2008)
PART 2 - PRODUCTS
2.1 BUTT HINGES
A. ANSI A156.1. Provide only three-knuckle hinges, except five-knuckle where the required hinge type is not available in a three-knuckle version (e.g., some types of swing-clear hinges). T he following types of butt hinges shall be used for the types of doors listed, except where otherwise specified:
1. Exterior Doors: Type A2112/A5112 for doors 900 m m (3 feet) wide or less and Type A2111/A5111 for doors over 900 mm (3 feet) wide.
Hinges for exterior outswing doors shall have non-r emovable pins.
Hinges for exterior fire-rated doors shall be of st ainless steel material.
2. Interior Doors: Type A8112/A5112 for doors 900 m m (3 feet) wide or less and Type A8111/A5111 for doors over 900 mm (3 feet) wide.
Hinges for doors exposed to high humidity areas (sh ower rooms, toilet rooms, kitchens, janitor rooms, etc. shall b e of stainless steel material.
08 71 00-6
B. Provide quantity and size of hinges per door lea f as follows:
1. Doors up to 1210 mm (4 feet) high: 2 hinges.
2. Doors 1210 mm (4 feet) to 2260 mm (7 feet 5 inches) high: 3 hinges minimum.
3. Doors greater than 2260 mm (7 feet 5 inches) high: 4 hinges.
4. Doors up to 900 mm (3 feet) wide, standard weight: 114 mm x 114 mm
(4-1/2 inches x 4-1/2 inches) hinges.
5. Doors over 900 mm (3 feet) to 1065 mm (3 feet 6 inc hes) wide, standard weight: 127 mm x 114 mm (5 inches x 4-1/2 inches).
6. Doors over 1065 mm (3 feet 6 inches) to 1210 mm (4 feet), heavy weight: 127 mm x 114 mm (5 inches x 4-1/2 inches).
7. Provide heavy-weight hinges where specified.
8. At doors weighing 330 kg (150 lbs.) or more, furnis h 127 mm (5 inch) high hinges.
2.2 CONTINUOUS HINGES
A. ANSI/BHMA A156.26, Grade 1-600.
1. Listed under Category N in BHMA's "Certified Pro duct Directory."
B. General: Minimum 0.120-inch- (3.0-mm-) thick, h inge leaves with minimum overall width of 4 inches (102 mm); fabrica ted to full height of door and frame and to template screw locations; with components finished after milling and drilling are complete
C. Continuous, Barrel-Type Hinges: Hinge with knuc kles formed around a
Teflon-coated 6.35mm (0.25-inch) minimum diameter p in that extends entire length of hinge.
1. Base Metal for Exterior Hinges: Stainless steel.
2. Base Metal for Interior Hinges: Stainless steel.
3. Base Metal for Hinges for Fire-Rated Assemblies: Stainless steel.
4. Provide with non-removable pin (hospital tip opt ion) at lockable outswing doors.
5. Where required to clear adjacent casing, trim, a nd wall conditions and allow full door swing, provide wide throw hinge s of minimum width required.
6. Provide with manufacturer’s cut-outs for separat e mortised power transfers and/or mortised automatic door bottoms wh ere they occur.
7. Where thru-wire power transfers are integral to the hinge, provide hinge with easily removable portion to allow easy a ccess to wiring connections.
08 71 00-7
8. Where models are specified that provide an integ ral wrap-around edge guard for the hinge edge of the door, provide manuf acturer’s adjustable threaded stud and machine screw mechanis m to allow the door to be adjusted within the wrap-around edge gua rd.
2.3 DOOR CLOSING DEVICES
A. Closing devices shall be products of one manufac turer.
2.4 OVERHEAD CLOSERS
A. Conform to ANSI A156.4, Grade 1.
B. Closers shall conform to the following:
1. The closer shall have minimum 50 percent adjusta ble closing force over minimum value for that closer and have adjusta ble hydraulic back check effective between 60 degrees and 85 degr ees of door opening.
2. Where specified, closer shall have hold-open fea ture.
3. Size Requirements: Provide multi-size closers, s izes 1 through 6, except where multi-size closer is not available for the required application.
