Text version
LEVEL 1
B
EXISTING SOFFIT TO REMAIN
NEW COUNTER, TYP
NEW WALL
EXISTING WALL
NEW GFE CONSULATE TELLER
WINDOW, TYP
SS1
EXISTING WINDOW
PT1
RB1
EXISTINGNEW
EXISTING COUNTER
TYP
FWP1
4 SIM
A102 A501
A201A501
NEW FABRIC WRAPPED
PANEL APPLIED TO
EXISTING WALL
NEW FABRIC WRAPPED PANEL
APPLIED TO NEW WALL, TYP
A201A501
A201A301
TYP
TYP
RS1
NEW ROLLERSHADE, TYP
TYP
LEVEL 1
A201A301
TYP
SS1
TYP
PT1
RB1
NEW COUNTER
NEW WALL
NEW GFE CONSULATE TELLER
WINDOW, TYP
4 SIM
A102 A501
NEW FABRIC WRAPPED PANEL
APPLIED TO NEW WALL, TYP
TYP
FWP1
A201A501
A201A501
AWP1
A201A301
SIM
ACOUSTIC WALL PANELS
APPLIED TO NEW PRIVACY
WALL
NEW WING WALL
STONE TILE BASE, MATCH
EXISTING
NEW SOFFIT
TYP
PT1
CP1
TYP
RS1
NEW ROLLERSHADE, TYP
TYP
LEVEL 1
AB
EXISTING COLUMN
EXISTING SOFFIT TO REMAIN
STONE TILE BASE,
MATCH EXISTING, TYP
NEW WALL AND PRIVACY WALLS WITH
ACOUSTIC WALL PANELS; SEE PLANS
EXISTING WALL
NEW GFE CONSULATE TELLER
WINDOW
TYP
MT1
EXISTING WINDOW
TYP
CP1
A201A301
NEW WALL, TYP
COUNTERSUNK SCREWS, CENTERED
AND EVENLY SPACED
A201A501
EXISTING COUNTER
TYP
LEVEL 1
12 11
NEW GFE CONSULATE TELLER
WINDOWS
TYP
MT1
TYP
CP1
EXISTING EXTERIOR
METAL GRILLE TO REMAIN
EXISTING COLUMN
EXISTING SOFFIT TO REMAIN
STONE TILE BASE,
MATCH EXISTING, TYP
NEW WING WALLS
NEW WALL, TYP
A201A301
TYP
NEW COUNTER
DOOR AUTO-OPERATOR
LEVEL 1
EXISTING SOFFIT TO REMAIN
NEW EXTERIOR WALL
EXISTING EXTERIOR WALL
AND WING WALL
NEW GFE CONSULATE TELLER
WINDOW
SS1
EXISTING WINDOW
PT1
RB1
EXISTING NEW
FWP1
NEW ACOUSTIC WALL PANEL
APPLIED TO EXISTING WALL
FWP1
A201A501
A201A501
A201A501
NEW SOFFIT
NEW COUNTER
TYP
PT1
A201A301
TYP
RS1
NEW ROLLERSHADE, TYP
LEVEL 1
G
EXISTING COLUMN
EXISTING SOFFIT
STONE TILE BASE, MATCH EXISTING
NEW WALL
NEW PRIVACY WING WALL WITH
ACOUSTIC WALL PANELS
EXISTING WALL
NEW GFE CONSULATE TELLER
WINDOW AND TRANSACTION
DRAWER
TYP
MT1
CP1
EXISTING WINDOW
A201A501
EXISTING COUNTER
COUNTERSUNK SCREWS, CENTERED
AND EVENLY SPACED
ALIGN
(TYP)
A201A301
STAINLESS STEEL SILL
MT1
NEW STAINLESS STEEL SHELVES
171615
P
O
N
M
L
171615
P
O
N
M
L
K
J
I
1 2 3 4 5 6 7 8 9 10 11 12 13 14
H
G
F
E
D
C
B
A
1413121110987654321
A
B
C
D
E
F
G
H
I
J
K
SMITHGROUPJJR, INC.
901 K STREET NW
SUITE 400
WASHINGTON, DC 20001
T 202.842.2100 F 202.974.4500 www.smithgroup.com
CADD Plot ScaleCADD File Name
Classification
Project Number
OBO Project Number PhaseDrawing Scale
Drawing Title
United States Department of State
Washington, D.C.
Revisions
Date
Drawn By
Checked By
Sheet Number
OFFICE OF OVERSEAS BUILDINGS OPERATIONS
SAO PAULO, BRAZIL
Reviewed for Code Compliance:
OBO/PE/DE
FINALCDDDRFP
U.S. CONSULATE GENERAL
for
26915.000
CONSULAR RENOVATIONS
This document is the property of the U.S. Government. Further prohibited without the express written approval of:
reproduction and/or distribution outside the contractor team is
U.S. Department of State
Washington, D.C. 20520
ATTN: Brian Mulcahy
WARNING:
COB
13 JAN 2012
XJ-0K-T003
1 : 25
DAD
CJM
ELEVATIONS
A201
UNCLASSIFIED
UNCLASSIFIED
UNCLASSIFIED
1. REFER TO COB A602 FOR MATERIALS AND FINISH
SCHEDULE.
2. REFER TO COB Q SERIES DRAWINGS FOR EQUIPMENT
SCHEDULE.
SHEET NOTES
1 : 25
A101A201
INTERIOR WINDOW ELEVATION - NORTH
1 : 25
A101A201
INTERIOR WINDOW ELEVATION - WEST
1 : 25
A101A201
EXTERIOR WINDOW ELEVATION - SOUTH
1 : 25
A101A201
EXTERIOR WINDOW ELEVATION - EAST
1 : 25
A101A201
INTERIOR WINDOW ELEVATION - PASSBACK
1 : 25
A101A201
EXTERIOR WINDOW ELEVATION - PASSBACK
Amendment 01 24 February, 2012
GRUG-A201.dwg
EXISTING STRUCTURE
NEW LIGHT FIXTURE IN
NEW SOFFIT (SEE RCP)
NEW LIGHT FIXTURE IN
EXISTING SOFFIT
SEALANT AND BACKER ROD
A301A601
NEW GFE CONSULATE
TELLER WINDOW
STAINLESS STEEL SHELF
TO MATCH EXISTING
(FROM
WALL)
T
Y P
A
T
P R
I V
A C
Y
W I N
D O
W
ALIGN
T
Y P
A
T
P R
I V
A C
Y
W I N
D O
W
4 SIM
A102 A501
A202 A501
A301A501
A202 A501
A201A501
A201A501
TYP
A202 A501
ALIGN
FWP1
PT1
RB1
SOLID SURFACE WORK COUNTER
REVEAL IN FABRIC WRAPPED PANEL
ACCESSORY RAIL AS SCHEDULED
EQ EQ
A301A601
SIM
RS1
AWP1
A301A501
A201A501
A301A501
A201A501
SIM
A L
I G
N
ALUMINUM PLATE AT END AND TOP
MITER CHANNEL CLIPS AT CORNERS
AS SHOWN, TYP
NEW EXTERIOR BASE TILE
TO MATCH EXISTING
SIM
ST1
Q-FLOW MONITOR. COORDINATE WITH
CONSULAR AFFAIRS
EXISTING STRUCTURE
NEW LIGHT FIXTURE IN
NEW SOFFIT (SEE RCP)
NEW LIGHT FIXTURE IN
EXISTING SOFFIT
SEALANT AND BACKER ROD
A301A601
NEW GFE CONSULATE
TELLER WINDOW
STAINLESS STEEL SHELF
TO MATCH EXISTING
EXISTING WING WALL
4 SIM
A102A501
A202 A501
A301A501
A202 A501
A201A501
A201A501
TYP
A202 A501
ALIGN
FWP1
PT1
RB1
SOLID SURFACE WORK COUNTER
REVEAL IN FABRIC WRAPPED PANEL
ACCESSORY RAIL AS SCHEDULED
EQ EQ
CP1
EXISTING EXTERIOR BASE
DEAL DRAWER
A301A601
RS1
SIM
Q-FLOW MONITOR. COORDINATE WITH
CONSULAR AFFAIRS
NEW LIGHT FIXTURE IN EXISTING
SOFFIT (SEE RCP - NOTE DOES NOT
APPLY TO ACS WINDOWS)
NEW LIGHT FIXTURE IN
EXISTING SOFFIT
EXISTING GFE CONSULATE TELLER WINDOW AND
HARD LINE WALL, SOFFITS, STRUCTURE, ETC
(SHOWN SHADED FOR CLARITY)
EXTERIOR BASE TILE TO
MATCH EXISTING
A202 A501
A301A501
A202 A501
A201A501
A201A501
TYP
A202 A501
ALIGN
FWP1
PT1
RB1
EXISTING SOLID SURFACE WORK
COUNTER
REVEAL IN FABRIC WRAPPED PANEL
NEW ACCESSORY RAIL AS SCHEDULED
EQ EQ
AWP1
A301A501
A201A501
A301A501
A201A501
SIM
A L
I G
N
ALUMINUM PLATE AT END AND TOP
MITER CHANNEL CLIPS AT CORNERS
AS SHOWN, TYP
NEW FABRIC WRAPPED PANEL
APPLIED TO EXISTING WALL
SIM
NEW ACOUSTIC WALL
PANEL APPLIED TO NEW
PRIVACY WALL
SIM
SIM
SIM
SIM
SIM
EXISTING EXTERIOR BASE
TILE
EXISTING WING WALL.
