Attachment_A_Existing_Infrastructure.pdf

PDF 4 MB Posted

Attached to
Microphone Service Installations Federal contract opportunity
Solicitation number
19BR9320Q0007
Issued by
Department of State

View the file

Other files for this federal contract opportunity

Other files attached to Microphone Service Installations, newest first.
File Type Posted
RFQ19BR9320Q007_Formal Questions -Answers.pdf PDF
Attachment_B_OBO_Design_Standards.pdf PDF
RFQ19BR9320Q0007_Consular Microphones.pdf PDF
SF1449_Consular Microp System.pdf PDF

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

LEVEL 1

B

EXISTING SOFFIT TO REMAIN

NEW COUNTER, TYP

NEW WALL

EXISTING WALL

NEW GFE CONSULATE TELLER

WINDOW, TYP

SS1

EXISTING WINDOW

PT1

RB1

EXISTINGNEW

EXISTING COUNTER

TYP

FWP1

4 SIM

A102 A501

A201A501

NEW FABRIC WRAPPED

PANEL APPLIED TO

EXISTING WALL

NEW FABRIC WRAPPED PANEL

APPLIED TO NEW WALL, TYP

A201A501

A201A301

TYP

TYP

RS1

NEW ROLLERSHADE, TYP

TYP

LEVEL 1

A201A301

TYP

SS1

TYP

PT1

RB1

NEW COUNTER

NEW WALL

NEW GFE CONSULATE TELLER

WINDOW, TYP

4 SIM

A102 A501

NEW FABRIC WRAPPED PANEL

APPLIED TO NEW WALL, TYP

TYP

FWP1

A201A501

A201A501

AWP1

A201A301

SIM

ACOUSTIC WALL PANELS

APPLIED TO NEW PRIVACY

WALL

NEW WING WALL

STONE TILE BASE, MATCH

EXISTING

NEW SOFFIT

TYP

PT1

CP1

TYP

RS1

NEW ROLLERSHADE, TYP

TYP

LEVEL 1

AB

EXISTING COLUMN

EXISTING SOFFIT TO REMAIN

STONE TILE BASE,

MATCH EXISTING, TYP

NEW WALL AND PRIVACY WALLS WITH

ACOUSTIC WALL PANELS; SEE PLANS

EXISTING WALL

NEW GFE CONSULATE TELLER

WINDOW

TYP

MT1

EXISTING WINDOW

TYP

CP1

A201A301

NEW WALL, TYP

COUNTERSUNK SCREWS, CENTERED

AND EVENLY SPACED

A201A501

EXISTING COUNTER

TYP

LEVEL 1

12 11

NEW GFE CONSULATE TELLER

WINDOWS

TYP

MT1

TYP

CP1

EXISTING EXTERIOR

METAL GRILLE TO REMAIN

EXISTING COLUMN

EXISTING SOFFIT TO REMAIN

STONE TILE BASE,

MATCH EXISTING, TYP

NEW WING WALLS

NEW WALL, TYP

A201A301

TYP

NEW COUNTER

DOOR AUTO-OPERATOR

LEVEL 1

EXISTING SOFFIT TO REMAIN

NEW EXTERIOR WALL

EXISTING EXTERIOR WALL

AND WING WALL

NEW GFE CONSULATE TELLER

WINDOW

SS1

EXISTING WINDOW

PT1

RB1

EXISTING NEW

FWP1

NEW ACOUSTIC WALL PANEL

APPLIED TO EXISTING WALL

FWP1

A201A501

A201A501

A201A501

NEW SOFFIT

NEW COUNTER

TYP

PT1

A201A301

TYP

RS1

NEW ROLLERSHADE, TYP

LEVEL 1

G

EXISTING COLUMN

EXISTING SOFFIT

STONE TILE BASE, MATCH EXISTING

NEW WALL

NEW PRIVACY WING WALL WITH

ACOUSTIC WALL PANELS

EXISTING WALL

NEW GFE CONSULATE TELLER

WINDOW AND TRANSACTION

DRAWER

TYP

MT1

CP1

EXISTING WINDOW

A201A501

EXISTING COUNTER

COUNTERSUNK SCREWS, CENTERED

AND EVENLY SPACED

ALIGN

(TYP)

A201A301

STAINLESS STEEL SILL

MT1

NEW STAINLESS STEEL SHELVES

171615

P

O

N

M

L

171615

P

O

N

M

L

K

J

I

1 2 3 4 5 6 7 8 9 10 11 12 13 14

H

G

F

E

D

C

B

A

1413121110987654321

A

B

C

D

E

F

G

H

I

J

K

SMITHGROUPJJR, INC.

901 K STREET NW

SUITE 400

WASHINGTON, DC 20001

T 202.842.2100 F 202.974.4500 www.smithgroup.com

CADD Plot ScaleCADD File Name

Classification

Project Number

OBO Project Number PhaseDrawing Scale

Drawing Title

United States Department of State

Washington, D.C.

Revisions

Date

Drawn By

Checked By

Sheet Number

OFFICE OF OVERSEAS BUILDINGS OPERATIONS

SAO PAULO, BRAZIL

Reviewed for Code Compliance:

OBO/PE/DE

FINALCDDDRFP

U.S. CONSULATE GENERAL

for

26915.000

CONSULAR RENOVATIONS

This document is the property of the U.S. Government. Further prohibited without the express written approval of:

reproduction and/or distribution outside the contractor team is

U.S. Department of State

Washington, D.C. 20520

ATTN: Brian Mulcahy

WARNING:

COB

13 JAN 2012

XJ-0K-T003

1 : 25

DAD

CJM

ELEVATIONS

A201

UNCLASSIFIED

UNCLASSIFIED

UNCLASSIFIED

1. REFER TO COB A602 FOR MATERIALS AND FINISH

SCHEDULE.

2. REFER TO COB Q SERIES DRAWINGS FOR EQUIPMENT

SCHEDULE.

SHEET NOTES

1 : 25

A101A201

INTERIOR WINDOW ELEVATION - NORTH

1 : 25

A101A201

INTERIOR WINDOW ELEVATION - WEST

1 : 25

A101A201

EXTERIOR WINDOW ELEVATION - SOUTH

1 : 25

A101A201

EXTERIOR WINDOW ELEVATION - EAST

1 : 25

A101A201

INTERIOR WINDOW ELEVATION - PASSBACK

1 : 25

A101A201

EXTERIOR WINDOW ELEVATION - PASSBACK

Amendment 01 24 February, 2012

GRUG-A201.dwg

EXISTING STRUCTURE

NEW LIGHT FIXTURE IN

NEW SOFFIT (SEE RCP)

NEW LIGHT FIXTURE IN

EXISTING SOFFIT

SEALANT AND BACKER ROD

A301A601

NEW GFE CONSULATE

TELLER WINDOW

STAINLESS STEEL SHELF

TO MATCH EXISTING

(FROM

WALL)

T

Y P

A

T

P R

I V

A C

Y

W I N

D O

W

ALIGN

T

Y P

A

T

P R

I V

A C

Y

W I N

D O

W

4 SIM

A102 A501

A202 A501

A301A501

A202 A501

A201A501

A201A501

TYP

A202 A501

ALIGN

FWP1

PT1

RB1

SOLID SURFACE WORK COUNTER

REVEAL IN FABRIC WRAPPED PANEL

ACCESSORY RAIL AS SCHEDULED

EQ EQ

A301A601

SIM

RS1

AWP1

A301A501

A201A501

A301A501

A201A501

SIM

A L

I G

N

ALUMINUM PLATE AT END AND TOP

MITER CHANNEL CLIPS AT CORNERS

AS SHOWN, TYP

NEW EXTERIOR BASE TILE

TO MATCH EXISTING

SIM

ST1

Q-FLOW MONITOR. COORDINATE WITH

CONSULAR AFFAIRS

EXISTING STRUCTURE

NEW LIGHT FIXTURE IN

NEW SOFFIT (SEE RCP)