4. Material of closer body shall be forged or cast.
5. Arm and brackets for closers shall be steel, mal leable iron or high strength ductile cast iron.
6. Where closers are exposed to the exterior or are mounted in rooms that experience high humidity, provide closer body and arm assembly of stainless steel material.
7. Closers shall have full size metal cover; plasti c covers will not be accepted.
8. Closers shall have adjustable hydraulic back-che ck, separate valves for closing and latching speed, adjustable back-che ck positioning valve, and adjustable delayed action valve.
9. Provide closers with any accessories required fo r the mounting application, including (but not limited to) drop pl ates, special soffit plates, spacers for heavy-duty parallel arm fifth screws, bull-nose or other regular arm brackets, longer or shorter arm assemblies, and special factory templating. Provid e special arms, drop plates, and templating as needed to allow moun ting at doors with overhead stops and/or holders.
08 71 00-8
10. Closer arms or backcheck valve shall not be use d to stop the door from overswing, except in applications where a sepa rate wall, floor, or overhead stop cannot be used.
11. Provide parallel arm closers with heavy duty ri gid arm.
12. Where closers are to be installed on the push s ide of the door, provide parallel arm type except where conditions r equire use of top jamb arm.
13. Provide all surface closers with the same body attachment screw pattern for ease of replacement and maintenance.
14. All closers shall have a 1 ½” (38mm) minimum pi ston diameter.
2.6 DOOR STOPS
A. Conform to ANSI A156.16.
B. Provide door stops wherever an opened door or an y item of hardware thereon would strike a wall, column, equipment or o ther parts of building construction. For concrete, masonry or qua rry tile construction, use lead expansion shields for mounti ng door stops.
C. Where cylindrical locks with turn pieces or push buttons occur, equip wall bumpers Type L02251 (rubber pads having concav e face) to receive turn piece or button.
D. Provide floor stops (Type L02141 or L02161 in of fice areas; Type L02121 x 3 screws into floor elsewhere. Wall bumpers, wher e used, must be installed to impact the trim or the door within the leading half of its width. Floor stops, where used, must be installed within 4-inches of the wall face and impact the door within the leadin g half of its width.
E. Where drywall partitions occur, use floor stops, Type L02141 or L02161 in office areas, Type L02121 elsewhere.
F. Provide stop Type L02011, as applicable for exte rior doors. At outswing doors where stop can be installed in concr ete, provide stop mated to concrete anchor set in 76mm (3-inch) core- drilled hole and filled with quick-setting cement.
G. Omit stops where floor mounted door holders are required and where automatic operated doors occur.
H. Provide appropriate roller bumper for each set o f doors (except where closet doors occur) where two doors would interfere with each other in swinging.
08 71 00-9
I. Provide appropriate door mounted stop on doors i n individual toilets where floor or wall mounted stops cannot be used.
J. Provide overhead surface applied stop Type C0254 1, ANSI A156.8 on patient toilet doors in bedrooms where toilet door could come in contact with the bedroom door.
K. Provide door stops on doors where combination cl oser magnetic holders are specified, except where wall stops cannot be us ed or where floor stops cannot be installed within 4-inches of the wa ll.
L. Where the specified wall or floor stop cannot be used, provide concealed overhead stops (surface-mounted where con cealed cannot be used).
2.7 OVERHEAD DOOR STOPS AND HOLDERS
A. Conform to ANSI Standard A156.8. Overhead holder s shall be of sizes recommended by holder manufacturer for each width o f door. Set overhead holders for 110 degree opening, unless limited by b uilding construction or equipment. Provide Grade 1 overhead concealed sl ide type: stop-only at rated doors and security doors, hold-open type w ith exposed hold-open on/off control at all other doors requiring ov erhead door stops.
2.9 LOCKS AND LATCHES
A. Conform to ANSI A156.2. Locks and latches for do ors 45 mm (1-3/4 inch) thick or over shall have beveled fronts. Lock cylin ders shall have not less than seven pins. Cylinders for all locksets sh all be removable core type. Cylinder shall be removable by special k ey or tool.