PATCH AND REPAIR AS
REQUIRED
EXISTING WALL
NOTE: ONLY INTERIOR SIDE OF SECTION APPLIES AT ACS WINDOWS
(DOES NOT APPLY TO
ACS WINDOWS)
(DOES NOT APPLY TO
ACS WINDOWS)
RS1
ST1
Q-FLOW MONITOR. COORDINATE WITH
CONSULAR AFFAIRS
171615
P
O
N
M
L
171615
P
O
N
M
L
K
J
I
1 2 3 4 5 6 7 8 9 10 11 12 13 14
H
G
F
E
D
C
B
A
1413121110987654321
A
B
C
D
E
F
G
H
I
J
K
SMITHGROUPJJR, INC.
901 K STREET NW
SUITE 400
WASHINGTON, DC 20001
T 202.842.2100 F 202.974.4500 www.smithgroup.com
CADD Plot ScaleCADD File Name
Classification
Project Number
OBO Project Number PhaseDrawing Scale
Drawing Title
United States Department of State
Washington, D.C.
Revisions
Date
Drawn By
Checked By
Sheet Number
OFFICE OF OVERSEAS BUILDINGS OPERATIONS
SAO PAULO, BRAZIL
Reviewed for Code Compliance:
OBO/PE/DE
FINALCDDDRFP
U.S. CONSULATE GENERAL
for
26915.000
CONSULAR RENOVATIONS
This document is the property of the U.S. Government. Further prohibited without the express written approval of:
reproduction and/or distribution outside the contractor team is
U.S. Department of State
Washington, D.C. 20520
ATTN: Brian Mulcahy
WARNING:
COB
13 JAN 2012
XJ-0K-T003
1 : 10
DAD
CJM
SECTIONS
A301
UNCLASSIFIED
UNCLASSIFIED
UNCLASSIFIED
1. REFER TO COB A602 FOR MATERIALS AND FINISH SCHEDULE.
2. REFER TO COB Q SERIES DRAWINGS FOR EQUIPMENT
SCHEDULE.
SHEET NOTES
1 : 10
A201A301
WALL SECTION - INTERVIEW WINDOW
1 : 10
A201A301
WALL SECTION - PASSBACK WINDOW
1 : 10
A401A301
WALL SECTION - EXIST WINDOW
GRUG-A301.dwg
A
B
12 11
A201
5A201 2
A201
PRIVACY
PRIVACY
A202
A201A301
TYP
1625 1625 1625
T Y
P
T Y
P
TYP
A201A501
A201A501 2
A201A501
A202 A501
T Y
P
A L
I G
N
A L
I G
N
W
I T
H
E X
I S
T I N
G
EXISTING
COUNTER
NEW COUNTER
EXISTING WINDOW
EXISTING WINDOW
NEW WINDOW
A401A501
FABRIC WRAPPED PANELS
APPLIED TO EXISTING WALL
FABRIC WRAPPED PANELS
APPLIED TO NEW WALL
FABRIC WRAPPED PANELS
(FWP1) ALONG FULL LENGTH OF
WALL, ABOVE COUNTER ONLY.
FABRIC WRAPPED PANELS (FWP1) ALONG
FULL LENGTH OF WALL, ABOVE COUNTER
ONLY. SEE TYP DETAILS.
R
T
Y
P
E Q
E Q
EQ EQ
EQ EQ
R
A201A301
SIM
GROMMETS, TYP
GROMMET
1500TYP
A201A501
A401A501
A301A501
TYP
A301A501
SIM
A201A501
SIM
EXISTING FEBR GRILLE
TYP
GROMMET, TYP
DOOR AUTO-OPERATOR
(AT NEW WINDOWS)
TYP
(AT EXIST WINDOWS)
A401A301
THRESHOLD AS SCHEDULED
D
CONSULAR CHIEF
NIV CHIEF
E Q
E Q
E Q
E
Q E
Q
A202 3
A202
FLAT PANEL TV
EQ EQ EQ EQ
D
CONF / TRAINING
A202
EQ EQ
A202 A501
A201A501
GROMMET, TYP
WHITEBOARD
FLAT PANEL TV
SMARTBOARD
C
CONSULAR
DEPUTIES
EQ EQ
ALIGN
ALIGN WALL WITH
FACE OF COLUMN
NOTE: ENSURE THAT INTERIOR CLEAR DIMENSIONS WILL ACCOMMODATE FURNITURE
TO BE RELOCATED TO ROOM. NOTIFY PROJECT DIRECTOR OF ANY CONFLICT.
E Q
ALIGN WINDOW WITH WINDOW
ON OPPOSITE WALL
PROVIDE DOUBLE STUD FRAMING AT
CORNERS AND AT JAMB, HEAD, AND SILL
CONDITIONS OF GANGED WINDOWS
G
A201
A201
A201A501
A201A501
A301A501
SIM
NEW SOLID SURFACE WORK COUNTER
NEW STAINLESS STEEL
SHELVES, EITHER SIDE OF
TRANSACTION DRAWER
E Q
E Q
NEW FABRIC WRAPPED PANELS
APPLIED TO EXISTING WALLS, TYP
NEW PRIVACY WALLS
WITH ACOUSTIC PANELS
A201A301
F
G
CONSULAR
DEPUTIES
FRAUD
PREVENTION
ALIGN
A202
+/-1185 3000
EQ AEQ AEQ AEQ A EQ A 430 +/-491
NO FURRING ON ATTACK-SIDE WHEN
ADJACENT TO EXTERIOR WALL -
HOLD STEEL PLATE 25mm OFF
EXISTING WALL
TYP
A34
TYP
A34
EXISTING WINDOW
FABRIC WRAPPED PANELS
APPLIED TO EXISTING WALL AT
INTERIOR SIDE, BOTH FACES, TYP
SIM
A401A301
ACCESSORY RAIL AS
SCHEDULED
EXISTING COUNTER
TYPICAL AT ALL EXISTING WINDOWS
E
891011
2600 5830 5830 3660
1560CLEAR 1000CLEAR 1000CLEAR
1550CLEAR 1600CLEAR
TYP
PL2
EXISTING 2-DRAWER FILE
CABINETS (762mm WIDE), BELOW
VERTICAL SUPPORT FOR
WORKSURFACE, TYP.