NEW LIGHT FIXTURE IN

EXISTING SOFFIT

SEALANT AND BACKER ROD

A301A601

NEW GFE CONSULATE

TELLER WINDOW

STAINLESS STEEL SHELF

TO MATCH EXISTING

EXISTING WING WALL

4 SIM

A102A501

A202 A501

A301A501

A202 A501

A201A501

A201A501

TYP

A202 A501

ALIGN

FWP1

PT1

RB1

SOLID SURFACE WORK COUNTER

REVEAL IN FABRIC WRAPPED PANEL

ACCESSORY RAIL AS SCHEDULED

EQ EQ

CP1

EXISTING EXTERIOR BASE

DEAL DRAWER

A301A601

RS1

SIM

Q-FLOW MONITOR. COORDINATE WITH

CONSULAR AFFAIRS

NEW LIGHT FIXTURE IN EXISTING

SOFFIT (SEE RCP - NOTE DOES NOT

APPLY TO ACS WINDOWS)

NEW LIGHT FIXTURE IN

EXISTING SOFFIT

EXISTING GFE CONSULATE TELLER WINDOW AND

HARD LINE WALL, SOFFITS, STRUCTURE, ETC

(SHOWN SHADED FOR CLARITY)

EXTERIOR BASE TILE TO

MATCH EXISTING

A202 A501

A301A501

A202 A501

A201A501

A201A501

TYP

A202 A501

ALIGN

FWP1

PT1

RB1

EXISTING SOLID SURFACE WORK

COUNTER

REVEAL IN FABRIC WRAPPED PANEL

NEW ACCESSORY RAIL AS SCHEDULED

EQ EQ

AWP1

A301A501

A201A501

A301A501

A201A501

SIM

A L

I G

N

ALUMINUM PLATE AT END AND TOP

MITER CHANNEL CLIPS AT CORNERS

AS SHOWN, TYP

NEW FABRIC WRAPPED PANEL

APPLIED TO EXISTING WALL

SIM

NEW ACOUSTIC WALL

PANEL APPLIED TO NEW

PRIVACY WALL

SIM

SIM

SIM

SIM

SIM

EXISTING EXTERIOR BASE

TILE

EXISTING WING WALL.

PATCH AND REPAIR AS

REQUIRED

EXISTING WALL

NOTE: ONLY INTERIOR SIDE OF SECTION APPLIES AT ACS WINDOWS

(DOES NOT APPLY TO

ACS WINDOWS)

(DOES NOT APPLY TO

ACS WINDOWS)

RS1

ST1

Q-FLOW MONITOR. COORDINATE WITH

CONSULAR AFFAIRS

171615

P

O

N

M

L

171615

P

O

N

M

L

K

J

I

1 2 3 4 5 6 7 8 9 10 11 12 13 14

H

G

F

E

D

C

B

A

1413121110987654321

A

B

C

D

E

F

G

H

I

J

K

SMITHGROUPJJR, INC.

901 K STREET NW

SUITE 400

WASHINGTON, DC 20001

T 202.842.2100 F 202.974.4500 www.smithgroup.com

CADD Plot ScaleCADD File Name

Classification

Project Number

OBO Project Number PhaseDrawing Scale

Drawing Title

United States Department of State

Washington, D.C.

Revisions

Date

Drawn By

Checked By

Sheet Number

OFFICE OF OVERSEAS BUILDINGS OPERATIONS

SAO PAULO, BRAZIL

Reviewed for Code Compliance:

OBO/PE/DE

FINALCDDDRFP

U.S. CONSULATE GENERAL

for

26915.000

CONSULAR RENOVATIONS

This document is the property of the U.S. Government. Further prohibited without the express written approval of:

reproduction and/or distribution outside the contractor team is

U.S. Department of State

Washington, D.C. 20520

ATTN: Brian Mulcahy

WARNING:

COB

13 JAN 2012

XJ-0K-T003

1 : 10

DAD

CJM

SECTIONS

A301

UNCLASSIFIED

UNCLASSIFIED

UNCLASSIFIED

1. REFER TO COB A602 FOR MATERIALS AND FINISH SCHEDULE.

2. REFER TO COB Q SERIES DRAWINGS FOR EQUIPMENT

SCHEDULE.

SHEET NOTES

1 : 10

A201A301

WALL SECTION - INTERVIEW WINDOW

1 : 10

A201A301

WALL SECTION - PASSBACK WINDOW

1 : 10

A401A301

WALL SECTION - EXIST WINDOW

GRUG-A301.dwg

A

B

12 11

A201

5A201 2

A201

PRIVACY

PRIVACY

A202

A201A301

TYP

1625 1625 1625

T Y

P

T Y

P

TYP

A201A501

A201A501 2

A201A501

A202 A501

T Y

P

A L

I G

N

A L

I G

N

W

I T

H

E X

I S

T I N

G

EXISTING

COUNTER

NEW COUNTER

EXISTING WINDOW

EXISTING WINDOW

NEW WINDOW

A401A501

FABRIC WRAPPED PANELS

APPLIED TO EXISTING WALL

FABRIC WRAPPED PANELS

APPLIED TO NEW WALL

FABRIC WRAPPED PANELS

(FWP1) ALONG FULL LENGTH OF

WALL, ABOVE COUNTER ONLY.

FABRIC WRAPPED PANELS (FWP1) ALONG

FULL LENGTH OF WALL, ABOVE COUNTER

ONLY. SEE TYP DETAILS.

R

T

Y

P

E Q

E Q

EQ EQ

EQ EQ

R

A201A301

SIM

GROMMETS, TYP

GROMMET

1500TYP

A201A501

A401A501

A301A501

TYP

A301A501

SIM

A201A501

SIM

EXISTING FEBR GRILLE

TYP

GROMMET, TYP

DOOR AUTO-OPERATOR

(AT NEW WINDOWS)

TYP

(AT EXIST WINDOWS)

A401A301

THRESHOLD AS SCHEDULED

D

CONSULAR CHIEF

NIV CHIEF

E Q

E Q

E Q

E

Q E

Q

A202 3

A202

FLAT PANEL TV

EQ EQ EQ EQ

D

CONF / TRAINING

A202

EQ EQ

A202 A501

A201A501

GROMMET, TYP

WHITEBOARD

FLAT PANEL TV

SMARTBOARD

C

CONSULAR

DEPUTIES

EQ EQ

ALIGN

ALIGN WALL WITH

FACE OF COLUMN

NOTE: ENSURE THAT INTERIOR CLEAR DIMENSIONS WILL ACCOMMODATE FURNITURE

TO BE RELOCATED TO ROOM. NOTIFY PROJECT DIRECTOR OF ANY CONFLICT.

E Q

ALIGN WINDOW WITH WINDOW

ON OPPOSITE WALL

PROVIDE DOUBLE STUD FRAMING AT

CORNERS AND AT JAMB, HEAD, AND SILL

CONDITIONS OF GANGED WINDOWS

G

A201

A201

A201A501

A201A501

A301A501

SIM

NEW SOLID SURFACE WORK COUNTER

NEW STAINLESS STEEL

SHELVES, EITHER SIDE OF

TRANSACTION DRAWER

E Q

E Q

NEW FABRIC WRAPPED PANELS

APPLIED TO EXISTING WALLS, TYP

NEW PRIVACY WALLS

WITH ACOUSTIC PANELS

A201A301

F

G

CONSULAR

DEPUTIES

FRAUD

PREVENTION

ALIGN

A202

+/-1185 3000

EQ AEQ AEQ AEQ A EQ A 430 +/-491

NO FURRING ON ATTACK-SIDE WHEN

ADJACENT TO EXTERIOR WALL -

HOLD STEEL PLATE 25mm OFF

EXISTING WALL

TYP

A34

TYP

A34

EXISTING WINDOW

FABRIC WRAPPED PANELS

APPLIED TO EXISTING WALL AT

INTERIOR SIDE, BOTH FACES, TYP

SIM

A401A301

ACCESSORY RAIL AS

SCHEDULED

EXISTING COUNTER

TYPICAL AT ALL EXISTING WINDOWS

E

891011

2600 5830 5830 3660

1560CLEAR 1000CLEAR 1000CLEAR

1550CLEAR 1600CLEAR

TYP

PL2

EXISTING 2-DRAWER FILE

CABINETS (762mm WIDE), BELOW

VERTICAL SUPPORT FOR

WORKSURFACE, TYP.

