4 - Drawings REV F-001.pdf

PDF 982 KB Posted

Attached to
Fire Alarm Replacement at FCC Coleman Federal contract opportunity
Solicitation number
15B30221B00000001
Issued by
Department of Justice Bureau of Prisons Field Acquisition Office

About this file

This document includes a federal contract opportunity solicitation and related file. The solicitation is for a firm-fixed-price construction contract valued between $1 million to $5 million to remove an existing fire alarm system and install a new one at the Federal Correctional Complex in Coleman, Florida. The performance period is 365 calendar days from notice to proceed. Interested vendors must be registered as a small business in SAM.gov under NAICS code 238210 with a $16.5 million size standard. The solicitation and any amendments will be distributed solely through SAM.gov. The related file provides drawings and notes for the fire alarm replacement, including project scope, demolition requirements, new equipment to be installed, and other technical details.

View the file

Other files for this federal contract opportunity

Other files attached to Fire Alarm Replacement at FCC Coleman, newest first.
File Type Posted
Bid Abstract.pdf PDF
AMEND 0007 COL.pdf PDF
AMEND 0006 COL.pdf PDF
5 - Construction Wage Rate 9242021.pdf PDF
AMEND 0005 COL.pdf PDF
AMEND 0004 COL.pdf PDF
Site Visit Meeting Minutes.pdf PDF
Questions and Answers FCC Coleman.pdf PDF
AMEND 0003 COL.pdf PDF
5 - Construction Wage Rate 7092021.pdf PDF
AMEND 0002 COL.pdf PDF
AMEND 0001 COL.pdf PDF
2 - Solicitation.pdf PDF
4 - Drawings.pdf PDF
3 - Specification.pdf PDF
1 - Instructions to Bidders.pdf PDF
7 - Criminal History Check Form.pdf PDF
6 - SF24 Bid Bond.pdf PDF
5 - Construction Wage Rate.pdf PDF
Show all 19

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

DESIGN AND INSTALLATION SHALL BE IN ACCORDANCE WITH FBOP

ADOPTED CODES AND STARDNARDS AND THE FOLLOWING: NFPA 70,

"NATIONAL ELECTRIC CODE", 2020 EDITION; NFPA 70, "NATIONAL

ELECTRICAL CODE", 2020 EDITION; NFPA 101, "LIFE SAFETY CODE"' 2018

EDITION; NFPA 241, "SAFEGUARDING CONSTRUCTION, ALTERATION, AND

DEMOLITION OPERATIONS" 2019 EDITION, INTERNATIONAL BUILDING

CODE, 2018 EDITION.

CONTRACTOR SHALL VISIT JOB SITE PRIOR TO BID WITH THE PROJECT

DOCUMENTS AND SPECIFICATIONS TO BECOME FAMILIAR WITH THE

SITE AND SCOPE OF WORK. NOTIFY CONTRACTING OFFICER'S

REPRESENTATIVE WITH ANY DISCREPANCIES OUTSIDE THIS DESIGN

INTENT. ANY CHANGE ORDER REQUEST AS A RESULT OF

COORDINATION BETWEEN TRADES SHALL BE DENIED.

ADHERE TO AND OBTAIN ALL PERMITS, LICENSES, FOR BOTH LOCAL

AND FEDERAL GOVERNMENT REQUIREMENTS.

DO NOT SCALE PLANS FOR THE PURPOSE OF ESTABLISHING

DIMENSIONS. FIELD DIMENSION GOVERN.

FIRE STOP ALL PENETRATIONS OF SMOKE/FIRE PARTITIONS. FIRE

STOPPING SHALL BE OF UL LISTED ASSEMBLY.

IF ASBESTOS OR LEAD BASED PAINT IS FOUND, SUB-CONTRACTOR

IMMEDIATELY STOP WORK AND NOTIFY OWNER. OWNER IS

RESPONSIBLE FOR ABATEMENT OF LEAD BASED PAINT AND ASBESTOS.

1.

2.

3.

4.

5.

6.

GENERAL NOTES

UNLESS OTHERWISE NOTED, DEMOLISH EXISTING FIRE DETECTION, FIRE

ALARM, AND OCCUPANT NOTIFICATION SYSTEM IN ITS ENTIRETY INSIDE

THE INDICATED PROJECT SCOPE AREA UNLESS OTHERWISE NOTED.

CONTRACTOR SHALL REPAIR IN KIND ANY DAMAGES THE BUILDING

SUSTAINS DURING DEMOLITION.

CONTRACTOR SHALL DISPOSE OF ALL DEMOLISHED COMPONENTS AND

MATERIALS IN ACCORDANCE WITH ALL LOCAL AND FEDERAL

REGULATIONS.