EXISTING 2-DRAWER FILE
CABINETS (915mm WIDE), BELOW
TYP
PT1
EXISTING 2-DRAWER FILE CABINETS (762mm WIDE) BELOW, TYP OF 8
EXISTING 2-DRAWER FILE
CABINETS (915mm WIDE), BELOW
A401A502
A401A502
A401A502
EXISTING 2-DRAWER FILE
CABINETS (762mm WIDE)
BELOW, TYP OF 4
TRASH CAN, SEE
EQUIPMENT PLANS
PROVIDE GROMMETS AS
INDICATED
PROVIDE GROMMETS
AS INDICATED
PROVIDE GROMMETS
AS INDICATED
PROVIDE GROMMETS AS
INDICATED
TYPTYP
TYP
171615
P
O
N
M
L
171615
P
O
N
M
L
K
J
I
1 2 3 4 5 6 7 8 9 10 11 12 13 14
H
G
F
E
D
C
B
A
1413121110987654321
A
B
C
D
E
F
G
H
I
J
K
SMITHGROUPJJR, INC.
901 K STREET NW
SUITE 400
WASHINGTON, DC 20001
T 202.842.2100 F 202.974.4500 www.smithgroup.com
CADD Plot ScaleCADD File Name
Classification
Project Number
OBO Project Number PhaseDrawing Scale
Drawing Title
United States Department of State
Washington, D.C.
Revisions
Date
Drawn By
Checked By
Sheet Number
OFFICE OF OVERSEAS BUILDINGS OPERATIONS
SAO PAULO, BRAZIL
Reviewed for Code Compliance:
OBO/PE/DE
FINALCDDDRFP
U.S. CONSULATE GENERAL
for
26915.000
CONSULAR RENOVATIONS
1:50
1000 3000 50000
This document is the property of the U.S. Government. Further prohibited without the express written approval of:
reproduction and/or distribution outside the contractor team is
U.S. Department of State
Washington, D.C. 20520
ATTN: Brian Mulcahy
WARNING:
COB
13 JAN 2012
XJ-0K-T003
As indicated
DAD
CJM
ENLARGED PLANS
A401
SENSITIVE BUT UNCLASSIFIED
SENSITIVE BUT UNCLASSIFIED
SENSITIVE BUT UNCLASSIFIED
1. REFER TO COB A602 FOR MATERIALS AND FINISH SCHEDULE.
2. REFER TO COB Q SERIES DRAWINGS FOR EQUIPMENT
SCHEDULE.
SHEET NOTES
GRAPHIC LEGEND
1 : 50
A101A401
ENLARGED PLAN - NORTHWEST WINDOWS
1 : 50
A101A401
ENLARGED PLAN - PASSBACK WINDOW
1 : 50
A101A401
ENLARGED PLAN - OFFICES 103 & 104
1 : 50
A101A401
ENLARGED PLAN - DEPUTIES OFFICE
1 : 50
A101A401
ENLARGED PLAN - OFFICES 105 & 106
1 : 50
A101A401
ENLARGED PLAN - CONF/TRAINING ROOM
1 : 50
A101A401
ENLARGED PLAN - ACS WINDOW
1 : 50
A101A401
ENLARGED WORKSURFACE PLAN
GRUG-A401.dwg
TV
AV
NB
2-1/2
6 150
3 77
300500 KCMIL
600 KCMIL 300
350 KCMIL
250 KCMIL
4/0
2/0
3/0
1/0
1-1/2
1/2
3/4
(inches)
TRADE SIZE
HARD CONVERSION
(mm)
METRIC SIZE
AWG SIZE
(mm2)
METRIC/ENGLISH EQUIVALENT
WIRE
CONVERSION TABLECONVERSION TABLE
METRIC/ENGLISH EQUIVALENT
1-1/4
3-1/2
1.0
1.5
2.5
300 KCMIL
400 KCMIL
750 KCMIL 400
UV
OV
OF
UF
PR
PL
RC
LC
SINGLE RECEPTACLE - 2P, 3W, 127V, NEMA 6-20R, 380 mm AFF UON, D-DEDICATED CIRCUIT
DUPLEX RECEPTACLE - 2P, 3W, 127V, NEMA 6-20R, 380mm AFF UON, D-DEDICATED CIRCUIT
WP - WEATHERPROOF, GFCI - GROUND FAULT CIRCUIT INTERRUPTER, IG - ISOLATED GROUND
JUNCTION BOX, WALL,CEILING OR FLUSH-FLOOR MOUNTED (MOUNTING HEIGHT AS SHOWN ON PLANS)
THE SWITCH (TYPICAL FOR ALL LIGHTING SWITCHES), 1220mm AFF, 127VAC RATED
SINGLE POLE TOGGLE SWITCH - SUBSCRIPT INDICATES FIXTURES CONTROLLED BY
DRAWING NOTE (APPLIES ONLY TO THE DRAWING ON WHICH IT IS SEEN), NUMBER IDENTIFIES NOTE
EXIT LIGHT - DARKENED SECTION INDICATES FACE WITH DIRECTIONAL ARROWS
EXTERIOR LIGHT POLE AND CONCRETE BASE WITH SINGLE MOUNTED FIXTURE OF TYPE NOTED
EXTERIOR LIGHT POLE AND CONCRETE BASE WITH TWIN MOUNTED FIXTURES OF TYPE NOTED
SELF-CONTAINED, BATTERY POWERED EMERGENCY LIGHT WITH TWIN LAMPHEAD
LIGHTING FIXTURE, WALL MOUNTED - SEE LIGHTING FIXTURE SCHEDULE
UPPER CASE - FIXTURE TYPE (TYPICAL FOR ALL LIGHTING FIXTURES)
380mm AFF UON
DUPLEX RECEPTACLE - 2P, 3W, 20A, 127V, NEMA 6-20R
PHOTOELECTRIC CONTROL FOR SITE LIGHTING
J J J
GFCI
IG
WP
DIMMER SWITCH, 1220mm AFF, 127VAC, 50 HZ RATED
THREE WAY TOGGLE SWITCH, 1220mm AFF, 127VAC RATED
AS INDICATED - SEE LIGHTING FIXTURE SCHEDULE
- SEE LIGHTING FIXTURE SCHEDULE
S
SD
Sa
ELECTRICAL SYMBOLS
LIGHTING FIXTURE WITH BUILT IN BATTERY PACK
NUMBER - INDICATES BRANCH CIRCUIT
(TYPICAL FOR ALL LIGHTING FIXTURES)
LOWER CASE - INDICATES CONTROLLING SWITCHES
SEE LIGHTING FIXTURE SCHEDULES
a 1
G
LIGHTING FIXTURE
SHUNT TRIP COIL
RACEWAY (2) - 4 mm2 + 4 mm2 GND IN 20 mm EMT UON
HANDHOLE, UNDERGROUND WITH LOCKABLE STEEL COVER (GROUND TEST WELL)
MANHOLE, UNDERGROUND WITH LOCKABLE STEEL COVER
TRANSFORMER - VOLTAGE, POWER, ISOLATION AND "K" RATINGS AS NOTED.
HOMERUN TO PANELBOARD. ARROWS INDICATE NUMBER OF CIRCUITS.
VOLTMETER
AMMETER
UNDERGROUND NEW WORK
HH
T
MH
CONDUIT TURNING UP
CONDUIT TURNING DOWN
OCCUPANCY SENSOR, WALL OR CEILING MOUNTED. AN 'H' SUBSCRIPT, IF
PRESENT, INDICATES AN OCCUPANCY SENSOR THAT IS CONFIGURED FOR A
HALLWAY; A '2' SUBSCRIPT, IF PRESENT INDICATES AN 2 CIRCUIT OCCUPANCY
SENSOR.