EXISTING 2-DRAWER FILE

CABINETS (915mm WIDE), BELOW

TYP

PT1

EXISTING 2-DRAWER FILE CABINETS (762mm WIDE) BELOW, TYP OF 8

EXISTING 2-DRAWER FILE

CABINETS (915mm WIDE), BELOW

A401A502

A401A502

A401A502

EXISTING 2-DRAWER FILE

CABINETS (762mm WIDE)

BELOW, TYP OF 4

TRASH CAN, SEE

EQUIPMENT PLANS

PROVIDE GROMMETS AS

INDICATED

PROVIDE GROMMETS

AS INDICATED

PROVIDE GROMMETS

AS INDICATED

PROVIDE GROMMETS AS

INDICATED

TYPTYP

TYP

171615

P

O

N

M

L

171615

P

O

N

M

L

K

J

I

1 2 3 4 5 6 7 8 9 10 11 12 13 14

H

G

F

E

D

C

B

A

1413121110987654321

A

B

C

D

E

F

G

H

I

J

K

SMITHGROUPJJR, INC.

901 K STREET NW

SUITE 400

WASHINGTON, DC 20001

T 202.842.2100 F 202.974.4500 www.smithgroup.com

CADD Plot ScaleCADD File Name

Classification

Project Number

OBO Project Number PhaseDrawing Scale

Drawing Title

United States Department of State

Washington, D.C.

Revisions

Date

Drawn By

Checked By

Sheet Number

OFFICE OF OVERSEAS BUILDINGS OPERATIONS

SAO PAULO, BRAZIL

Reviewed for Code Compliance:

OBO/PE/DE

FINALCDDDRFP

U.S. CONSULATE GENERAL

for

26915.000

CONSULAR RENOVATIONS

1:50

1000 3000 50000

This document is the property of the U.S. Government. Further prohibited without the express written approval of:

reproduction and/or distribution outside the contractor team is

U.S. Department of State

Washington, D.C. 20520

ATTN: Brian Mulcahy

WARNING:

COB

13 JAN 2012

XJ-0K-T003

As indicated

DAD

CJM

ENLARGED PLANS

A401

SENSITIVE BUT UNCLASSIFIED

SENSITIVE BUT UNCLASSIFIED

SENSITIVE BUT UNCLASSIFIED

1. REFER TO COB A602 FOR MATERIALS AND FINISH SCHEDULE.

2. REFER TO COB Q SERIES DRAWINGS FOR EQUIPMENT

SCHEDULE.

SHEET NOTES

GRAPHIC LEGEND

1 : 50

A101A401

ENLARGED PLAN - NORTHWEST WINDOWS

1 : 50

A101A401

ENLARGED PLAN - PASSBACK WINDOW

1 : 50

A101A401

ENLARGED PLAN - OFFICES 103 & 104

1 : 50

A101A401

ENLARGED PLAN - DEPUTIES OFFICE

1 : 50

A101A401

ENLARGED PLAN - OFFICES 105 & 106

1 : 50

A101A401

ENLARGED PLAN - CONF/TRAINING ROOM

1 : 50

A101A401

ENLARGED PLAN - ACS WINDOW

1 : 50

A101A401

ENLARGED WORKSURFACE PLAN

GRUG-A401.dwg

TV

AV

NB

2-1/2

6 150

3 77

300500 KCMIL

600 KCMIL 300

350 KCMIL

250 KCMIL

4/0

2/0

3/0

1/0

1-1/2

1/2

3/4

(inches)

TRADE SIZE

HARD CONVERSION

(mm)

METRIC SIZE

AWG SIZE

(mm2)

METRIC/ENGLISH EQUIVALENT

WIRE

CONVERSION TABLECONVERSION TABLE

METRIC/ENGLISH EQUIVALENT

1-1/4

3-1/2

1.0

1.5

2.5

300 KCMIL

400 KCMIL

750 KCMIL 400

UV

OV

OF

UF

PR

PL

RC

LC

SINGLE RECEPTACLE - 2P, 3W, 127V, NEMA 6-20R, 380 mm AFF UON, D-DEDICATED CIRCUIT

DUPLEX RECEPTACLE - 2P, 3W, 127V, NEMA 6-20R, 380mm AFF UON, D-DEDICATED CIRCUIT

WP - WEATHERPROOF, GFCI - GROUND FAULT CIRCUIT INTERRUPTER, IG - ISOLATED GROUND

JUNCTION BOX, WALL,CEILING OR FLUSH-FLOOR MOUNTED (MOUNTING HEIGHT AS SHOWN ON PLANS)

THE SWITCH (TYPICAL FOR ALL LIGHTING SWITCHES), 1220mm AFF, 127VAC RATED

SINGLE POLE TOGGLE SWITCH - SUBSCRIPT INDICATES FIXTURES CONTROLLED BY

DRAWING NOTE (APPLIES ONLY TO THE DRAWING ON WHICH IT IS SEEN), NUMBER IDENTIFIES NOTE

EXIT LIGHT - DARKENED SECTION INDICATES FACE WITH DIRECTIONAL ARROWS

EXTERIOR LIGHT POLE AND CONCRETE BASE WITH SINGLE MOUNTED FIXTURE OF TYPE NOTED

EXTERIOR LIGHT POLE AND CONCRETE BASE WITH TWIN MOUNTED FIXTURES OF TYPE NOTED

SELF-CONTAINED, BATTERY POWERED EMERGENCY LIGHT WITH TWIN LAMPHEAD

LIGHTING FIXTURE, WALL MOUNTED - SEE LIGHTING FIXTURE SCHEDULE

UPPER CASE - FIXTURE TYPE (TYPICAL FOR ALL LIGHTING FIXTURES)

380mm AFF UON

DUPLEX RECEPTACLE - 2P, 3W, 20A, 127V, NEMA 6-20R

PHOTOELECTRIC CONTROL FOR SITE LIGHTING

J J J

GFCI

IG

WP

DIMMER SWITCH, 1220mm AFF, 127VAC, 50 HZ RATED

THREE WAY TOGGLE SWITCH, 1220mm AFF, 127VAC RATED

AS INDICATED - SEE LIGHTING FIXTURE SCHEDULE

- SEE LIGHTING FIXTURE SCHEDULE

S

SD

Sa

ELECTRICAL SYMBOLS

LIGHTING FIXTURE WITH BUILT IN BATTERY PACK

NUMBER - INDICATES BRANCH CIRCUIT

(TYPICAL FOR ALL LIGHTING FIXTURES)

LOWER CASE - INDICATES CONTROLLING SWITCHES

SEE LIGHTING FIXTURE SCHEDULES

a 1

G

LIGHTING FIXTURE

SHUNT TRIP COIL

RACEWAY (2) - 4 mm2 + 4 mm2 GND IN 20 mm EMT UON

HANDHOLE, UNDERGROUND WITH LOCKABLE STEEL COVER (GROUND TEST WELL)

MANHOLE, UNDERGROUND WITH LOCKABLE STEEL COVER

TRANSFORMER - VOLTAGE, POWER, ISOLATION AND "K" RATINGS AS NOTED.

HOMERUN TO PANELBOARD. ARROWS INDICATE NUMBER OF CIRCUITS.

VOLTMETER

AMMETER

UNDERGROUND NEW WORK

HH

T

MH

CONDUIT TURNING UP

CONDUIT TURNING DOWN

OCCUPANCY SENSOR, WALL OR CEILING MOUNTED. AN 'H' SUBSCRIPT, IF

PRESENT, INDICATES AN OCCUPANCY SENSOR THAT IS CONFIGURED FOR A

HALLWAY; A '2' SUBSCRIPT, IF PRESENT INDICATES AN 2 CIRCUIT OCCUPANCY

SENSOR.