EXISTING FIRE ALARM AND OCCUPANT NOTIFICATION SYSTEM IS TO

REMAIN IN OPERATION AT ALL TIMES TO THE FULLEST EXTENT POSSIBLE,

UNTIL NEW FIRE ALARM DEVICES ARE INSTALLED AND TESTED. PLANNED

SYSTEM IMPAIRMENTS SHALL COMPLY WITH NFPA 72 REQUIREMENTS. A

FIRE WATCH WILL BE PROVIDED FOR SYSTEM IMPAIRMENTS AT THE

DISCRETION OF THE SITE/ FACILITY AHJ.

MAINTAIN THE EXISTING FIRE ALARM EQUIPMENT FULLY OPERATIONAL

UNTIL THE NEW EQUIPMENT HAS BEEN TESTED AND ACCEPTED BY THE

CONTRACTING OFFICER'S REPRESENTATIVE (COR). AS NEW EQUIPMENT IS

INSTALLED, LABEL IT "NOT IN SERVICE" UNTIL THE NEW EQUIPMENT IS

ACCEPTED. ONCE THE NEW SYSTEM IS COMPLETED, TESTED, AND

ACCEPTED BY THE COR, IT SHALL BE PLACED IN SERVICE AND

CONNECTED TO THE STATION FIRE ALARM SYSTEM. REMOVE TAGS FROM

NEW EQUIPMENT AND TAG THE EXISTING EQUIPMENT "NOT IN SERVICE"

UNTIL REMOVED FROM THE BUILDING. REFERENCE THE SPECIFICATIONS

FOR FURTHER DETAIL.

REFER TO PLAN DRAWINGS AND PROJECT DOCUMENTS FOR

APPROXIMATE FIRE ALARM SYSTEM QUANTITIES AND LOCATIONS, NOT ALL

SITE CONDITIONS ARE SHOWN. FIRE ALARM CONTRACTOR SHALL VISIT

JOB SITE WITH ALL PROJECT DOCUMENTS PRIOR TO BID TO BECOME

FAMILIAR WITH PROJECT DESIGN, INSTALLATION, TESTING AND

COMMISSIONING REQUIREMENTS, SITE CONDITIONS FOR NEW SYSTEM

INSTALLATION, IN ORDER TO PROVIDE A COMPREHENSIVE AND COMPLETE

BID, CODE COMPLIANT SYSTEM DESIGN, INSTALLATION, TESTING,

COMMISSIONING AND APPROVAL.

CONTRACTOR SHALL SUBMIT COMPLETE BATTERY CALCULATIONS,

VOLTAGE DROP CALCULATIONS, MATERIAL DATA SHEETS, AND SHOP

DRAWINGS TO OWNER'S TECHNICAL REPRESENTATIVE FOR REVIEW

PRIOR TO COMMENCING FABRICATION AND INSTALLATION. FAILURE TO

COMPLY IS AT THE RISK OF THE CONTRACTOR.

FIRE ALARM FLOOR PLANS AND RISER DIAGRAM ARE DIAGRAMMATIC AND

NOT INTENDED TO SHOW EACH AND EVERY COMPONENT, DEVICE,

APPLIANCE, ETC. CONDUIT PATHWAYS AND INTERCONNECTIONS SHALL BE

DETERMINED BY THE BUILDING FEATURES, NFPA 70, NFPA 72, SYSTEM

MANUFACTURER REQUIREMENTS AND RECOMMENDATIONS.

FIRE ALARM SIGNALS AND EMERGENCY COMMUNICATIONS SHALL TAKE

PRECEDENCE OVER ALL OTHER SIGNALS, SUCH AS BUT NOT LIMITED TO

PUBLIC ADDRESS SYSTEMS.

CONTRACTOR SHALL PROVIDE ALL NECESSARY AND REQUIRED SYSTEM

PROGRAMMING TO MEET THE DESIGN INTENT AND CODE COMPLIANCE.

FIRE ALARM NOTIFICATION APPLIANCES SHALL BE 15 CANDELA UNLESS

OTHERWISE NOTED.

ALL NOTIFICATION APPLIANCES CIRCUITS (NAC) SHALL PERFORM TO

CLASS "B" AS DEFINED BY NFPA 70 AND NFPA 72.

ALL SIGNALING LINE CIRCUITS (SLC) SHALL PERFORM TO CLASS "B" AS

DEFINED BY NFPA 70 AND NFPA 72.

ALL INDICATING DEVICE CIRCUITS SHALL PERFORM TO CLASS "B" AS

DEFINED BY NFPA 70 AND NFPA 72.