V
OS
NONFUSED DISCONNECT SWITCH
FLOOR MOUNTED (FLUSH OR STUBBED UP AS NOTED)
DUPLEX RECEPTACLE - 2P, 3W, 15A (AS NOTED), NEMA 6-20R, 127V,
FUSED DISCONNECT SWITCH
SINGLE PHASE ELECTRICAL MOTOR - INSIDE NUMERAL INDICATES HORSEPOWER
PANELBOARD, SURFACE OR RECESSED MOUNTED
MOTOR SWITCH, HORSEPOWER RATED, 127VAC - 1HP MIN
MS
F
- UNLESS OTHERWISE NOTED
- SECONDS
- POLYVINYL CHLORIDE
- SYMMETRICAL
- TELEPHONE TERMINAL BOARD
- WEATHER PROOF
- RIGID GALVANIZED STEEL
- RECEPTACLE
- TRANSFORMER
- VOLT AMPERES
LTG
- LIGHTING
- CIRCUIT
CKT
- VOLTAGE
V
- PHASE
- NOT TO SCALE
- NOT IN CONTRACT
- NATIONAL ELECTRICAL MANUFACTURER'S ASSOCIATION
- NON-FUSED SAFETY SWITCH
- MOUNTING HEIGHT
- MAIN LUGS ONLY
- MANHOLE
- MECHANICAL
- MAIN DISTRIBUTION PANEL
- MOTOR CIRCUIT PROTECTOR
- MAIN CIRCUIT BREAKER
- NATIONAL ELECTRICAL CODE
- FULL LOAD AMPERES
- FUSED OR FUSIBLE
- EXISTING TO REMAIN
- ELECTRICAL METALLIC TUBING
- CURRENT TRANSFORMER
- ELECTRIC/ ELECTRICAL
- FIRE ALARM CONTROL PANEL
- ELECTRIC WATER COOLER
ETR
FACP
FO
FLA
EX, EXIST
EWC
F
- FIBER OPTIC
- EXISTING
EF
EQUIP
ELEC
EMT
DWG
CT
CLG
- EXHAUST FAN
- EQUIPMENT
- DRAWING
- CEILING
NEC
NTS
Ø OR PH
NFSS
NIC
NEMA
MECH
MLO
MT HT
MH
MCP
MDP
MCB
XFMR
W
WP
VA
- WIRE
- THOUSAND CIRCULAR MILS
- JUNCTION BOX
- HAND-OFF-AUTOMATIC
- GROUND FAULT CIRCUIT INTERRUPTER
- GROUND WIRE
- KILOVAR HOUR
- GROUND
- KILOVOLT-AMPERES
- HERTZ
- HORSE POWER
- GOVERNMENT FURNISHED EQUIPMENT
ABBREVIATIONS
- CIRCUIT BREAKER
- AMPERE INTERRUPTING CAPACITY
- ABOVE FINISHED GRADE
- AIR HANDLING UNIT
- AMERICAN WIRE GAUGE
- AUTOMATIC TRANSFER SWITCH
- ABOVE FINISHED FLOOR
AHU
AWG
BLDG
C
CB
ASYM
ATS
AIC
- BUILDING
- CONDUIT
- ASYMMETRICAL
A
AFF
AFG
ACT
- AMPERES
- ACOUSTICS TILE
GW
JB
KVA
KVARH
KCMIL
HP
HZ
HOA
GFE
GND
GFCI
RGS
TEL
UON
TTB
TYP
SEC
RM
SYM
- TELEPHONE
- TYPICAL
- ROOM
P
PNL
PVC
RECPT
- POLE
- PANEL
CONTACT, NORMALLY OPEN
CONTACT, NORMALLY CLOSED
'L' COIL LATCHES AND 'R' COIL RESETS
RELAY, LATCHING TYPE
PANEL LAMP, LARGE, NEON, COLOR AS NOTED
WHEN COIL IS ENERGIZED
RELAY, MOMENTARY TYPE, NORMALLY CLOSED CONTACTS OPEN ONLY
TIME IS REACHED THE CONTACTS CLOSE AND REMAIN CLOSED UNTIL THE COIL IS DE-ENERGIZED
RELAY, ON DELAY TYPE, WHEN COIL IS ENERGIZED, AN ADJUSTABLE TIMER STARTS. WHEN THE SET
RELAY, ONE SHOT TYPE. CONTROL VOLTAGE IS CONSTANTLY APPLIED. WHEN AN EXTERNAL
DRY CONTACT IS CLOSED, THE RELAY INTERNAL CONTACTS CLOSE AND A TIMER STARTS. WHEN
THE SET TIME IS REACHED THE CONTACTS OPEN REGARDLESS OF THE STATUS OF THE EXTERNAL
DRY CONTACT
SHUNT CLOSE COIL
H
VOLTAGE REGULATOR, TYPE AND RATINGS AS NOTED
V
R
GENERATOR, SIZE AND RATINGS AS NOTED
G
SURGE SUPPRESSOR/LIGHTNING ARRESTER
CURRENT TRANSFORMER
POTENTIAL TRANSFORMER
MOLDED CASE CIRCUIT BREAKER
INSULATED CASE, POWER TYPE CIRCUIT BREAKER
G
I
S
L INSULATED CASE, POWER TYPE CIRCUIT BREAKER WITH SOLID STATE TRIP UNIT
'L'- LONG TIME 'S'- SHORT TIME 'I'- INSTANTANEOUS 'G'- GROUND FAULT
MEDIUM VOLTAGE FUSED SWITCH
UNDER VOLTAGE RELAY
OVER FREQUENCY RELAY
PHASE LOSS RELAY
DRIVEN GROUND ROD, COPPER CLAD, 3048 mm X 19 mm
MTS
- MANUAL TRANSFER SWITCH
- POTENTIAL TRANSFORMER
PT
AIR TERMINAL
GROUND CONNECTION
CR
- CONTROL RELAY
TIME CLOCK
CONTROL RELAY, MOMENTARY, WITH ONE NORMALLY
OPEN AND ONE NORMALLY CLOSED CONTACT
THREE PHASE ELECTRICAL MOTOR - INSIDE NUMERAL INDICATES HORSEPOWER
M
METER, DIGITAL WITH KWH, KVARH, KW, KVAR, KVA, KVAH, PF
AND PEAK KVA AND KVAR MEASUREMENTS
- KILOWATT
KW
- KILOWATT HOUR
KWH
- POWER FACTORPF
QUADRUPLEX RECEPTACLE - 2P, 3W, 127V, NEMA 6-20R, 380 mm AFF UON
UNDERGROUND BARE COPPER GROUND CONDUCTOR, SIZE AS NOTEDG
OVER VOLTAGE RELAY
UNDER FREQUENCY RELAY
PHASE REVERSAL/REVERSE PHASE ROTATION RELAY
- COPPER
CU
- HANDHOLEHH
- KILOVOLT AMP REACTIVEKVAR
- FUSED SAFETY SWITCHFSS
- WITH
W/
TELECOMMUNICATIONS SYMBOLS
FLOOR SLEEVES
CONDUIT IN WALL OR CEILING
CABLE TRAY SIZE AND TYPE PER DRAWINGS. SOLID LINE
INDICATES LOCATION ABOVE CEILING; DASHED LINE
INDICATES LOCATION BELOW FLOOR.
GROUNDING BUS BAR
19mm FIRE TREATED PLYWOOD
TV OUTLET AT 380 mm A.F.F.
AUDIOVISUAL OUTLET AT 380 mm A.F.F. UON
NIGHT BELL AT 150mm BELOW FINISHED CEILING (GFE).
RECESSED VOICE OUTLET AT 380 mm A.F.F. UON
- SHUNT CLOSE
SC
- SHUNT TRIP
ST
- MINUTES
MIN
TR - TELEPHONE ROOM
ENCLOSED CIRCUIT BREAKER
PROVIDE STANDARD RJ-45 JACK.
GFGI - GOVERNMENT FURNISHED GOVERNMENT INSTALLED
CEILING FAN WITH LIGHT KIT
J WALL MOUNTED JUNCTION BOX
OVERHEAD/DOWNLIGHT (SEE LIGHTING FIXTURE SCHEDULE FOR DETAILS)
GRID TYPE (SEE LIGHTING FIXTURE SCHEDULE FOR DETAILS)
COMBINATION STARTER WITH ADJUSTABLE, MAGNETIC TRIP ONLY, CIRCUIT
BREAKER DISCONNECT AND ADJUSTABLE, SOLID STATE, OVERLOAD RELAY
CFCI
- CONTRACTOR FURNISHED
CONTRACTOR INSTALLED
- CONTRACTOR FURNISHED
GOVERNMENT INSTALLED
CFGI
OR GOVERNMENT FURNISHED CONTRACTOR INSTALLED
1 NUMERAL INDICATES NEMA SIZE
RECESSED VOICE OUTLET AT 1220 mm A.F.F. UON
V
MINIMUM AREA = 0.3 m
WP
WP - WEATHERPROOF
MOV
- METAL OXIDE VARISTOR
- UNITED STATES GOVERNMENTUSG
TIME DELAY RELAY
WALL MOUNTED PUSH BUTTON FOR AUTOMATIC DOOR OPERATOR
STANDARD VOICE AND DATA OUTLET @ 380 mm AFF UON.
