Business Sensitive 01/27/2022 09:42:58 AM
Page: 1 of 1 Business Sensitive
CONTINUATION REPORT
ICN KO MATL ITEM ID
36JWR21507 F08 23667
REQ DOC NO. REV CONTRACT NO. REFERENCE DOC NO. ATTACHMENT
N42158-2027ZN03 N42158- C
NAME OF OFFEROR OR CONTRACTOR
ITEM NO. SUPPLIES/SERVICES QUANTITY UNIT UNIT PRICE AMOUNT
0001 9B 4720 LL-R00-3471
HOSE ASSEMBLY
HOSE ASSEMBLY,
1-1/2" ID X 30 FT LONG AEROQUIP P/N 2661-24
(OR EQUAL),
TWO (2) EACH 1-1/2" CRES FEMALE CAMLOCK
FITTINGS & FERRULES (DIXON P/N
RC150EZNO & GAS2334NOS – NO SUBS),
& TWO (2) EACH 1-1/2” CRES CAMLOCK DUST
PLUGS (DIXON P/N 150-DP-SS) INSTALLED ON
EACH END.
2 AY
ENSURE EACH HOSE ASSEMBLY IS PROOF TESTED TO 250 +25/-0 PSIG FOR 1 TO 5 MINUTES IAW S6430-AE- TED-010. THE HOSE ASSEMBLY SHOULD NOT SHOW ANY LEAKS, SIGNS OF WEAKNESS, TWISTING, DETERIORATION, DEFORMATION, DAMAGE, BURST OR SHOW SIGNS OF FITTING SEPARATION. ENSURE EACH END OF THE HOSE ASSEMBLY IS AFFIXED WITH A PERMANENT TAG IDENTIFYING HYDROSTATIC
PROOF TEST PRESSURE, DATE OF TEST, AND TESTING ACTIVITY.
*CERTIFICATE OF COMPLIANCE REQUIRED*
*MERCURY FREE CLAUSE INVOKED*