This document is a Statement of Work (SOW) for a Signal Generator required by the Federal Communications Commission (FCC), Office of Engineering and Technology (OET), Laboratory Division. The FCC requires the Signal Generator to be tunable from 500 MHz to 71 GHz, with a maximum transmit power of 0 dBm and a dynamic range of 90 dB. The generator must support various modulation schemes including Continuous Wave, Amplitude Modulation, Frequency Modulation, FMCW, Phase Modulation, and Pulse Modulation. Specific technical requirements include the ability to generate FMCW signals with a bandwidth of at least 1 GHz at 71 GHz, and pulse modulated signals with a minimum pulse width of 50 ns at 71 GHz. The generator must also have a phase noise of -150 dBc at 71 GHz. The vendor must provide a one-year warranty, one-year traceable calibration, and certify that the product does not contain components from entities on the FCC's Covered List.

View the file

Other files for this federal contract opportunity

Other files attached to Signal Generator, newest first.
File Type Posted
273FCC24Q0033.pdf PDF

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Signal Generator

Statement of Work

June 2024

Background

The FCC, Office of Engineering and Technology (OET), Laboratory Division is responsible for the evaluation of radio frequency (RF) devices and related technologies to determine their interference risk potential and technical operating parameters in order to apply appropriate technical standards for their compliance or, in the case of new RF technologies, develop technical standards and recommend appropriate action.

The Laboratory Division designs test procedures for compliance of equipment subject to the Commission regulations and conducts tests to determine if equipment complies with applicable technical rules, procedures and standards; and it supports national and international standards activities to develop measurement procedures used to determine compliance with Commission requirements.

Objectives

The FCC requires radars and field disturbance sensors operating from 57 through 71 GHz to comply with 47 CFR 15.255. Accordingly, it is necessary for the OET Laboratory to be able to simulate these signals to develop test procedures for devices operating under these rule parts.

Scope

The FCC OET Laboratory Division shall acquire a Signal Generator which is tunable to

71 GHz to test and verify electromagnetic compatibility (EMC) procedures that are specified in the FCC rules pertaining to equipment authorization. The features of this generator include very low noise and a range of different modulation capabilities, as well as options for future extension at higher frequency ranges. Specific details of which are listed in the technical requirements.

Technical Requirements (Tasks)

The required Signal Generator shall meet, at a minimum, the requirements (below):

1. The generator shall be tunable of at least 500 MHz to 71 GHz,

2. The generator shall have a maximum tunable transmit power of ≥ 0 dBm with a dynamic range of ≥ 90dB,

3. The generator shall be capable the following modulation schemes: Continuous Wave

(CW), Amplitude Modulation (AM), Frequency Modulation (FM), FMCW (e.g., linear chirp), Phase Modulation (PM), and Pulse Modulation (P0),

a. The generator shall be capable of generating FMCW signals with a bandwidth of at least 1GHz at 71 GHz with a minimum tunable pulse width of ≤ 100ns with a duty factor of 10% at 71GHz, and

b. The generator shall be capable of generating pulse modulated signals with a minimum selectable pulse width ≤ 50 ns at 71 GHz.

4. The phase noise at 71 GHz shall be ≤ -150dBc

5. The RF output shall have a 50Ω 1.00mm (or 1.85mm with 1.85mm-to-1.00mm male-to-female adapter)

Other Requirements

1. Vendor must meet the technical requirements above

2. Vendor must provide at least one (1) year warranty with renewal options

3. Vendor must provide at least one (1) year traceable calibration

4. Vendor must verify and certify that products are not produced by and do not include components or software produced or supported by entities identified on the “Covered

List” found at (https://www.fcc.gov/supplychain/coveredlist)

Place of performance

The work will be performed at:

Federal Communications Commission

Office of Engineering and Technology

Laboratory Division

7435 Oakland Mills Road

Columbia, MD 21046 https://www.fcc.gov/supplychain/coveredlist