FLOOR MOUNTED VOICE & DATA OUTLET
WP
OUTLET PHONE IN WEATHER PROOF BOX
MINIMUM OF 90-MINUTE BACK-UP
M
L
R
OD
OS
1 2
3 4
TC
CR
ST
SC
A
2-1/2
6 155
3 78
1-1/2
1/2
3/4
(inches)
TRADE SIZE
METRIC SIZE
(mm)
CONDUIT
CONVERSION TABLE
METRIC/ENGLISH EQUIVALENT
1-1/4
3-1/2
OS
PH
CEILING MOUNTED PHOTOSENSOR
6 BUTTON CONTROL KEYPAD WITH ETCHED NAMEPLATE
SCS
P P
POWER SERVICE FITTING (FLOOR/WALL) MOUNTED FOR CONNECTION TO
FURNITURE SYSTEM AS SPECIFIED.
D D
JUNCTION BOX FLOOR OR WALL MOUNTED FOR
CONNECTION TO FURNITURE SYSTEM.
FBX
FLOOR BOX ("X" DENOTES TYPE AS SPECIFIED: "P" INDICATES POKE-THRU, "F" INDICATES FLUSH)
DUPLEX RECEPTACLE - 2P, 3W, 127V, NEMA 6-20R, 1219mm AFF UON, D-DEDICATED CIRCUIT
PB PULL BOX
XX SPECIAL PURPOSE RECEPTACLE. TYPE AS INDICATED ON DRAWINGS.
COORDINATE RECEPTACLE TYPE WITH ACTUAL EQUIPMENT PRIOR TO INSTALLATION.
3-POSITION WALL SWITCH FOR MOTORIZED PROJECTION SCREEN
PS
S
IC CONSULAR TELLER WINDOW INTERCOM
WD WD TELLER FINGERPRINT STATION AND JUNCTION BOX
CK
MICROPHONE AND KEYPAD FOR TELLER WINDOW
X
CEILING MOUNTED
DUPLEX RECEPTACLE - 2P, 3W, 15A (AS NOTED), NEMA 6-20R, 127V,
CEILING MOUNTED VOICE & DATA OUTLET
P/D POWER AND DATA POLE FEEDING SYSTEMS FURNITURE
FPP
FIBER PATCH PANEL
CPP
COPPER PATCH PANEL
BSW
BACKBONE SWITCH
CSW
COPPER SWITCH
RECLOSING RELAY
171615
P
O
N
M
L
171615
P
O
N
M
L
K
J
I
1 2 3 4 5 6 7 8 9 10 11 12 13 14
H
G
F
E
D
C
B
A
1413121110987654321
A
B
C
D
E
F
G
H
I
J
K
SMITHGROUPJJR, INC.
901 K STREET NW
SUITE 400
WASHINGTON, DC 20001
T 202.842.2100 F 202.974.4500 www.smithgroup.com
CADD Plot ScaleCADD File Name
Classification
Project Number
OBO Project Number PhaseDrawing Scale
Drawing Title
United States Department of State
Washington, D.C.
Revisions
Date
Drawn By
Checked By
Sheet Number
OFFICE OF OVERSEAS BUILDINGS OPERATIONS
SAO PAULO, BRAZIL
Reviewed for Code Compliance:
OBO/PE/DE
FINALCDDDRFP
U.S. CONSULATE GENERAL
for
26915.000
CONSULAR RENOVATIONS
This document is the property of the U.S. Government. Further prohibited without the express written approval of:
reproduction and/or distribution outside the contractor team is
U.S. Department of State
Washington, D.C. 20520
ATTN: Brian Mulcahy
WARNING:
COB
13 JAN 2012
XJ-0K-T003
NONE
MK
TF
ELECTRICAL SYMBOLS
E001
UNCLASSIFIED
UNCLASSIFIED
UNCLASSIFIED
GRUG-E001.dwg
ICIC
CKWD
ICIC
CKWD
ICIC
CKWD
ICIC
CKWD
ICIC
CKWD
ICIC
CKWD
ICIC
CKWD
ICIC
CKWD
ICIC
CKWD
ICIC
CKWD
ICIC
CKWD
ICIC
CKWD
ICIC
CKWD
ICIC
CKWD
ICIC
CKWD
ICIC
CKWD
ICIC
CKWD
ICIC
CKWD
ICIC
CKWD
ICIC
CKWD
ICIC
CKWD
ICIC
CKWD
ICCK
WD IC
ICCK
WD IC
ICCK
WD IC
21042184
2184H
2184J
21322133
A
B
C
D
E
F
G
12 1234567891011
CONSULAR CHIEF
NIV CHIEF
GENERAL WORK
AREA
ARSO
CONSULAR
DEPUTIES
CONF / TRAINING
CONSULAR
DEPUTIES
PRIVACY
PRIVACY
EXISTING
TELECOM
EXISTING
ELECTRICAL
EXISTING KITCHEN
EXISTING PBX
EXISTING MAIN
TERMINAL SPACE
EXISTING
MECHANICAL
OPEN OFFICE
OPEN OFFICE
RECEPTION
ET101---
E401
ET101---
EXISTING 610MM
BASKET CABLE TRAY
TO REMAIN
TYP.
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
EXISTING 305MM
BASKET CABLE TRAY
TO REMAIN
EXISTING 305MM
BASKET CABLE TRAY
TO REMAIN
EXISTING 305MM
BASKET CABLE TRAY
TO REMAIN
EXISTING 610MM
BASKET CABLE TRAY
TO REMAIN
EXISTING 305MM
BASKET CABLE TRAY
TO REMAIN
E401
TYP.
300mm X
300mm J-BOX
171615
P
O
N
M
L
171615
P
O
N
M
L
K
J
I
1 2 3 4 5 6 7 8 9 10 11 12 13 14
H
G
F
E
D
C
B
A
1413121110987654321
A
B
C
D
E
F
G
H
I
J
K
SMITHGROUPJJR, INC.
901 K STREET NW
SUITE 400
WASHINGTON, DC 20001
T 202.842.2100 F 202.974.4500 www.smithgroup.com
CADD Plot ScaleCADD File Name
Classification
Project Number
OBO Project Number PhaseDrawing Scale
Drawing Title
United States Department of State
Washington, D.C.
Revisions
Date
Drawn By
Checked By
Sheet Number
OFFICE OF OVERSEAS BUILDINGS OPERATIONS
SAO PAULO, BRAZIL
Reviewed for Code Compliance:
OBO/PE/DE
FINALCDDDRFP
U.S. CONSULATE GENERAL
for
26915.000
CONSULAR RENOVATIONS
0 2000 5000 10000
1:100
This document is the property of the U.S. Government. Further prohibited without the express written approval of:
reproduction and/or distribution outside the contractor team is
U.S. Department of State
Washington, D.C. 20520
ATTN: Brian Mulcahy
WARNING:
COB
13 JAN 2012
XJ-0K-T003
1 : 100
MK
TF
CONSULATE INTERCOM/QUEUING
SYSTEM PLAN
ET101
SENSITIVE BUT UNCLASSIFIED
SENSITIVE BUT UNCLASSIFIED
SENSITIVE BUT UNCLASSIFIED
A. INTENT OF THE DRAWINGS - THE DRAWINGS ARE DIAGRAMMATIC
AND SHOW THE GENERAL LOCATION OF OUTLETS, RACEWAYS, AND
EQUIPMENT. THE DRAWINGS DO NOT SHOW ALL NECESSARY
OFFSETS, JUNCTION BOXES, CABLETRAY TRANSITIONS, AND
ADJUSTMENTS NECESSITATED BY COORDINATION WITH OTHER
TRADES. THE COST OF ALL OFFSETS, RACEWAY COMPONENTS,
ACCESSORIES, AND ADJUSTMENTS NECESSITATED BY
COORDINATION WITH OTHER TRADES SHALL BE INCLUDED IN THE
CONTRACTOR'S BID.