Construct all cores so that they will be interchang eable into the core housings of all mortise locks, rim locks, cylindric al locks, and any other type lock included in the Great Grand Master Key System.
Disassembly of lever or lockset shall not be requir ed to remove core from lockset. All locksets or latches on double doo rs with fire label shall have latch bolt with 19 mm (3/4 inch) throw, unless shorter throw allowed by the door manufacturer’s fire label. Prov ide temporary keying device or construction core to allow opening and cl osing during construction and prior to the installation of final cores.
B. In addition to above requirements, locks and lat ches shall comply with following requirements:
08 71 00-10
1. Mortise Lock and Latch Sets: Conform to ANSI/BHM A A156.13. Mortise locksets shall be series 1000, minimum Grade 2. All locksets and latchsets, except on designated doors in Psychiatri c (Mental Health) areas, shall have lever handles fabricated from cas t stainless steel. Provide sectional (lever x rose) lever desi gn. No substitute lever material shall be accepted. All locks and lat chsets shall be furnished with 122.55 mm (4-7/8-inch) curved lip st rike and wrought box. At outswing pairs with overlapping astragals, provide flat lip strip with 21mm (7/8-inch) lip-to-center dimension. Lock function
F02 shall be furnished with emergency tools/keys fo r emergency entrance. All lock cases installed on lead lined do ors shall be lead lined before applying final hardware finish. Furnis h armored fronts for all mortise locks. Where mortise locks are ins talled in high-humidity locations or where exposed to the exterior on both sides of the opening, provide non-ferrous mortise lock case.
2. Cylindrical Lock and Latch Sets: levers shall me et ADA (Americans with Disabilities Act) requirements. Cylindrical lo cksets shall be series 4000 Grade I. All locks and latchsets shall be furnished with
122.55 mm (4-7/8-inch) curved lip strike and wrough t box. At outswing pairs with overlapping astragals, provide flat lip strip with 21mm (7/8-inch) lip-to-center dimension. Prov ide lever design to match design selected by Architect or to match e xisting lever design. Where two turn pieces are specified for lo ck F76, turn piece on inside knob shall lock and unlock inside k nob, and turn piece on outside knob shall unlock outside knob whe n inside knob is in the locked position. (This function is intended to allow emergency entry into these rooms without an emergen cy key or any special tool.)
3. Auxiliary locks shall be as specified under hard ware sets and conform to ANSI A156.36.
2.11 ELECTROMAGNETIC LOCKS
A. ANSI/BHMA A156.23; electrically powered, of stre ngth and configuration indicated; with electromagnet attached to frame and armature plate attached to door. Listed under Category E in BHMA's "Certified Product
Directory."
08 71 00-11
1. Type: Full exterior or full interior, as requir ed by application indicated.
2. Strength Ranking: 1200 lbf (6672 N).
3. Inductive Kickback Peak Voltage: Not more than 53V.
4. Residual Magnetism: Not more than 4 lbf (18 N) t o separate door from magnet.
2.12 ELECTRIC STRIKES
A. ANSI/ BHMA A156.31 Grade 1.
B. General: Use fail-secure electric strikes at fi re-rated doors.
2.13 KEYS
A. Stamp all keys with change number and key set sy mbol. Furnish keys in quantities as follows:
Locks/Keys Quantity
Cylinder locks 2 keys each
Cylinder lock change key blanks
100 each different key way
Master-keyed sets 6 keys each
Grand Master sets 6 keys each
Great Grand Master set 5 keys
Control key 2 keys
B. Psychiatric keys shall be cut so that first two bittings closest to the key shoulder are shallow to provide greater strengt h at point of greatest torque.