V

OS

NONFUSED DISCONNECT SWITCH

FLOOR MOUNTED (FLUSH OR STUBBED UP AS NOTED)

DUPLEX RECEPTACLE - 2P, 3W, 15A (AS NOTED), NEMA 6-20R, 127V,

FUSED DISCONNECT SWITCH

SINGLE PHASE ELECTRICAL MOTOR - INSIDE NUMERAL INDICATES HORSEPOWER

PANELBOARD, SURFACE OR RECESSED MOUNTED

MOTOR SWITCH, HORSEPOWER RATED, 127VAC - 1HP MIN

MS

F

- UNLESS OTHERWISE NOTED

- SECONDS

- POLYVINYL CHLORIDE

- SYMMETRICAL

- TELEPHONE TERMINAL BOARD

- WEATHER PROOF

- RIGID GALVANIZED STEEL

- RECEPTACLE

- TRANSFORMER

- VOLT AMPERES

LTG

- LIGHTING

- CIRCUIT

CKT

- VOLTAGE

V

- PHASE

- NOT TO SCALE

- NOT IN CONTRACT

- NATIONAL ELECTRICAL MANUFACTURER'S ASSOCIATION

- NON-FUSED SAFETY SWITCH

- MOUNTING HEIGHT

- MAIN LUGS ONLY

- MANHOLE

- MECHANICAL

- MAIN DISTRIBUTION PANEL

- MOTOR CIRCUIT PROTECTOR

- MAIN CIRCUIT BREAKER

- NATIONAL ELECTRICAL CODE

- FULL LOAD AMPERES

- FUSED OR FUSIBLE

- EXISTING TO REMAIN

- ELECTRICAL METALLIC TUBING

- CURRENT TRANSFORMER

- ELECTRIC/ ELECTRICAL

- FIRE ALARM CONTROL PANEL

- ELECTRIC WATER COOLER

ETR

FACP

FO

FLA

EX, EXIST

EWC

F

- FIBER OPTIC

- EXISTING

EF

EQUIP

ELEC

EMT

DWG

CT

CLG

- EXHAUST FAN

- EQUIPMENT

- DRAWING

- CEILING

NEC

NTS

Ø OR PH

NFSS

NIC

NEMA

MECH

MLO

MT HT

MH

MCP

MDP

MCB

XFMR

W

WP

VA

- WIRE

- THOUSAND CIRCULAR MILS

- JUNCTION BOX

- HAND-OFF-AUTOMATIC

- GROUND FAULT CIRCUIT INTERRUPTER

- GROUND WIRE

- KILOVAR HOUR

- GROUND

- KILOVOLT-AMPERES

- HERTZ

- HORSE POWER

- GOVERNMENT FURNISHED EQUIPMENT

ABBREVIATIONS

- CIRCUIT BREAKER

- AMPERE INTERRUPTING CAPACITY

- ABOVE FINISHED GRADE

- AIR HANDLING UNIT

- AMERICAN WIRE GAUGE

- AUTOMATIC TRANSFER SWITCH

- ABOVE FINISHED FLOOR

AHU

AWG

BLDG

C

CB

ASYM

ATS

AIC

- BUILDING

- CONDUIT

- ASYMMETRICAL

A

AFF

AFG

ACT

- AMPERES

- ACOUSTICS TILE

GW

JB

KVA

KVARH

KCMIL

HP

HZ

HOA

GFE

GND

GFCI

RGS

TEL

UON

TTB

TYP

SEC

RM

SYM

- TELEPHONE

- TYPICAL

- ROOM

P

PNL

PVC

RECPT

- POLE

- PANEL

CONTACT, NORMALLY OPEN

CONTACT, NORMALLY CLOSED

'L' COIL LATCHES AND 'R' COIL RESETS

RELAY, LATCHING TYPE

PANEL LAMP, LARGE, NEON, COLOR AS NOTED

WHEN COIL IS ENERGIZED

RELAY, MOMENTARY TYPE, NORMALLY CLOSED CONTACTS OPEN ONLY

TIME IS REACHED THE CONTACTS CLOSE AND REMAIN CLOSED UNTIL THE COIL IS DE-ENERGIZED

RELAY, ON DELAY TYPE, WHEN COIL IS ENERGIZED, AN ADJUSTABLE TIMER STARTS. WHEN THE SET

RELAY, ONE SHOT TYPE. CONTROL VOLTAGE IS CONSTANTLY APPLIED. WHEN AN EXTERNAL

DRY CONTACT IS CLOSED, THE RELAY INTERNAL CONTACTS CLOSE AND A TIMER STARTS. WHEN

THE SET TIME IS REACHED THE CONTACTS OPEN REGARDLESS OF THE STATUS OF THE EXTERNAL

DRY CONTACT

SHUNT CLOSE COIL

H

VOLTAGE REGULATOR, TYPE AND RATINGS AS NOTED

V

R

GENERATOR, SIZE AND RATINGS AS NOTED

G

SURGE SUPPRESSOR/LIGHTNING ARRESTER

CURRENT TRANSFORMER

POTENTIAL TRANSFORMER

MOLDED CASE CIRCUIT BREAKER

INSULATED CASE, POWER TYPE CIRCUIT BREAKER

G

I

S

L INSULATED CASE, POWER TYPE CIRCUIT BREAKER WITH SOLID STATE TRIP UNIT

'L'- LONG TIME 'S'- SHORT TIME 'I'- INSTANTANEOUS 'G'- GROUND FAULT

MEDIUM VOLTAGE FUSED SWITCH

UNDER VOLTAGE RELAY

OVER FREQUENCY RELAY

PHASE LOSS RELAY

DRIVEN GROUND ROD, COPPER CLAD, 3048 mm X 19 mm

MTS

- MANUAL TRANSFER SWITCH

- POTENTIAL TRANSFORMER

PT

AIR TERMINAL

GROUND CONNECTION

CR

- CONTROL RELAY

TIME CLOCK

CONTROL RELAY, MOMENTARY, WITH ONE NORMALLY

OPEN AND ONE NORMALLY CLOSED CONTACT

THREE PHASE ELECTRICAL MOTOR - INSIDE NUMERAL INDICATES HORSEPOWER

M

METER, DIGITAL WITH KWH, KVARH, KW, KVAR, KVA, KVAH, PF

AND PEAK KVA AND KVAR MEASUREMENTS

- KILOWATT

KW

- KILOWATT HOUR

KWH

- POWER FACTORPF

QUADRUPLEX RECEPTACLE - 2P, 3W, 127V, NEMA 6-20R, 380 mm AFF UON

UNDERGROUND BARE COPPER GROUND CONDUCTOR, SIZE AS NOTEDG

OVER VOLTAGE RELAY

UNDER FREQUENCY RELAY

PHASE REVERSAL/REVERSE PHASE ROTATION RELAY

- COPPER

CU

- HANDHOLEHH

- KILOVOLT AMP REACTIVEKVAR

- FUSED SAFETY SWITCHFSS

- WITH

W/

TELECOMMUNICATIONS SYMBOLS

FLOOR SLEEVES

CONDUIT IN WALL OR CEILING

CABLE TRAY SIZE AND TYPE PER DRAWINGS. SOLID LINE

INDICATES LOCATION ABOVE CEILING; DASHED LINE

INDICATES LOCATION BELOW FLOOR.

GROUNDING BUS BAR

19mm FIRE TREATED PLYWOOD

TV OUTLET AT 380 mm A.F.F.

AUDIOVISUAL OUTLET AT 380 mm A.F.F. UON

NIGHT BELL AT 150mm BELOW FINISHED CEILING (GFE).

RECESSED VOICE OUTLET AT 380 mm A.F.F. UON

- SHUNT CLOSE

SC

- SHUNT TRIP

ST

- MINUTES

MIN

TR - TELEPHONE ROOM

ENCLOSED CIRCUIT BREAKER

PROVIDE STANDARD RJ-45 JACK.

GFGI - GOVERNMENT FURNISHED GOVERNMENT INSTALLED

CEILING FAN WITH LIGHT KIT

J WALL MOUNTED JUNCTION BOX

OVERHEAD/DOWNLIGHT (SEE LIGHTING FIXTURE SCHEDULE FOR DETAILS)

GRID TYPE (SEE LIGHTING FIXTURE SCHEDULE FOR DETAILS)

COMBINATION STARTER WITH ADJUSTABLE, MAGNETIC TRIP ONLY, CIRCUIT

BREAKER DISCONNECT AND ADJUSTABLE, SOLID STATE, OVERLOAD RELAY

CFCI

- CONTRACTOR FURNISHED

CONTRACTOR INSTALLED

- CONTRACTOR FURNISHED

GOVERNMENT INSTALLED

CFGI

OR GOVERNMENT FURNISHED CONTRACTOR INSTALLED

1 NUMERAL INDICATES NEMA SIZE

RECESSED VOICE OUTLET AT 1220 mm A.F.F. UON

V

MINIMUM AREA = 0.3 m

WP

WP - WEATHERPROOF

MOV

- METAL OXIDE VARISTOR

- UNITED STATES GOVERNMENTUSG

TIME DELAY RELAY

WALL MOUNTED PUSH BUTTON FOR AUTOMATIC DOOR OPERATOR

STANDARD VOICE AND DATA OUTLET @ 380 mm AFF UON.

