This submittal register outlines the required submissions for a federal contract to repair black feeder switches at Lajes Field in the Azores, Portugal. The contractor must provide all labor, materials, tools, equipment, transportation, supervision and personnel to replace all black feeder switches in the medium-voltage electrical distribution system and complete incidental related work. Key submittals include an accident prevention plan, quality control plan, equipment drawings, test reports, operation and maintenance manuals, as-built drawings and notices. The contractor schedule dates require submissions for design mixtures, samples, product data and certifications prior to the anticipated two hundred and forty calendar day period of performance.
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| 1 Statement of Work (SOW).pdf | ||
| 2 Project Drawings.pdf |
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
(a) (b) (c) (e) (f) (g) (h) (i) (j) (k) (l) (m) (n) (o) (p) (q) (r)
Line
Acti vity
Trans-mittal #
Specification Section
SD
# Submittal Description Item Submitted
Paragraph
Classificati on: GOVT or A/E Revwr Submit
Approval Needed
By
Material Needed
By Action Code
Date Of Action
Date FWD to APPR / Auth Date RCD From
CONTR
Date FWD To
Other Revwr
Date
RCD
From Other Revwr
Action Code
Date Of Action
Mailed To
CONTR/
Date RCD From
APPR
Authority Remarks
1 00 73 03 01 Preconstruction Submittals AF Form 103 1.16 G
2 01 14 00 01 Preconstruction Submittals List of Contact Personnel 1.3.1.1 G
3 01 14 00 01 Preconstruction Submittals Personnel List G
4 01 14 00 01 Preconstruction Submittals Vehicle List 1.3.1.2 G
5 01 33 00 01 Preconstruction Submittals Submittal Register 1.7 G
6 01 33 00 11 Closeout Submittals Interim DD Form 1354 1.8 G
7 01 35 26 01 Preconstruction Submittals Accident Prevention Plan (APP) 1.6 G
8 01 35 26 06 Test Reports Accident Reports 1.11.2 G
9 01 35 26 07 Certificates Standard Lift Plan 1.6.2.2 G
10 01 35 26 07 Certificates Critical Lift Plan 1.6.2.3 G
11 01 35 26 07 Certificates Activity Hazard Analysis (AHA) 1.7 G
12 01 35 26 07 Certificates Hot Work Permit 1.8.1
13 01 45 00.10 20 01 Preconstruction Submittals QC Plan 1.5 G
14 01 78 00 10 Operation and Maintenance Data Operation and Maintenance Manuals 3.2
15 01 78 00 11 Closeout Submittals DD Form 1354 1.4 G
16 01 78 00 11 Closeout Submittals As-Built Drawings 3.1 G
17 02 41 00 01 Preconstruction Submittals Demolition Plan 1.2.1 G
18 02 41 00 01 Preconstruction Submittals Existing Conditions 1.10
19 02 41 00 07 Certificates Notification 1.6 G
20 02 41 00 11 Closeout Submittals Receipts
21 03 30 00.00 10 01 Preconstruction Submittals Quality Control Plan 1.6.2 G
22 03 30 00.00 10 01 Preconstruction Submittals Laboratory Accreditation 1.6.1
23 03 30 00.00 10 01 Preconstruction Submittals Sampling Plan 3.9.5.4 G
24 03 30 00.00 10 03 Product Data Recycled Content Products Part 2
25 03 30 00.00 10 03 Product Data Cementitious Materials 2.2
26 03 30 00.00 10 03 Product Data Vapor Retarder
27 03 30 00.00 10 03 Product Data Vapor Barrier
28 03 30 00.00 10 03 Product Data Floor Finish
29 03 30 00.00 10 03 Product Data Floor Hardener 2.8
30 03 30 00.00 10 03 Product Data Chemical Admixtures 2.4
31 03 30 00.00 10 04 Samples Surface Retarder 2.4.5
32 03 30 00.00 10 05 Design Data Mixture Proportions 2.1.1 G
33 03 30 00.00 10 05 Design Data Lightweight Aggregate Concrete 3.4
34 03 30 00.00 10 06 Test Reports Mixture Proportions 2.1.1 G
APPROVING AUTHORITY
(d)
CONTRACTOR SCHEDULE
DATES
CONTRACTOR
ACTION
TITLE: Repair Black Feeder Switches
SUBMITTAL REGISTER
JOB NAME: MQNA 20-1001
LOCATION: Lajes Field
CONTRACT NO:
CONTRACTOR:
(a) (b) (c) (e) (f) (g) (h) (i) (j) (k) (l) (m) (n) (o) (p) (q) (r)
APPROVING AUTHORITY
(d)
CONTRACTOR SCHEDULE
DATES
CONTRACTOR
ACTION
TITLE: Repair Black Feeder Switches
SUBMITTAL REGISTER
JOB NAME: MQNA 20-1001
LOCATION: Lajes Field
CONTRACT NO:
CONTRACTOR:
35 03 30 00.00 10 06 Test Reports Testing and Inspection for CQC 3.9 G
36 03 30 00.00 10 06 Test Reports Fly Ash
37 03 30 00.00 10 06 Test Reports Ground Granulated Blast-Furnace (GGBF) Slag
38 03 30 00.00 10 06 Test Reports Aggregates 2.3
39 03 30 00.00 10 06 Test Reports Air Content 3.9.5.1
40 03 30 00.00 10 06 Test Reports Slump 3.9.5.2
41 03 30 00.00 10 06 Test Reports Compressive Strength 3.9.5.4
42 03 30 00.00 10 06 Test Reports Water 2.5
43 03 30 00.00 10 07 Certificates Contractor Quality Control personnel 1.6
44 03 30 00.00 10 07 Certificates Ready-Mix Plant 3.2.1
45 26 13 01 02 Shop Drawings Switchgear Drawings 1.4.1 G
46 26 13 01 03 Product Data Air Insulated Pad-mounted Switchgear 2.1 G
47 26 13 01 03 Product Data Insulated High-Voltage Connectors 2.2 G
48 26 13 01 06 Test Reports Acceptance Checks and Tests 3.4.1 G
49 26 13 01 09 Manufacturer’s Field Reports Switchgear design and production tests 2.5.1 G
50 26 13 01 10 Operation and Maintenance Data Air Insulated Pad-Mounted Switchgear Operation and Maintenance 1.5.1 G