2.15 ARMOR PLATES, KICK PLATES, MOP PLATES AND DOOR EDGING
A. Conform to ANSI Standard A156.6.
B. Provide protective plates // and door edging // as specified below:
1. Kick plates, mop plates and armor plates of meta l, Type J100 series.
2. Provide kick plates and mop plates where specifi ed. Kick plates shall be 254 mm (10 inches) or 305 mm (12 inches) h igh. Mop plates shall be 152 mm (6 inches) high. Both kick and mop plates shall be minimum 1.27 mm (0.050 inches) thick. Provide kick and mop plates beveled on all 4 edges (B4E). On push side of door s where jamb stop extends to floor, make kick plates 38 mm (1-1/2 inc hes) less than width of door, except pairs of metal doors which sh all have plates
25 mm (1 inch) less than width of each door. Extend all other kick
08 71 00-12 and mop plates to within 6 mm (1/4 inch) of each ed ge of doors. Kick and mop plates shall butt astragals. For jamb stop requirements, see specification sections pertaining to door frames.
3. Kick plates and/or mop plates are not required o n following door sides:
a. Armor plate side of doors;
b. Exterior side of exterior doors;
c. Closet side of closet doors;
d. Both sides of aluminum entrance doors.
4. Armor plates for doors are listed under Article "Hardware Sets".
Armor plates shall be thickness as noted in the har dware set, 875 mm
(35 inches) high and 38 mm (1-1/2 inches) less than width of doors, except on pairs of metal doors. Provide armor plate s beveled on all
4 edges (B4E). Plates on pairs of metal doors shal l be 25 mm (1 inch) less than width of each door. Where top of in termediate rail of door is less than 875 mm (35 inches) from door b ottom, extend armor plates to within 13 mm (1/2 inch) of top of i ntermediate rail.
On doors equipped with panic devices, extend armor plates to within
13 mm (1/2 inch) of panic bolt push bar.
5. Where louver or grille occurs in lower portion o f doors, substitute stretcher plate and kick plate in place of armor pl ate. Size of stretcher plate and kick plate shall be 254 mm (10 inches) high.
6. Provide stainless steel edge guards where so spe cified at wood doors. Provide mortised type instead of surface typ e except where door construction and/or ratings will not allow. P rovide edge guards of bevel and thickness to match wood door. Provide edge guards with factory cut-outs for door hardware that must be installed through or extend through the edge guard. Provide full-height edge guards except where door rating does no t allow; in such cases, provide edge guards to height of bottom of t ypical lockset armor front. Forward edge guards to wood door manu facturer for factory installation on doors.
2.16 EXIT DEVICES
A. Conform to ANSI Standard A156.3. Exit devices sh all be Grade 1; type and function are specified in hardware sets. Provid e flush with finished floor strikes for vertical rod exit device s in interior of building. Trim shall have cast satin stainless stee l lever handles of
08 71 00-13 design similar to locksets, unless otherwise specif ied. Provide key cylinders for keyed operating trim and, where speci fied, cylinder dogging.
B. Surface vertical rod panics shall only be provid ed less bottom rod;
provide fire pins as required by exit device and do or fire labels. Do not provide surface vertical rod panics at exterior doors.
C. Concealed vertical rod panics shall be provided less bottom rod at interior doors, unless lockable or otherwise specif ied; provide fire pins as required by exit device and door fire label s. Where concealed vertical rod panics are specified at exterior doors , provide with both top and bottom rods.
D. Where removable mullions are specified at pairs with rim panic devices, provide mullion with key-removable feature.
E. At non-rated openings with panic hardware, provi de panic hardware with key cylinder dogging feature.
F. Exit devices for fire doors shall comply with Un derwriters
Laboratories, Inc., requirements for Fire Exit Hard ware. Submit proof of compliance.
2.17 FLUSH BOLTS (LEVER EXTENSION)
A. Conform to ANSI A156.16. Flush bolts shall be Ty pe L24081 unless otherwise specified. Furnish proper dustproof strik es conforming to
ANSI A156.16, for flush bolts required on lower par t of doors.
B. Lever extension manual flush bolts shall only be used at non-fire-rated pairs for rooms only accessed by maintenance person nel.
C. Face plates for cylindrical strikes shall be rec tangular and not less than 25 mm by 63 mm (1 inch by 2-1/2 inches).
D. Friction-fit cylindrical dustproof strikes with circular face plate may be used only where metal thresholds occur.
E. Provide extension rods for top bolt where door h eight exceeds 2184 mm
(7 feet 2 inches).