FLOOR MOUNTED VOICE & DATA OUTLET

WP

OUTLET PHONE IN WEATHER PROOF BOX

MINIMUM OF 90-MINUTE BACK-UP

M

L

R

OD

OS

1 2

3 4

TC

CR

ST

SC

A

2-1/2

6 155

3 78

1-1/2

1/2

3/4

(inches)

TRADE SIZE

METRIC SIZE

(mm)

CONDUIT

CONVERSION TABLE

METRIC/ENGLISH EQUIVALENT

1-1/4

3-1/2

OS

PH

CEILING MOUNTED PHOTOSENSOR

6 BUTTON CONTROL KEYPAD WITH ETCHED NAMEPLATE

SCS

P P

POWER SERVICE FITTING (FLOOR/WALL) MOUNTED FOR CONNECTION TO

FURNITURE SYSTEM AS SPECIFIED.

D D

JUNCTION BOX FLOOR OR WALL MOUNTED FOR

CONNECTION TO FURNITURE SYSTEM.

FBX

FLOOR BOX ("X" DENOTES TYPE AS SPECIFIED: "P" INDICATES POKE-THRU, "F" INDICATES FLUSH)

DUPLEX RECEPTACLE - 2P, 3W, 127V, NEMA 6-20R, 1219mm AFF UON, D-DEDICATED CIRCUIT

PB PULL BOX

XX SPECIAL PURPOSE RECEPTACLE. TYPE AS INDICATED ON DRAWINGS.

COORDINATE RECEPTACLE TYPE WITH ACTUAL EQUIPMENT PRIOR TO INSTALLATION.

3-POSITION WALL SWITCH FOR MOTORIZED PROJECTION SCREEN

PS

S

IC CONSULAR TELLER WINDOW INTERCOM

WD WD TELLER FINGERPRINT STATION AND JUNCTION BOX

CK

MICROPHONE AND KEYPAD FOR TELLER WINDOW

X

CEILING MOUNTED

DUPLEX RECEPTACLE - 2P, 3W, 15A (AS NOTED), NEMA 6-20R, 127V,

CEILING MOUNTED VOICE & DATA OUTLET

P/D POWER AND DATA POLE FEEDING SYSTEMS FURNITURE

FPP

FIBER PATCH PANEL

CPP

COPPER PATCH PANEL

BSW

BACKBONE SWITCH

CSW

COPPER SWITCH

RECLOSING RELAY

171615

P

O

N

M

L

171615

P

O

N

M

L

K

J

I

1 2 3 4 5 6 7 8 9 10 11 12 13 14

H

G

F

E

D

C

B

A

1413121110987654321

A

B

C

D

E

F

G

H

I

J

K

SMITHGROUPJJR, INC.

901 K STREET NW

SUITE 400

WASHINGTON, DC 20001

T 202.842.2100 F 202.974.4500 www.smithgroup.com

CADD Plot ScaleCADD File Name

Classification

Project Number

OBO Project Number PhaseDrawing Scale

Drawing Title

United States Department of State

Washington, D.C.

Revisions

Date

Drawn By

Checked By

Sheet Number

OFFICE OF OVERSEAS BUILDINGS OPERATIONS

SAO PAULO, BRAZIL

Reviewed for Code Compliance:

OBO/PE/DE

FINALCDDDRFP

U.S. CONSULATE GENERAL

for

26915.000

CONSULAR RENOVATIONS

This document is the property of the U.S. Government. Further prohibited without the express written approval of:

reproduction and/or distribution outside the contractor team is

U.S. Department of State

Washington, D.C. 20520

ATTN: Brian Mulcahy

WARNING:

COB

13 JAN 2012

XJ-0K-T003

NONE

MK

TF

ELECTRICAL SYMBOLS

E001

UNCLASSIFIED

UNCLASSIFIED

UNCLASSIFIED

GRUG-E001.dwg

ICIC

CKWD

ICIC

CKWD

ICIC

CKWD

ICIC

CKWD

ICIC

CKWD

ICIC

CKWD

ICIC

CKWD

ICIC

CKWD

ICIC

CKWD

ICIC

CKWD

ICIC

CKWD

ICIC

CKWD

ICIC

CKWD

ICIC

CKWD

ICIC

CKWD

ICIC

CKWD

ICIC

CKWD

ICIC

CKWD

ICIC

CKWD

ICIC

CKWD

ICIC

CKWD

ICIC

CKWD

ICCK

WD IC

ICCK

WD IC

ICCK

WD IC

21042184

2184H

2184J

21322133

A

B

C

D

E

F

G

12 1234567891011

CONSULAR CHIEF

NIV CHIEF

GENERAL WORK

AREA

ARSO

CONSULAR

DEPUTIES

CONF / TRAINING

CONSULAR

DEPUTIES

PRIVACY

PRIVACY

EXISTING

TELECOM

EXISTING

ELECTRICAL

EXISTING KITCHEN

EXISTING PBX

EXISTING MAIN

TERMINAL SPACE

EXISTING

MECHANICAL

OPEN OFFICE

OPEN OFFICE

RECEPTION

ET101---

E401

ET101---

EXISTING 610MM

BASKET CABLE TRAY

TO REMAIN

TYP.

E

E

E

E

E

E

E

E

E

E

E

E

E

E

E

E

E

E

E

E

E

E

E

E

E

E

E

E

E

E

E

E

E

E

E

E

E

E

E

E

E

E

E

E

E

E

E

E

E

E

E

E

E

E

E

E

E

E

E

E

E

E

E

E

E

E

E

E

E

E

E

E

EXISTING 305MM

BASKET CABLE TRAY

TO REMAIN

EXISTING 305MM

BASKET CABLE TRAY

TO REMAIN

EXISTING 305MM

BASKET CABLE TRAY

TO REMAIN

EXISTING 610MM

BASKET CABLE TRAY

TO REMAIN

EXISTING 305MM

BASKET CABLE TRAY

TO REMAIN

E401

TYP.

300mm X

300mm J-BOX

171615

P

O

N

M

L

171615

P

O

N

M

L

K

J

I

1 2 3 4 5 6 7 8 9 10 11 12 13 14

H

G

F

E

D

C

B

A

1413121110987654321

A

B

C

D

E

F

G

H

I

J

K

SMITHGROUPJJR, INC.

901 K STREET NW

SUITE 400

WASHINGTON, DC 20001

T 202.842.2100 F 202.974.4500 www.smithgroup.com

CADD Plot ScaleCADD File Name

Classification

Project Number

OBO Project Number PhaseDrawing Scale

Drawing Title

United States Department of State

Washington, D.C.

Revisions

Date

Drawn By

Checked By

Sheet Number

OFFICE OF OVERSEAS BUILDINGS OPERATIONS

SAO PAULO, BRAZIL

Reviewed for Code Compliance:

OBO/PE/DE

FINALCDDDRFP

U.S. CONSULATE GENERAL

for

26915.000

CONSULAR RENOVATIONS

0 2000 5000 10000

1:100

This document is the property of the U.S. Government. Further prohibited without the express written approval of:

reproduction and/or distribution outside the contractor team is

U.S. Department of State

Washington, D.C. 20520

ATTN: Brian Mulcahy

WARNING:

COB

13 JAN 2012

XJ-0K-T003

1 : 100

MK

TF

CONSULATE INTERCOM/QUEUING

SYSTEM PLAN

ET101

SENSITIVE BUT UNCLASSIFIED

SENSITIVE BUT UNCLASSIFIED

SENSITIVE BUT UNCLASSIFIED

A. INTENT OF THE DRAWINGS - THE DRAWINGS ARE DIAGRAMMATIC

AND SHOW THE GENERAL LOCATION OF OUTLETS, RACEWAYS, AND

EQUIPMENT. THE DRAWINGS DO NOT SHOW ALL NECESSARY

OFFSETS, JUNCTION BOXES, CABLETRAY TRANSITIONS, AND

ADJUSTMENTS NECESSITATED BY COORDINATION WITH OTHER

TRADES. THE COST OF ALL OFFSETS, RACEWAY COMPONENTS,

ACCESSORIES, AND ADJUSTMENTS NECESSITATED BY

COORDINATION WITH OTHER TRADES SHALL BE INCLUDED IN THE

CONTRACTOR'S BID.