THE INSTALLATION OF WIRING BETWEEN THE FACP AND RELAY MODULES

OR APPLIANCES SHALL PERFORM TO CLASS "B" AS DEFINED BY NFPA 70

AND NFPA 72.

FIRE ALARM MANUAL PULL STATIONS AT DOOR OPENINGS SHALL BE

WITHIN 5' - 0" HORIZONTALLY OF THE DOOR OPENING.

ALL CONDUCTORS FOR THE FIRE ALARM SYSTEM SHALL BE INSTALLED IN

CONDUIT AND IN ACCORDANCE WITH NFPA 70. THE CONDUCTORS SHALL

NOT BE INSTALLED WITH CONDUCTORS OF LIGHTING OR POWER

SYSTEMS. THE SUM OF THE CROSS-AREA OF INDIVIDUAL CONDUCTORS

SHALL NOT EXCEED 40% OF THE INTERIOR CROSS SECTION OF THE

CONDUIT. ALL FIRE ALARM SYSTEM CONDUIT SHALL NOT BE LESS THAN

3/4".

WALL MOUNTED FIRE ALARM DEVICES IN UNFINISHED AREAS MAY BE

SURFACED MOUNTED, THE CONDUIT MAY BE INSTALLED EXPOSED ON

WALLS AND ON CEILINGS.

IN FINISHED AREAS, WALL MOUNTED DEVICES SHALL BE FLUSH MOUNTED.

THE CONDUIT SHALL BE INSTALLED CONCEALED IN THE WALLS AND

CEILINGS UNLESS REFERENCED AS CEILING MOUNTED.

ALL NEW CONDUIT IS TO BE FACTORY FINISHED RED OR PAINTED RED

THROUGHOUT THE SYSTEM, FOR BOTH EXPOSED AND CONCEALED

CONDUIT.

ELECTRICAL AND FIRE ALARM CONTRACTORS SHALL COORDINATE WITH

FIRE ALARM VENDOR FOR SYSTEM OPERATING INSTRUCTIONS AND

WIRING DIAGRAMS.

CONTRACTOR SHALL PROVIDE PATHWAY SURVIVABILITY OF LEVEL 1.

1.

2.

3.

4.

5.

6.

7.

8.

9.

10.

11.

12.

13.

14.

15.

16.

17.

18.

19.

20.

21.

FIRE ALARM NOTES

FIRE ALARM DUCT MOUNTED SMOKE DETECTOR

MANUAL FIRE ALARM PULL STATION, MOUNT 42" - 48" AFF TO

TOP OF HANDLE

VALVE SUPERVISORY SWITCH; TO REMAIN AND BE

CONNECTED TO NEW FIRE ALARM SYSTEM

WATER FLOW DETECTOR/SWITCH; TO REMAIN AND

BE CONNECTED TO NEW FIRE ALARM SYSTEM

FIRE ALARM CONTROL PANEL

NOTIFICATION APPLIANCE BOOSTER PANEL

FIRE ALARM ANNUNCIATOR

SMOKE DETECTOR - PHOTOELECTRIC

ER= ELEVATOR RECALL

R=DOOR RELEASE

ALARM INDICATING AND REMOTE TEST SWITCH;

MOUNT IN AN ACCESSIBLE LOCATION

FACP

NAC

ANN

F

FIRE ALARM CLEAR VISUAL STROBE AND SPEAKER. WALL

MOUNT AT 80" AFF TO BOTTOM OF LENS OR 6" BELOW

CEILING, WHICHEVER IS LOWER AND NOT GREATER THAN 96".

C = CEILING MOUNTED DEVICE.

WP = WEATHERPROOF

C/WP

S

S

HEAT DETECTOR

ER= ELEVATOR RECALL

ST=SHUNT TRIP

FIRE ALARM SPEAKER. WALL MOUNT AT 80" AFF TO TOP OF

DEVICE OR 6" BELOW CEILING, WHICHEVER IS LOWER AND NOT

GREATER THAN 96".

C = CEILING MOUNTED DEVICE.

S C

FIRE ALARM LEGEND

RTS

VS

WF

FIRE ALARM CLEAR VISUAL STROBE. WALL MOUNT AT 80" AFF

TO BOTTOM OF LENS OR 6" BELOW CEILING, WHICHEVER IS

LOWER AND NOT GREATER THAN 96"

PROJECT SCOPE INCLUDES THE FOLLOWING: FULL REPLACEMENT OF

THE EXISTING FIRE ALARM SYSTEM IN A FACILITY. DETECTION

DEVICES, WIRING, NOTIFICATION APPLIANCES, ANNUNCIATORS, FIRE

ALARM PANELS, POWER SUPPLIES, AREA SMOKE DETECTORS, DUCT

DETECTORS, HEAT DETECTORS, ELEVATOR RECALL INITIATION

DEVICES, ETC. WILL BE REPLACED IN THEIR ENTIRETY; WITH THE

EXCEPTION OF THOSE LISTED IN SCOPE OF WORK NOTE 11. THE

PROJECT WILL BE PHASED TO ACCOMMODATE THE ACTIVE FACILITY

AND TO MINIMIZE SYSTEM DOWNTIME. THE NEW FIRE ALARM SYSTEM

COMPONENTS WILL BE INSTALLED AND BROUGHT ONLINE PRIOR TO

THE REMOVAL OF THE EXISTING COMPONENTS.