2.18 FLUSH BOLTS (AUTOMATIC)
A. Conform to ANSI A156.3. Dimension of flush bolts shall conform to ANSI
A115. Bolts shall conform to Underwriters Laborator ies, Inc., requirements for fire door hardware. Flush bolts sh all automatically latch and unlatch. Furnish dustproof strikes confor ming to ANSI A156.16 for bottom flushbolt. Face plates for dustproof str ike shall be rectangular and not less than 38 mm by 90 mm (1-1/2 by 3-1/2 inches).
08 71 00-14
B. At interior doors, provide auto flush bolts less bottom bolt, unless otherwise specified, except at wood pairs with fire -rating greater than
20 minutes; provide fire pins as required by auto f lush bolt and door fire labels.
2.19 DOOR PULLS WITH PLATES
A. Conform to ANSI A156.6. Pull Type J401, 152 mm C TC (6 inches CTC) length by 19 mm (3/4 inches) diameter minimum with plate Type J302, 90 mm by 381 mm (3-1/2 inches by 15 inches), unless ot herwise specified.
Provide pull with projection of 57.2 mm (2 1/4 inch es) minimum and a clearance of 38.1 mm (1 1/2 inches) minimum. Cut pl ates of door pull plate for cylinders, or turn pieces where required.
2.20 PUSH PLATES
A. Conform to ANSI A156.6. Metal, Type J302, 203 mm (8 inches) wide by
406.4 mm (16 inches) high. Provide metal Type J302 plates 102 mm (4 inches) wide by 406.4 mm (16 inches) high where pus h plates are specified for doors with stiles less than 203 mm (8 inches) wide. Cut plates for cylinders, and turn pieces where require d.
2.21 COMBINATION PUSH AND PULL PLATES
A. Conform to ANSI 156.6. Type J303, stainless stee l 3 mm (1/8 inch) thick, 80 mm (3-1/3 inches) wide by 800 mm (16 inch es) high), top and bottom edges shall be rounded. Secure plates to woo d doors with 38 mm
(1-1/2 inch) long No. 12 wood screws. Cut plates fo r turn pieces, and cylinders where required. Pull shall be mounted dow n.
2.22 COORDINATORS
A. Conform to ANSI A156.16. Coordinators, when spec ified for fire doors, shall comply with Underwriters Laboratories, Inc., requirements for fire door hardware. Coordinator may be omitted on e xterior pairs of doors where either door will close independently re gardless of the position of the other door. Coordinator may be omit ted on interior pairs of non-labeled open where open back strike is used. Open back strike shall not be used on labeled doors. Paint co ordinators to match door frames, unless coordinators are plated. Provi de bar type coordinators, except where gravity coordinators are required at acoustic pairs. For bar type coordinators, provide filler bars for full width and, as required, brackets for push-side surface mounted closers, overhead stops, and vertical rod panic str ikes.
08 71 00-15
2.23 THRESHOLDS
A. Conform to ANSI A156.21, mill finish extruded al uminum, except as otherwise specified. In existing construction, thre sholds shall be installed in a bed of sealant with ¼-20 stainless s teel machine screws and expansion shields. In new construction, embed a luminum anchors coated with epoxy in concrete to secure thresholds. Furnish thresholds for the full width of the openings.
B. For thresholds at elevators entrances see other sections of specifications.
C. At exterior doors and any interior doors exposed to moisture, provide threshold with non-slip abrasive finish.
D. Provide with miter returns where threshold exten ds more than 12 mm (0.5 inch) beyond face of frame.
2.25 WEATHERSTRIPS (FOR EXTERIOR DOORS)
A. Conform to ANSI A156.22. Air leakage shall not t o exceed 0.50 CFM per foot of crack length (0.000774m 3/s/m).
2.26 MISCELLANEOUS HARDWARE
C. Mutes: Conform to ANSI A156.16. Provide door mut es or door silencers
Type L03011 or L03021, depending on frame material, of white or light gray color, on each steel or wood door frame, excep t at fire-rated frames, lead-lined frames and frames for sound-resi stant, lightproof and electromagnetically shielded doors. Furnish 3 m utes for single doors and 2 mutes for each pair of doors, except do uble-acting doors.