B. COORDINATION WITH OTHER TRADES - EXAMINE AND REVIEW THE

CONTRACT DOCUMENTS OF ALL DIVISIONS IN ORDER TO

COORDINATE THE INSTALLATION OF WORK. USE DIMENSIONED

ARCHITECTURAL AND STRUCTURAL CONTRACT DRAWINGS TO VERIFY

THE SPACE NECESSARY FOR LOCATING OUTLETS, RACEWAYS, AND

EQUIPMENT. USE FIELD MEASUREMENTS TO VERIFY DIMENSIONS

WHERE AREAS ARE CONGESTED, AND EXACT LOCATION IS CRITICAL

TO ASSURE PROPER INSTALLATION. COORDINATION SHALL INCLUDE,

BUT SHALL NOT BE LIMITED TO, VERIFYING THE LOCATION AND SIZE

OF OPENINGS PENETRATIONS IN FLOORS, WALLS, PARTITIONS,

CEILINGS, AND ROOFS WITH THE INSTALLING TRADES; ALLOCATION

OF SPACE WITH OTHER TRADES INSTALLING WORK IN CHASES,

SHAFTS, CEILING INTERSTITIAL SPACES, AND EQUIPMENT SPACES;

AND THE PHASING OF INSTALLATION WORK WITH THAT OF OTHER

TRADES.

C. WORKMANSHIP - INSTALL ALL WORK IN A WORKMANLIKE MANNER

THAT PROVIDES A FIRST CLASS COMPLETED INSTALLATION. MOVE,

CORRECT, AND REPLACE ANY WORK DEEMED UNACCEPTABLE AT

THE DISCRESION OF THE ARCHITECT /ENGINEER.

D. EQUIPMENT - INSTALL ALL EQUIPMENT IN ACCORDANCE WITH THE

MANUFACTURER'S PRINTED INSTALLATION INSTRUCTIONS, THE

SPECIFICATIONS, AND APPROVED SHOP DRAWINGS. PROVIDE

SERVICE AND OPERATING CLEARANCES AROUND ALL SIDES OF

EACH PIECE OF EQUIPMENT IN ACCORDANCE WITH REGULATORY

REQUIREMENTS, MANUFACTURER'S PRINTED REQUIREMENTS AND

RECOMMENDATIONS.

E. SEE DETAILS 3 AND 4 ON SHEET ET502 FOR BALLISTIC RESISTANT

CONDUIT PENETRATIONS AT ALL FEBR WALLS.

F. ALL DEVICES WITH AN "E" SUBSCRIPT ARE EXISTING TO REMAIN.

MAINTAIN ALL WIRING AND CIRCUIT CONTINUITY DURING

CONSTRUCTION.

1 : 100

ET101

CONSULATE INTERCOM/QUEUING SYSTEM PLAN

SHEET NOTES

KEYNOTES

E401 PROVIDE CONSULAR SECTION INTERCOM AND QUEUING SYSTEM

DEVICES AT NEW WINDOWS. COORDINATE AND CONNECT TO

EXISTING QUEUING AND INTERCOM SYSTEM FROM EXISTING TO

REMAIN WINDOWS TO NEW WINDOWS. MATCH EXISTING SYSTEM

AND MEET SED 2011 REQUIREMENTS FOR IC SYSTEM. ALL

CONDUIT PENETRATIONS SHALL MEET FEBR REQUIREMENTS SEE

DETAILS ON SHEET ET501.

Amendment 01 24 February, 2012

GRUG-ET101.dwg

= QUEUING SYSTEM WIRE

= CABLE TRAY

21042184

2184H

2184J

21322133

A

B

C

D

E

F

G

12 1234567891011

102B

102A

A

B

B

B B

B

B

A

D

A

A201

A101---

A201

A

CONSULAR CHIEF

NIV CHIEF

GENERAL WORK

AREA

ARSO

CONSULAR

DEPUTIES

CONF / TRAINING

CONSULAR

DEPUTIES

PRIVACY

PRIVACY

EXISTING

TELECOM

EXISTING

ELECTRICAL

EXISTING KITCHEN

EXISTING PBX

EXISTING MAIN

TERMINAL SPACE

EXISTING

MECHANICAL

OPEN OFFICE

OPEN OFFICE

RECEPTION

0A3A

0A3A

0A3A

0A3B

0A3A

0A3A

TYP

0B3A

A

A201

A201

A101A401

A101A401

A101A401

A101A401

0A3B

A101A401

A101A401

A2

A201

A202

A6

A10

D

119A

FRAUD

PREVENTION

EXISTING

KITCHEN

A202

A202

C

A202

EXISTING

TELECOM

EXISTING EMR

EXISTING

STORAGE

EXISTING

CORRIDOR

104A

A

0A3B

A15

A15A15 A15 A15 8 A101A401

A101A501

A24 A24 A21

A23

A22

A20

A20

A20

A22

A24

A21

A101A401

TYP

EXISTING

ELECTICAL ROOM

TYP

A30

TYP

A30

A

A

A

A

WAITING ROOM

GENERAL WORK

AREA

A32

A31A31

A202

A

D

A2

0A3B

A

A30

A34

A33

A34A34

TYP

A34

EXISTING WALL / DOOR / WINDOW

TO REMAIN

EXISTING WALL / DOOR / WINDOW

TO BE DEMOLISHED

NEW CONSTRUCTION

NOT IN SCOPE

171615

P

O

N

M

L

171615

P

O

N

M

L

K

J

I

1 2 3 4 5 6 7 8 9 10 11 12 13 14

H

G

F

E

D

C

B

A

1413121110987654321

A

B

C

D

E

F

G

H

I

J

K

SMITHGROUPJJR, INC.

901 K STREET NW

SUITE 400

WASHINGTON, DC 20001

T 202.842.2100 F 202.974.4500 www.smithgroup.com

CADD Plot ScaleCADD File Name

Classification

Project Number

OBO Project Number PhaseDrawing Scale

Drawing Title

United States Department of State

Washington, D.C.

Revisions

Date

Drawn By

Checked By

Sheet Number

OFFICE OF OVERSEAS BUILDINGS OPERATIONS

SAO PAULO, BRAZIL

Reviewed for Code Compliance:

OBO/PE/DE

FINALCDDDRFP

U.S. CONSULATE GENERAL

for

26915.000

CONSULAR RENOVATIONS

0 2000 5000 10000

1:100

This document is the property of the U.S. Government. Further prohibited without the express written approval of:

reproduction and/or distribution outside the contractor team is

U.S. Department of State

Washington, D.C. 20520

ATTN: Brian Mulcahy

WARNING:

COB

13 JAN 2012

XJ-0K-T003

1 : 100

DAD

CJM

FIRST FLOOR PLAN

A101

SENSITIVE BUT UNCLASSIFIED

SENSITIVE BUT UNCLASSIFIED

SENSITIVE BUT UNCLASSIFIED

1 : 100

A101

NEW CONSTRUCTION - FIRST FLOOR

1. DOORS WITH TAGS ARE ENTIRELY NEW. REFER TO DOOR

SCHEDULE FOR MORE INFORMATION. DOORS WITHOUT TAGS

ARE EXISTING TO REMAIN.

2. SEE COB A601 FOR SCHEDULES.

3. SEE COB A102 FOR REFLECTED CEILING PLAN.

4. REFER TO COB Q SERIES DRAWINGS FOR EQUIPMENT PLANS.

SHEET NOTES

KEYNOTES

GRAPHIC LEGEND

A2 REPLACE PORTION OF WALL WITH CONSTRUCTION MATCHING

EXISTING.

A6 EXISTING UNDER FLOOR MANHOLE ACCESS TO DRAINAGE SYSTEM.

A10 WORK IN THIS AREA LIMITED TO NEW WORKSTATIONS AND THEIR

SUPPORT.

A15 NEW COUNTERTOP/WORKSURFACE

A20 PROVIDE NEW TRANSITION STRIP AT DOOR PER DETAIL 5A/A601,

CARPET TO CARPET.