B. COORDINATION WITH OTHER TRADES - EXAMINE AND REVIEW THE
CONTRACT DOCUMENTS OF ALL DIVISIONS IN ORDER TO
COORDINATE THE INSTALLATION OF WORK. USE DIMENSIONED
ARCHITECTURAL AND STRUCTURAL CONTRACT DRAWINGS TO VERIFY
THE SPACE NECESSARY FOR LOCATING OUTLETS, RACEWAYS, AND
EQUIPMENT. USE FIELD MEASUREMENTS TO VERIFY DIMENSIONS
WHERE AREAS ARE CONGESTED, AND EXACT LOCATION IS CRITICAL
TO ASSURE PROPER INSTALLATION. COORDINATION SHALL INCLUDE,
BUT SHALL NOT BE LIMITED TO, VERIFYING THE LOCATION AND SIZE
OF OPENINGS PENETRATIONS IN FLOORS, WALLS, PARTITIONS,
CEILINGS, AND ROOFS WITH THE INSTALLING TRADES; ALLOCATION
OF SPACE WITH OTHER TRADES INSTALLING WORK IN CHASES,
SHAFTS, CEILING INTERSTITIAL SPACES, AND EQUIPMENT SPACES;
AND THE PHASING OF INSTALLATION WORK WITH THAT OF OTHER
TRADES.
C. WORKMANSHIP - INSTALL ALL WORK IN A WORKMANLIKE MANNER
THAT PROVIDES A FIRST CLASS COMPLETED INSTALLATION. MOVE,
CORRECT, AND REPLACE ANY WORK DEEMED UNACCEPTABLE AT
THE DISCRESION OF THE ARCHITECT /ENGINEER.
D. EQUIPMENT - INSTALL ALL EQUIPMENT IN ACCORDANCE WITH THE
MANUFACTURER'S PRINTED INSTALLATION INSTRUCTIONS, THE
SPECIFICATIONS, AND APPROVED SHOP DRAWINGS. PROVIDE
SERVICE AND OPERATING CLEARANCES AROUND ALL SIDES OF
EACH PIECE OF EQUIPMENT IN ACCORDANCE WITH REGULATORY
REQUIREMENTS, MANUFACTURER'S PRINTED REQUIREMENTS AND
RECOMMENDATIONS.
E. SEE DETAILS 3 AND 4 ON SHEET ET502 FOR BALLISTIC RESISTANT
CONDUIT PENETRATIONS AT ALL FEBR WALLS.
F. ALL DEVICES WITH AN "E" SUBSCRIPT ARE EXISTING TO REMAIN.
MAINTAIN ALL WIRING AND CIRCUIT CONTINUITY DURING
CONSTRUCTION.
1 : 100
ET101
CONSULATE INTERCOM/QUEUING SYSTEM PLAN
SHEET NOTES
KEYNOTES
E401 PROVIDE CONSULAR SECTION INTERCOM AND QUEUING SYSTEM
DEVICES AT NEW WINDOWS. COORDINATE AND CONNECT TO
EXISTING QUEUING AND INTERCOM SYSTEM FROM EXISTING TO
REMAIN WINDOWS TO NEW WINDOWS. MATCH EXISTING SYSTEM
AND MEET SED 2011 REQUIREMENTS FOR IC SYSTEM. ALL
CONDUIT PENETRATIONS SHALL MEET FEBR REQUIREMENTS SEE
DETAILS ON SHEET ET501.
Amendment 01 24 February, 2012
GRUG-ET101.dwg
= QUEUING SYSTEM WIRE
= CABLE TRAY
21042184
2184H
2184J
21322133
A
B
C
D
E
F
G
12 1234567891011
102B
102A
A
B
B
B B
B
B
A
D
A
A201
A101---
A201
A
CONSULAR CHIEF
NIV CHIEF
GENERAL WORK
AREA
ARSO
CONSULAR
DEPUTIES
CONF / TRAINING
CONSULAR
DEPUTIES
PRIVACY
PRIVACY
EXISTING
TELECOM
EXISTING
ELECTRICAL
EXISTING KITCHEN
EXISTING PBX
EXISTING MAIN
TERMINAL SPACE
EXISTING
MECHANICAL
OPEN OFFICE
OPEN OFFICE
RECEPTION
0A3A
0A3A
0A3A
0A3B
0A3A
0A3A
TYP
0B3A
A
A201
A201
A101A401
A101A401
A101A401
A101A401
0A3B
A101A401
A101A401
A2
A201
A202
A6
A10
D
119A
FRAUD
PREVENTION
EXISTING
KITCHEN
A202
A202
C
A202
EXISTING
TELECOM
EXISTING EMR
EXISTING
STORAGE
EXISTING
CORRIDOR
104A
A
0A3B
A15
A15A15 A15 A15 8 A101A401
A101A501
A24 A24 A21
A23
A22
A20
A20
A20
A22
A24
A21
A101A401
TYP
EXISTING
ELECTICAL ROOM
TYP
A30
TYP
A30
A
A
A
A
WAITING ROOM
GENERAL WORK
AREA
A32
A31A31
A202
A
D
A2
0A3B
A
A30
A34
A33
A34A34
TYP
A34
EXISTING WALL / DOOR / WINDOW
TO REMAIN
EXISTING WALL / DOOR / WINDOW
TO BE DEMOLISHED
NEW CONSTRUCTION
NOT IN SCOPE
171615
P
O
N
M
L
171615
P
O
N
M
L
K
J
I
1 2 3 4 5 6 7 8 9 10 11 12 13 14
H
G
F
E
D
C
B
A
1413121110987654321
A
B
C
D
E
F
G
H
I
J
K
SMITHGROUPJJR, INC.
901 K STREET NW
SUITE 400
WASHINGTON, DC 20001
T 202.842.2100 F 202.974.4500 www.smithgroup.com
CADD Plot ScaleCADD File Name
Classification
Project Number
OBO Project Number PhaseDrawing Scale
Drawing Title
United States Department of State
Washington, D.C.
Revisions
Date
Drawn By
Checked By
Sheet Number
OFFICE OF OVERSEAS BUILDINGS OPERATIONS
SAO PAULO, BRAZIL
Reviewed for Code Compliance:
OBO/PE/DE
FINALCDDDRFP
U.S. CONSULATE GENERAL
for
26915.000
CONSULAR RENOVATIONS
0 2000 5000 10000
1:100
This document is the property of the U.S. Government. Further prohibited without the express written approval of:
reproduction and/or distribution outside the contractor team is
U.S. Department of State
Washington, D.C. 20520
ATTN: Brian Mulcahy
WARNING:
COB
13 JAN 2012
XJ-0K-T003
1 : 100
DAD
CJM
FIRST FLOOR PLAN
A101
SENSITIVE BUT UNCLASSIFIED
SENSITIVE BUT UNCLASSIFIED
SENSITIVE BUT UNCLASSIFIED
1 : 100
A101
NEW CONSTRUCTION - FIRST FLOOR
1. DOORS WITH TAGS ARE ENTIRELY NEW. REFER TO DOOR
SCHEDULE FOR MORE INFORMATION. DOORS WITHOUT TAGS
ARE EXISTING TO REMAIN.
2. SEE COB A601 FOR SCHEDULES.
3. SEE COB A102 FOR REFLECTED CEILING PLAN.
4. REFER TO COB Q SERIES DRAWINGS FOR EQUIPMENT PLANS.
SHEET NOTES
KEYNOTES
GRAPHIC LEGEND
A2 REPLACE PORTION OF WALL WITH CONSTRUCTION MATCHING
EXISTING.
A6 EXISTING UNDER FLOOR MANHOLE ACCESS TO DRAINAGE SYSTEM.
A10 WORK IN THIS AREA LIMITED TO NEW WORKSTATIONS AND THEIR
SUPPORT.
A15 NEW COUNTERTOP/WORKSURFACE
A20 PROVIDE NEW TRANSITION STRIP AT DOOR PER DETAIL 5A/A601,
CARPET TO CARPET.