Provide 4 mutes or silencers for frames for each Du tch type door.
Provide 2 mutes for each edge of sliding door which would contact door frame.
2.30 FINISHES
A. Exposed surfaces of hardware shall have ANSI A15 6.18, finishes as specified below. Finishes on all hinges, pivots, cl osers, thresholds, etc., shall be as specified below under "Miscellane ous Finishes." For field painting (final coat) of ferrous hardware, se e Section 09 91 00, PAINTING.
B. 626 or 630: All surfaces on exterior and interio r of buildings, except where other finishes are specified.
C. Miscellaneous Finishes:
1. Hinges --exterior doors: 626 or 630.
2. Hinges --interior doors: 652 or 630.
08 71 00-16
3. Pivots: Match door trim.
4. Door Closers: Factory applied paint finish. Dull or Satin Aluminum color.
5. Thresholds: Mill finish aluminum.
6. Cover plates for floor hinges and pivots: 630.
7. Other primed steel hardware: 600.
D. Hardware Finishes for Existing Buildings: U.S. S tandard finishes shall match finishes of hardware in (similar) existing sp aces.
2.31 BASE METALS
A. Apply specified U.S. Standard finishes on differ ent base metals as following:
Finish Base Metal
652 Steel
626 Brass or bronze
630 Stainless steel
PART 3 - EXECUTION
3.1 HARDWARE HEIGHTS
A. Hardware Heights from Finished Floor:
1. Exit devices centerline of strike (where applica ble) 1024 mm (40-
5/16 inches).
2. Locksets and latch sets centerline of strike 102 4 mm (40-5/16 inches).
3. Deadlocks centerline of strike 1219 mm (48 inche s).
4. Hospital arm pull 1168 mm (46 inches) to centerl ine of bottom supporting bracket.
5. Centerline of door pulls to be 1016 mm (40 inche s).
6. Push plates and push-pull shall be 1270 mm (50 i nches) to top of plate.
7. Push-pull latch to be 1024 mm (40-5/16 inches) t o centerline of strike.
8. Locate other hardware at standard commercial hei ghts. Locate push and pull plates to prevent conflict with other hard ware.
3.2 INSTALLATION
A. Closer devices, including those with hold-open f eatures, shall be equipped and mounted to provide maximum door openin g permitted by building construction or equipment. Closers shall b e mounted on side of
08 71 00-17 door inside rooms, inside stairs, and away from cor ridors // except security bedroom, bathroom and anteroom doors which shall have closer installed parallel arm on exterior side of doors. / /. At exterior doors, closers shall be mounted on interior side. W here closers are mounted on doors they shall be mounted with sex nut s and bolts; foot shall be fastened to frame with machine screws.
B. Hinge Size Requirements:
Door Thickness Door Width Hinge Height
45 mm (1-3/4 inch) 900 mm (3 feet) and less 113 mm (4-1/2 inches)
45 mm (1-3/4 inch) Over 900 mm (3 feet) but not more than 1200 mm (4 feet)
125 mm (5 inches)
C. Hinge leaves shall be sufficiently wide to allow doors to swing clear of door frame trim and surrounding conditions.
E. Hinges Required Per Door:
Doors over 1500 mm (5 ft) high and not over 2280 mm (7 ft 6 in) high
3 butts
Doors over 2280 mm (7 feet 6 inches) high 4 butts
F. Fastenings: Suitable size and type and shall har monize with hardware as to material and finish. Provide machine screws and lead expansion shields to secure hardware to concrete, ceramic or quarry floor tile, or solid masonry. Fiber or rawl plugs and adhesives are not permitted.
All fastenings exposed to weather shall be of nonfe rrous metal.
G. After locks have been installed; show in presenc e of Resident Engineer that keys operate their respective locks in accorda nce with keying requirements. (All keys, Master Key level and above shall be sent
Registered Mail to the Medical Center Director alon g with the bitting list. Also a copy of the invoice shall be sent to t he Resident Engineer for his records.) Installation of locks which do no t meet specified keying requirements shall be considered sufficient justification for rejection and replacement of all locks installed on project.