A21 PROVIDE NEW THRESHOLD AT DOOR PER DETAIL 5B/A601, CARPET

TO CONCRETE AT FIRE RATED DOOR.

A22 PROVIDE NEW TRANSITION STRIP AT DOOR PER DETAIL 5C/A601,

CARPET TO RESILIENT TILE.

A23 PROVIDE NEW THRESHOLD AT DOOR PER DETAIL 5D/A601, CARPET

TO CONCRETE, EXTERIOR.

A24 PROVIDE NEW THRESHOLD STRIP AT DOOR PER DETAIL 5E/A601,

CARPET TO CONCRETE, INTERIOR.

A30 NEW 15MIN FE/BR HARDLINE WALL - REF SHEET LS101 FOR DETAILS

A31 NEW PRIVACY WALL AT ALL EXISTING WINDOWS. SEE DETAIL 3/A301.

A32 NEW ACOUSTIC TREATMENT AT ALL EXISTING PRIVACY PANELS.

A33 NEW EXTERIOR WALL [CP1], DRAINAGE PANEL [DP1], AIR BARRIER

[AB1], ON 20MM EXTERIOR GRADE PLYWOOD AND METAL FRAMING -

REFERENCE DETAIL 9/A601 (SIM).

A34 EXISTING FURNITURE, RELOCATED. REFER TO SHEET Q101 FOR

ADDITIONAL INFORMATION.

Amendment 01 24 February, 2012 CCD-01 10 October, 2012

GRUG-A101.dwg

AutoCAD SHX Text

BIX BLOCK BY POST

AutoCAD SHX Text

CABLE RUN IN EXISTING CABLE TRAY

AutoCAD SHX Text

BIX BLOCK BY POST

ICIC

CKWD

ICIC

CKWD

ICIC

CKWD

ICIC

CKWD

ICIC

CKWD

ICIC

CKWD

ICIC

CKWD

ICIC

CKWD

ICIC

CKWD

ICIC

CKWD

ICIC

CKWD

ICIC

CKWD

ICIC

CKWD

ICIC

CKWD

ICIC

CKWD

ICIC

CKWD

ICIC

CKWD

ICIC

CKWD

ICIC

CKWD

ICIC

CKWD

ICIC

CKWD

ICIC

CKWD

ICCK

WD IC

ICCK

WD IC

ICCK

WD IC

21042184

2184H

2184J

21322133

A

B

C

D

E

F

G

12 1234567891011

CONSULAR CHIEF

NIV CHIEF

GENERAL WORK

AREA

ARSO

CONSULAR

DEPUTIES

CONF / TRAINING

CONSULAR

DEPUTIES

PRIVACY

PRIVACY

EXISTING

TELECOM

EXISTING

ELECTRICAL

EXISTING KITCHEN

EXISTING PBX

EXISTING MAIN

TERMINAL SPACE

EXISTING

MECHANICAL

OPEN OFFICE

OPEN OFFICE

RECEPTION

ET101---

E401

ET101---

EXISTING 610MM

BASKET CABLE TRAY

TO REMAIN

TYP.

E

E

E

E

E

E

E

E

E

E

E

E

E

E

E

E

E

E

E

E

E

E

E

E

E

E

E

E

E

E

E

E

E

E

E

E

E

E

E

E

E

E

E

E

E

E

E

E

E

E

E

E

E

E

E

E

E

E

E

E

E

E

E

E

E

E

E

E

E

E

E

E

EXISTING 305MM

BASKET CABLE TRAY

TO REMAIN

EXISTING 305MM

BASKET CABLE TRAY

TO REMAIN

EXISTING 305MM

BASKET CABLE TRAY

TO REMAIN

EXISTING 610MM

BASKET CABLE TRAY

TO REMAIN

EXISTING 305MM

BASKET CABLE TRAY

TO REMAIN

E401

TYP.

300mm X

300mm J-BOX

171615

P

O

N

M

L

171615

P

O

N

M

L

K

J

I

1 2 3 4 5 6 7 8 9 10 11 12 13 14

H

G

F

E

D

C

B

A

1413121110987654321

A

B

C

D

E

F

G

H

I

J

K

SMITHGROUPJJR, INC.

901 K STREET NW

SUITE 400

WASHINGTON, DC 20001

T 202.842.2100 F 202.974.4500 www.smithgroup.com

CADD Plot ScaleCADD File Name

Classification

Project Number

OBO Project Number PhaseDrawing Scale

Drawing Title

United States Department of State

Washington, D.C.

Revisions

Date

Drawn By

Checked By

Sheet Number

OFFICE OF OVERSEAS BUILDINGS OPERATIONS

SAO PAULO, BRAZIL

Reviewed for Code Compliance:

OBO/PE/DE

FINALCDDDRFP

U.S. CONSULATE GENERAL

for

26915.000

CONSULAR RENOVATIONS

0 2000 5000 10000

1:100

This document is the property of the U.S. Government. Further prohibited without the express written approval of:

reproduction and/or distribution outside the contractor team is

U.S. Department of State

Washington, D.C. 20520

ATTN: Brian Mulcahy

WARNING:

COB

13 JAN 2012

XJ-0K-T003

1 : 100

MK

TF

CONSULATE INTERCOM/QUEUING

SYSTEM PLAN

ET101

SENSITIVE BUT UNCLASSIFIED

SENSITIVE BUT UNCLASSIFIED

SENSITIVE BUT UNCLASSIFIED

A. INTENT OF THE DRAWINGS - THE DRAWINGS ARE DIAGRAMMATIC

AND SHOW THE GENERAL LOCATION OF OUTLETS, RACEWAYS, AND

EQUIPMENT. THE DRAWINGS DO NOT SHOW ALL NECESSARY

OFFSETS, JUNCTION BOXES, CABLETRAY TRANSITIONS, AND

ADJUSTMENTS NECESSITATED BY COORDINATION WITH OTHER

TRADES. THE COST OF ALL OFFSETS, RACEWAY COMPONENTS,

ACCESSORIES, AND ADJUSTMENTS NECESSITATED BY

COORDINATION WITH OTHER TRADES SHALL BE INCLUDED IN THE

CONTRACTOR'S BID.

B. COORDINATION WITH OTHER TRADES - EXAMINE AND REVIEW THE

CONTRACT DOCUMENTS OF ALL DIVISIONS IN ORDER TO

COORDINATE THE INSTALLATION OF WORK. USE DIMENSIONED

ARCHITECTURAL AND STRUCTURAL CONTRACT DRAWINGS TO VERIFY

THE SPACE NECESSARY FOR LOCATING OUTLETS, RACEWAYS, AND

EQUIPMENT. USE FIELD MEASUREMENTS TO VERIFY DIMENSIONS

WHERE AREAS ARE CONGESTED, AND EXACT LOCATION IS CRITICAL

TO ASSURE PROPER INSTALLATION. COORDINATION SHALL INCLUDE,

BUT SHALL NOT BE LIMITED TO, VERIFYING THE LOCATION AND SIZE

OF OPENINGS PENETRATIONS IN FLOORS, WALLS, PARTITIONS,

CEILINGS, AND ROOFS WITH THE INSTALLING TRADES; ALLOCATION

OF SPACE WITH OTHER TRADES INSTALLING WORK IN CHASES,

SHAFTS, CEILING INTERSTITIAL SPACES, AND EQUIPMENT SPACES;

AND THE PHASING OF INSTALLATION WORK WITH THAT OF OTHER

TRADES.

C. WORKMANSHIP - INSTALL ALL WORK IN A WORKMANLIKE MANNER

THAT PROVIDES A FIRST CLASS COMPLETED INSTALLATION. MOVE,

CORRECT, AND REPLACE ANY WORK DEEMED UNACCEPTABLE AT

THE DISCRESION OF THE ARCHITECT /ENGINEER.

D. EQUIPMENT - INSTALL ALL EQUIPMENT IN ACCORDANCE WITH THE

MANUFACTURER'S PRINTED INSTALLATION INSTRUCTIONS, THE

SPECIFICATIONS, AND APPROVED SHOP DRAWINGS. PROVIDE

SERVICE AND OPERATING CLEARANCES AROUND ALL SIDES OF

EACH PIECE OF EQUIPMENT IN ACCORDANCE WITH REGULATORY

REQUIREMENTS, MANUFACTURER'S PRINTED REQUIREMENTS AND

RECOMMENDATIONS.