A21 PROVIDE NEW THRESHOLD AT DOOR PER DETAIL 5B/A601, CARPET
TO CONCRETE AT FIRE RATED DOOR.
A22 PROVIDE NEW TRANSITION STRIP AT DOOR PER DETAIL 5C/A601,
CARPET TO RESILIENT TILE.
A23 PROVIDE NEW THRESHOLD AT DOOR PER DETAIL 5D/A601, CARPET
TO CONCRETE, EXTERIOR.
A24 PROVIDE NEW THRESHOLD STRIP AT DOOR PER DETAIL 5E/A601,
CARPET TO CONCRETE, INTERIOR.
A30 NEW 15MIN FE/BR HARDLINE WALL - REF SHEET LS101 FOR DETAILS
A31 NEW PRIVACY WALL AT ALL EXISTING WINDOWS. SEE DETAIL 3/A301.
A32 NEW ACOUSTIC TREATMENT AT ALL EXISTING PRIVACY PANELS.
A33 NEW EXTERIOR WALL [CP1], DRAINAGE PANEL [DP1], AIR BARRIER
[AB1], ON 20MM EXTERIOR GRADE PLYWOOD AND METAL FRAMING -
REFERENCE DETAIL 9/A601 (SIM).
A34 EXISTING FURNITURE, RELOCATED. REFER TO SHEET Q101 FOR
ADDITIONAL INFORMATION.
Amendment 01 24 February, 2012 CCD-01 10 October, 2012
GRUG-A101.dwg
AutoCAD SHX Text
BIX BLOCK BY POST
AutoCAD SHX Text
CABLE RUN IN EXISTING CABLE TRAY
AutoCAD SHX Text
BIX BLOCK BY POST
ICIC
CKWD
ICIC
CKWD
ICIC
CKWD
ICIC
CKWD
ICIC
CKWD
ICIC
CKWD
ICIC
CKWD
ICIC
CKWD
ICIC
CKWD
ICIC
CKWD
ICIC
CKWD
ICIC
CKWD
ICIC
CKWD
ICIC
CKWD
ICIC
CKWD
ICIC
CKWD
ICIC
CKWD
ICIC
CKWD
ICIC
CKWD
ICIC
CKWD
ICIC
CKWD
ICIC
CKWD
ICCK
WD IC
ICCK
WD IC
ICCK
WD IC
21042184
2184H
2184J
21322133
A
B
C
D
E
F
G
12 1234567891011
CONSULAR CHIEF
NIV CHIEF
GENERAL WORK
AREA
ARSO
CONSULAR
DEPUTIES
CONF / TRAINING
CONSULAR
DEPUTIES
PRIVACY
PRIVACY
EXISTING
TELECOM
EXISTING
ELECTRICAL
EXISTING KITCHEN
EXISTING PBX
EXISTING MAIN
TERMINAL SPACE
EXISTING
MECHANICAL
OPEN OFFICE
OPEN OFFICE
RECEPTION
ET101---
E401
ET101---
EXISTING 610MM
BASKET CABLE TRAY
TO REMAIN
TYP.
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
EXISTING 305MM
BASKET CABLE TRAY
TO REMAIN
EXISTING 305MM
BASKET CABLE TRAY
TO REMAIN
EXISTING 305MM
BASKET CABLE TRAY
TO REMAIN
EXISTING 610MM
BASKET CABLE TRAY
TO REMAIN
EXISTING 305MM
BASKET CABLE TRAY
TO REMAIN
E401
TYP.
300mm X
300mm J-BOX
171615
P
O
N
M
L
171615
P
O
N
M
L
K
J
I
1 2 3 4 5 6 7 8 9 10 11 12 13 14
H
G
F
E
D
C
B
A
1413121110987654321
A
B
C
D
E
F
G
H
I
J
K
SMITHGROUPJJR, INC.
901 K STREET NW
SUITE 400
WASHINGTON, DC 20001
T 202.842.2100 F 202.974.4500 www.smithgroup.com
CADD Plot ScaleCADD File Name
Classification
Project Number
OBO Project Number PhaseDrawing Scale
Drawing Title
United States Department of State
Washington, D.C.
Revisions
Date
Drawn By
Checked By
Sheet Number
OFFICE OF OVERSEAS BUILDINGS OPERATIONS
SAO PAULO, BRAZIL
Reviewed for Code Compliance:
OBO/PE/DE
FINALCDDDRFP
U.S. CONSULATE GENERAL
for
26915.000
CONSULAR RENOVATIONS
0 2000 5000 10000
1:100
This document is the property of the U.S. Government. Further prohibited without the express written approval of:
reproduction and/or distribution outside the contractor team is
U.S. Department of State
Washington, D.C. 20520
ATTN: Brian Mulcahy
WARNING:
COB
13 JAN 2012
XJ-0K-T003
1 : 100
MK
TF
CONSULATE INTERCOM/QUEUING
SYSTEM PLAN
ET101
SENSITIVE BUT UNCLASSIFIED
SENSITIVE BUT UNCLASSIFIED
SENSITIVE BUT UNCLASSIFIED
A. INTENT OF THE DRAWINGS - THE DRAWINGS ARE DIAGRAMMATIC
AND SHOW THE GENERAL LOCATION OF OUTLETS, RACEWAYS, AND
EQUIPMENT. THE DRAWINGS DO NOT SHOW ALL NECESSARY
OFFSETS, JUNCTION BOXES, CABLETRAY TRANSITIONS, AND
ADJUSTMENTS NECESSITATED BY COORDINATION WITH OTHER
TRADES. THE COST OF ALL OFFSETS, RACEWAY COMPONENTS,
ACCESSORIES, AND ADJUSTMENTS NECESSITATED BY
COORDINATION WITH OTHER TRADES SHALL BE INCLUDED IN THE
CONTRACTOR'S BID.
B. COORDINATION WITH OTHER TRADES - EXAMINE AND REVIEW THE
CONTRACT DOCUMENTS OF ALL DIVISIONS IN ORDER TO
COORDINATE THE INSTALLATION OF WORK. USE DIMENSIONED
ARCHITECTURAL AND STRUCTURAL CONTRACT DRAWINGS TO VERIFY
THE SPACE NECESSARY FOR LOCATING OUTLETS, RACEWAYS, AND
EQUIPMENT. USE FIELD MEASUREMENTS TO VERIFY DIMENSIONS
WHERE AREAS ARE CONGESTED, AND EXACT LOCATION IS CRITICAL
TO ASSURE PROPER INSTALLATION. COORDINATION SHALL INCLUDE,
BUT SHALL NOT BE LIMITED TO, VERIFYING THE LOCATION AND SIZE
OF OPENINGS PENETRATIONS IN FLOORS, WALLS, PARTITIONS,
CEILINGS, AND ROOFS WITH THE INSTALLING TRADES; ALLOCATION
OF SPACE WITH OTHER TRADES INSTALLING WORK IN CHASES,
SHAFTS, CEILING INTERSTITIAL SPACES, AND EQUIPMENT SPACES;
AND THE PHASING OF INSTALLATION WORK WITH THAT OF OTHER
TRADES.
C. WORKMANSHIP - INSTALL ALL WORK IN A WORKMANLIKE MANNER
THAT PROVIDES A FIRST CLASS COMPLETED INSTALLATION. MOVE,
CORRECT, AND REPLACE ANY WORK DEEMED UNACCEPTABLE AT
THE DISCRESION OF THE ARCHITECT /ENGINEER.
D. EQUIPMENT - INSTALL ALL EQUIPMENT IN ACCORDANCE WITH THE
MANUFACTURER'S PRINTED INSTALLATION INSTRUCTIONS, THE
SPECIFICATIONS, AND APPROVED SHOP DRAWINGS. PROVIDE
SERVICE AND OPERATING CLEARANCES AROUND ALL SIDES OF
EACH PIECE OF EQUIPMENT IN ACCORDANCE WITH REGULATORY
REQUIREMENTS, MANUFACTURER'S PRINTED REQUIREMENTS AND
RECOMMENDATIONS.