08 71 00-18
3.3 FINAL INSPECTION
A. Installer to provide letter to VA Resident/Proje ct Engineer that upon completion, installer has visited the Project and h as accomplished the following:
1. Re-adjust hardware.
2. Evaluate maintenance procedures and recommend ch anges or additions, and instruct VA personnel.
3. Identify items that have deteriorated or failed.
4. Submit written report identifying problems.
3.4 DEMONSTRATION
A. Demonstrate efficacy of mechanical hardware and electrical, and electronic hardware systems, including adjustment a nd maintenance procedures, to satisfaction of Resident/Project Eng ineer and VA
Locksmith.
3.5 HARDWARE SETS
A. Following sets of hardware correspond to door sched ule shown on drawings.
B. Hardware Consultant working on a project will be re sponsible for providing additional information regarding these ha rdware sets. The numbers shown in the following sets come from BHMA standards.
Hardware Sets
Set: 1.0
Doors: 001-1
8 Hinge A8111 4-1/2" x 4-1/2" NRP US26D
1 Exit Device Type 8 GR1 F01 x CD US32D
1 Exit Device Type 8 GR1 F03 x CD US32D
ELECTRIC HARDWARE ABBREVIATIONS LEGEND:
ADO = Automatic Door Operator
EMCH = Electro-Mechanical Closer-Holder
MHO = Magnetic Hold-Open (wall- or floor-mounted)
08 71 00-19
2 Door Closer w/stop C02021 PT4H-BF/PT4D/PT4G AL
2 Kickplate J102 10" x 2" LDW B3E CSK US32D
1 Gasketing Pemko S88D or sim.
1 Astragal Pemko 18041CNB or sim.
2 Silencer Metal frame type
Set: 2.0
Doors: 002
5 Hinge A8112 4-1/2" x 4-1/2" US26D
1 Electrified Hinge A8112 4-1/2" x 4-1/2" ETW as req'd for device US26D
1 Manual Flush Bolt L04251 US26D
1 Dust Proof Strike L04021 w/floor plate US26D
1 Mortise Lock (storeroom) 1000 Grade 2 F07 Lever 6 26
1 Electric Strike ANSI/BHMA A156.31 Grade 1 630
2 Door Closer Reg C02011 PT4H-BF/PT4D AL
2 Kickplate J102 10" x 2" LDW B3E CSK US32D
2 Wall Stop L02251 US32D
1 Gasketing Pemko S88D or sim.
2 Astragal Pemko 18041CNB or sim.
1 Card Reader see section 281300
Set: 3.0
Doors: 101-1
4 Hinge A8111 4-1/2" x 4-1/2" NRP US32D
2 Electrified Hinge A8111 4-1/2" x 4-1/2" NRP as req’d for the device US32D
1 Exit Device w/ ELR Type 8 GR1 F03 E01 E04 x CD no trim US32D
1 Exit Device w/ ELR Type 8 GR1 F03 E01 E04 x CD US 32D
2 Door Closer w/stop C02021 PT4H-BF/PT4D/PT4G AL
2 Kickplate J102 10" x 2" LDW B3E CSK US32D
1 Gasketing Pemko S88D or sim.
08 71 00-20
2 Position Switch Securitron DPS-M-GY or sim.
1 Card Reader see section 281300
1 Power Supply By device mfr. as req'd for ELR devi ce
Set: 4.0
Doors: 101-2
6 Hinge A5111 4-1/2" x 4-1/2" NRP US32D
1 Exit Device Type 8 GR1 F03 x CD US32D
2 Door Closer w/stop C02021 PT4H-BF/PT4D/PT4G AL
2 Kickplate J102 10" x 2" LDW B3E CSK US32D
1 Gasketing Pemko S88D or sim.
Set: 5.0
Doors: 001-2
3 Hinge A8111 4-1/2" x 4-1/2" NRP US26D
1 Door Closer w/stop C02021 PT4H-BF/PT4D/PT4G AL
1 Kickplate J102 10" x 2" LDW B3E CSK US32D
1 Gasketing Pemko S88D or sim.