E. SEE DETAILS 3 AND 4 ON SHEET ET502 FOR BALLISTIC RESISTANT

CONDUIT PENETRATIONS AT ALL FEBR WALLS.

F. ALL DEVICES WITH AN "E" SUBSCRIPT ARE EXISTING TO REMAIN.

MAINTAIN ALL WIRING AND CIRCUIT CONTINUITY DURING

CONSTRUCTION.

1 : 100

ET101

CONSULATE INTERCOM/QUEUING SYSTEM PLAN

SHEET NOTES

KEYNOTES

E401 PROVIDE CONSULAR SECTION INTERCOM AND QUEUING SYSTEM

DEVICES AT NEW WINDOWS. COORDINATE AND CONNECT TO

EXISTING QUEUING AND INTERCOM SYSTEM FROM EXISTING TO

REMAIN WINDOWS TO NEW WINDOWS. MATCH EXISTING SYSTEM

AND MEET SED 2011 REQUIREMENTS FOR IC SYSTEM. ALL

CONDUIT PENETRATIONS SHALL MEET FEBR REQUIREMENTS SEE

DETAILS ON SHEET ET501.

Amendment 01 24 February, 2012

GRUG-ET101.dwg

= QUEUING SYSTEM WIRE

= CABLE TRAY

UTP CABLE

4 PAIRS CAT-6

4 PAIRS CAT-6

RJ-45 TYPE JACK FOR

FOR SPARE

RJ-45 TYPE JACK FOR VOICE

RJ-45 TYPE JACK FOR SPARE

SPARE CA WINDOW ONLY

FOR VOICE

4 PAIRS CAT-6

4 PAIRS CAT-6

RJ-45 TYPE JACK FOR DATA

SINGLE GANG FACEPLATE

NEW CABLE TRAY

MIN 35 mm CONDUIT FROM

WORKSTATION WALL OUTLET

SPARE CABLE STATE LAN CABLE VOICE CABLE

SECTION SECTION SECTION

BUSHING

SPARE CABLE

SECTION

MIN 41 mm CONDUIT FROM

WORKSTATION POKE-THRU

EXIST.

MTS

TERMINATION

FIBER

CABINET

LAN

SWITCH

CABINET

LAN EQUIPMENT

FIBER

SWITCH

TERMINATION

CABINET

LAN

EQUIPMENT CABINET

PATCH PANEL

WORKSTATION

TYPICAL

OUTLET

TR 110

FOFO FO FO

PROVIDE NEW MULTIMODE FIBER OPTIC CABLES

F/O F/0

PP PP

FO

PROVIDE NEW MULTIMODE FIBER OPTIC CABLES

TO LAN RACK

TYPE 1

CA WINDOW

TYPICAL

OUTLET

2 - CAT 6 CABLE

TYPE 2

1 - CAT 6 SPARE

2 - CAT 6 SPARE

2 - CAT 6 CABLE

EXIST.EXIST.

HORIZONTAL

BIX

BLOCK

TR 110

BIX

BLOCK

RISER

BLOCK

DISTRIBUTION

BIX

BLOCK

BIX

PANEL

PROTECTOR

PRIMARY

PANEL

PROTECTOR

PRIMARY

SWITCH

PBX

BLOCK

BIX

BLOCK

BIX

OUTLET

TYPICAL

WORKSTATION

RISER

MTS

PBX

NEW 100 PAIR CAT3

UTP RISER CABLE

CAT6

UTP CABLE

500 PAIR OSP CABLE

FROM CAMPUS DEMARC

SEE SITE RISER DIAGRAM

TO ANCILLARY BUILDINGS

ON SHEET ET5.05.

DASHED LINE INDICATES BY OTHERS

UCR

TSEF

PP

F/O

UTP CAT6 CABLES

(INTERNET) FROM WS

(1) 100-PR UTP CAT3

CABLES FROM PBX

4-PR UTP CAT6 CABLES (VOICE)

FROM WS

NEW NETWORK 48 PORT

NETWORK SWITCH TO MATCH

EXISTING.

NEW NETWORK 48 PORT PATCH

PANEL

NEW NETWORK 48 PORT

NETWORK SWITCH TO MATCH

EXISTING.

NEW NETWORK 48 PORT

NETWORK SWITCH TO MATCH

EXISTING.

NEW NETWORK 48 PORT PATCH

PANEL

NEW NETWORK 48 PORT PATCH

PANEL

PP1

PP2

PP3

PP4

PP5

PP6

PP7

PP8

PP9

PP10

PP11

TO MAIN TERMINAL SPACE

LEVEL 1

FPP

BSW

CSW

CPP

EXISTING CABLE

TRAY

TYPICAL

WORKSTATION

WALL OUTLET

35mm CONDUIT

LOCATE CONDUIT WITHIN

WALLS AND COLUMNS TO

NEAREST ACCESSIBLE CEILING

TYPICAL SYSTEMS

FURNITURE

POWER/DATA POLE

FEED

SYSTEMS

FURNITURE

WORKSTATION

NEW AS REQ'D

NEW AS REQ'D

NEW AS

REQ'D

NEW AS

REQ'D

NEW FIBER CABLE. PROVIDE

(1) 6-STRAND 62.5/125um MM

FIBER OPTIC WITH SC

TERMINATIONS TO MATCH

EXISTING

GROUND BAR

TELECOMMUNICATIONS

WORKSTATION

TERMINATION FIELD

HORIZONTAL CABLE

CAT 6 VOICE CABLE

TO WORKSTATION OUTLET

300 PAIR BIX

RISER CABLE

TERMINATION FIELD

300 PAIR BIX

PAINT TO MATCH WALLS.

EX PLYWOOD BACKBOARD.

PAINT WITH FIRE RETARDANT

102 mm SLEEVES

171615

P

O

N

M

L

171615

P

O

N

M

L

K

J

I

1 2 3 4 5 6 7 8 9 10 11 12 13 14

H

G

F

E

D

C

B

A

1413121110987654321

A

B

C

D

E

F

G

H

I

J

K

SMITHGROUPJJR, INC.

901 K STREET NW

SUITE 400

WASHINGTON, DC 20001

T 202.842.2100 F 202.974.4500 www.smithgroup.com

CADD Plot ScaleCADD File Name

Classification

Project Number

OBO Project Number PhaseDrawing Scale

Drawing Title

United States Department of State

Washington, D.C.

Revisions

Date

Drawn By

Checked By

Sheet Number

OFFICE OF OVERSEAS BUILDINGS OPERATIONS

SAO PAULO, BRAZIL

Reviewed for Code Compliance:

OBO/PE/DE

FINALCDDDRFP

U.S. CONSULATE GENERAL

for

26915.000

CONSULAR RENOVATIONS

This document is the property of the U.S. Government. Further prohibited without the express written approval of:

reproduction and/or distribution outside the contractor team is

U.S. Department of State

Washington, D.C. 20520

ATTN: Brian Mulcahy

WARNING:

COB

13 JAN 2012

XJ-0K-T003

As indicated

CS

TF

TELECOMMUNICATIONS DETAILS

ET501

UNCLASSIFIED

UNCLASSIFIED

UNCLASSIFIED

NONE

ET501

CABLE TRAY PATHWAY DETAIL

NONE

ET501

CONNECTIVITY DIAGRAM - LAN & SPARE

NONE

ET501

CONNECTIVITY DIAGRAM - VOICE

NONE

ET501

VOICE PUNCH DOWN DIAGRAM

NONE

ET501

RACK AND CROSS CONNECT DETAILS

NONE

ET501

TYPICAL DESK WORKSTATION OUTLET

NONE

ET501

DATA ONE-LINE DIAGRAM & WORKSTATIONS CABLE

PLAN

GRUG-ET501.dwg

Sheets and Views
Attachment A-18-A201
Attachment A-20-A301
Attachment A-21-A401
Attachment A-53-E001
Attachment A-58.1-ET101_10445
Attachment A-58.2-ET101A_16760
Attachment A-61.1-ET501A_16743
Attachment A-61.2-ET501B_16760

File details come from the government source that posted it. Updated .