E. SEE DETAILS 3 AND 4 ON SHEET ET502 FOR BALLISTIC RESISTANT
CONDUIT PENETRATIONS AT ALL FEBR WALLS.
F. ALL DEVICES WITH AN "E" SUBSCRIPT ARE EXISTING TO REMAIN.
MAINTAIN ALL WIRING AND CIRCUIT CONTINUITY DURING
CONSTRUCTION.
1 : 100
ET101
CONSULATE INTERCOM/QUEUING SYSTEM PLAN
SHEET NOTES
KEYNOTES
E401 PROVIDE CONSULAR SECTION INTERCOM AND QUEUING SYSTEM
DEVICES AT NEW WINDOWS. COORDINATE AND CONNECT TO
EXISTING QUEUING AND INTERCOM SYSTEM FROM EXISTING TO
REMAIN WINDOWS TO NEW WINDOWS. MATCH EXISTING SYSTEM
AND MEET SED 2011 REQUIREMENTS FOR IC SYSTEM. ALL
CONDUIT PENETRATIONS SHALL MEET FEBR REQUIREMENTS SEE
DETAILS ON SHEET ET501.
Amendment 01 24 February, 2012
GRUG-ET101.dwg
= QUEUING SYSTEM WIRE
= CABLE TRAY
UTP CABLE
4 PAIRS CAT-6
4 PAIRS CAT-6
RJ-45 TYPE JACK FOR
FOR SPARE
RJ-45 TYPE JACK FOR VOICE
RJ-45 TYPE JACK FOR SPARE
SPARE CA WINDOW ONLY
FOR VOICE
4 PAIRS CAT-6
4 PAIRS CAT-6
RJ-45 TYPE JACK FOR DATA
SINGLE GANG FACEPLATE
NEW CABLE TRAY
MIN 35 mm CONDUIT FROM
WORKSTATION WALL OUTLET
SPARE CABLE STATE LAN CABLE VOICE CABLE
SECTION SECTION SECTION
BUSHING
SPARE CABLE
SECTION
MIN 41 mm CONDUIT FROM
WORKSTATION POKE-THRU
EXIST.
MTS
TERMINATION
FIBER
CABINET
LAN
SWITCH
CABINET
LAN EQUIPMENT
FIBER
SWITCH
TERMINATION
CABINET
LAN
EQUIPMENT CABINET
PATCH PANEL
WORKSTATION
TYPICAL
OUTLET
TR 110
FOFO FO FO
PROVIDE NEW MULTIMODE FIBER OPTIC CABLES
F/O F/0
PP PP
FO
PROVIDE NEW MULTIMODE FIBER OPTIC CABLES
TO LAN RACK
TYPE 1
CA WINDOW
TYPICAL
OUTLET
2 - CAT 6 CABLE
TYPE 2
1 - CAT 6 SPARE
2 - CAT 6 SPARE
2 - CAT 6 CABLE
EXIST.EXIST.
HORIZONTAL
BIX
BLOCK
TR 110
BIX
BLOCK
RISER
BLOCK
DISTRIBUTION
BIX
BLOCK
BIX
PANEL
PROTECTOR
PRIMARY
PANEL
PROTECTOR
PRIMARY
SWITCH
PBX
BLOCK
BIX
BLOCK
BIX
OUTLET
TYPICAL
WORKSTATION
RISER
MTS
PBX
NEW 100 PAIR CAT3
UTP RISER CABLE
CAT6
UTP CABLE
500 PAIR OSP CABLE
FROM CAMPUS DEMARC
SEE SITE RISER DIAGRAM
TO ANCILLARY BUILDINGS
ON SHEET ET5.05.
DASHED LINE INDICATES BY OTHERS
UCR
TSEF
PP
F/O
UTP CAT6 CABLES
(INTERNET) FROM WS
(1) 100-PR UTP CAT3
CABLES FROM PBX
4-PR UTP CAT6 CABLES (VOICE)
FROM WS
NEW NETWORK 48 PORT
NETWORK SWITCH TO MATCH
EXISTING.
NEW NETWORK 48 PORT PATCH
PANEL
NEW NETWORK 48 PORT
NETWORK SWITCH TO MATCH
EXISTING.
NEW NETWORK 48 PORT
NETWORK SWITCH TO MATCH
EXISTING.
NEW NETWORK 48 PORT PATCH
PANEL
NEW NETWORK 48 PORT PATCH
PANEL
PP1
PP2
PP3
PP4
PP5
PP6
PP7
PP8
PP9
PP10
PP11
TO MAIN TERMINAL SPACE
LEVEL 1
FPP
BSW
CSW
CPP
EXISTING CABLE
TRAY
TYPICAL
WORKSTATION
WALL OUTLET
35mm CONDUIT
LOCATE CONDUIT WITHIN
WALLS AND COLUMNS TO
NEAREST ACCESSIBLE CEILING
TYPICAL SYSTEMS
FURNITURE
POWER/DATA POLE
FEED
SYSTEMS
FURNITURE
WORKSTATION
NEW AS REQ'D
NEW AS REQ'D
NEW AS
REQ'D
NEW AS
REQ'D
NEW FIBER CABLE. PROVIDE
(1) 6-STRAND 62.5/125um MM
FIBER OPTIC WITH SC
TERMINATIONS TO MATCH
EXISTING
GROUND BAR
TELECOMMUNICATIONS
WORKSTATION
TERMINATION FIELD
HORIZONTAL CABLE
CAT 6 VOICE CABLE
TO WORKSTATION OUTLET
300 PAIR BIX
RISER CABLE
TERMINATION FIELD
300 PAIR BIX
PAINT TO MATCH WALLS.
EX PLYWOOD BACKBOARD.
PAINT WITH FIRE RETARDANT
102 mm SLEEVES
171615
P
O
N
M
L
171615
P
O
N
M
L
K
J
I
1 2 3 4 5 6 7 8 9 10 11 12 13 14
H
G
F
E
D
C
B
A
1413121110987654321
A
B
C
D
E
F
G
H
I
J
K
SMITHGROUPJJR, INC.
901 K STREET NW
SUITE 400
WASHINGTON, DC 20001
T 202.842.2100 F 202.974.4500 www.smithgroup.com
CADD Plot ScaleCADD File Name
Classification
Project Number
OBO Project Number PhaseDrawing Scale
Drawing Title
United States Department of State
Washington, D.C.
Revisions
Date
Drawn By
Checked By
Sheet Number
OFFICE OF OVERSEAS BUILDINGS OPERATIONS
SAO PAULO, BRAZIL
Reviewed for Code Compliance:
OBO/PE/DE
FINALCDDDRFP
U.S. CONSULATE GENERAL
for
26915.000
CONSULAR RENOVATIONS
This document is the property of the U.S. Government. Further prohibited without the express written approval of:
reproduction and/or distribution outside the contractor team is
U.S. Department of State
Washington, D.C. 20520
ATTN: Brian Mulcahy
WARNING:
COB
13 JAN 2012
XJ-0K-T003
As indicated
CS
TF
TELECOMMUNICATIONS DETAILS
ET501
UNCLASSIFIED
UNCLASSIFIED
UNCLASSIFIED
NONE
ET501
CABLE TRAY PATHWAY DETAIL
NONE
ET501
CONNECTIVITY DIAGRAM - LAN & SPARE
NONE
ET501
CONNECTIVITY DIAGRAM - VOICE
NONE
ET501
VOICE PUNCH DOWN DIAGRAM
NONE
ET501
RACK AND CROSS CONNECT DETAILS
NONE
ET501
TYPICAL DESK WORKSTATION OUTLET
NONE
ET501
DATA ONE-LINE DIAGRAM & WORKSTATIONS CABLE
PLAN
GRUG-ET501.dwg
| Sheets and Views |
| Attachment A-18-A201 |
| Attachment A-20-A301 |
| Attachment A-21-A401 |
| Attachment A-53-E001 |
| Attachment A-58.1-ET101_10445 |
| Attachment A-58.2-ET101A_16760 |
| Attachment A-61.1-ET501A_16743 |
| Attachment A-61.2-ET501B_16760 |
File details come from the government source that posted it. Updated .