ALL PHASING SHALL BE DETERMINED BY THE CONTRACTOR WITH

GUIDANCE FROM THE CONTRACTING OFFICER'S REPRESENTATIVE/

USER.

THE NEW SYSTEM COMPONENTS WILL BE INSTALLED TO MEET THE

CURRENT EDITION OF NFPA 72, & NFPA 101.

DEMOLITION: THE EXISTING FIRE ALARM EQUIPMENT WILL BE

REMOVED IN A PHASED PROCESS OVER THE COURSE OF THE

PROJECT AS THE NEW EQUIPMENT IS BROUGHT ONLINE. DUE TO THE

PHASING, SOME MAIN INFRASTRUCTURE EQUIPMENT WILL NEED TO

BE ACTIVE FROM THE START OF THE PROJECT (NEW FIBER LOOP,

NEW DACT, FACP, ETC.). CEILINGS, WALLS, AND FLOORS THAT

CONDUIT IS CURRENTLY PASSING THROUGH AND WALLS AND CEILING

THAT DEVICES AND APPLIANCES ARE CURRENTLY ATTACHED TO, WILL

BE IMPACTED DURING DEMOLITION AND WILL REQUIRE FILLING AND

PATCHING ON A CASE BY CASE BASIS. WALLS, CEILING, AND FLOORS

WILL BE REPAIRED TO MATCH THE EXISTING CONSTRUCTION AND/OR

FIRE/SMOKE RATINGS AS APPLICABLE.

AREAS WHERE SMOKE DETECTION IS CURRENTLY INSTALLED AND NO

LONGER REQUIRED PER CURRENT REQUIREMENTS WILL BE REMOVED

AND WILL NOT BE REINSTALLED.

NEW NOTIFICATION APPLIANCES SHALL BE ADDED TO PROVIDE

COMPLETE AND CODE COMPLIANT OCCUPANT NOTIFICATION

THROUGHOUT THE FACILITY.

THE EXISTING FIRE ALARM ZONES SHALL BE MATCHED FOR THE NEW

SYSTEM. ADD ADDITIONAL DEVICES TO THE EXISTING ZONES AS

NEEDED.

ELECTRICAL POWER FEEDS THAT CURRENTLY SUPPLIES THE FIRE

ALARM SYSTEMS WILL BE RE-USED FOR NEW FIRE ALARM PANELS.

ALL FIRE ALARM CONTROL PANELS SHALL BE REPLACED WITH NEW

ADDRESSABLE FIRE ALARM CONTROL PANELS THAT ARE COMPATIBLE

WITH EXISTING FIRE ALARM RECEIVING EQUIPMENT.

NEW FIRE ALARM CONTROL PANELS SHALL BE REPORT TO THE

ASSOCIATED FIRE ALARM RECEIVING STATION VIA EXISTING FIBER

OPTIC LINE. CONTRACTOR IS RESPONSIBLE FOR CONNECTING FIRE

ALARM CONTROL PANELS TO THE EXISTING FIBER LOCATED IN EACH

BUILDING. THE CONTRACTOR SHALL COORDINATE WHICH CENTRAL

RECEIVING LOCATION EACH PANEL REPORTS TO PRIOR TO START OF

INSTALLATION/ PROGRAMMING.

THE EXISTING RELAYS FOR FACP CONNECTION TO SMOKE CONTROL,

FIRE SUPPRESSION SYSTEMS, HVAC SHUTDOWN, GAS SHUTOFF, AND

SPRINKLER MONITORING DEVICES ARE SIEMENS TRI-R AND TRI-60R

DEVICES. (APPROXIMATELY 825 RELAYS). IF NEW SIEMENES PANELS

ARE UTILIZED, RELAYS MAY BE REUSED AND CONNECTED TO NEW

FIRE ALARM CONTROL PANELS. WHERE OTHER MANUFACTURE FACPS

ARE UTILIZED ALL EXISTING SIEMENS RELAYS MUST BE REMOVED AND

REPLACED WITH NEW INTELLIGENT INITIATING DEVICES INTERFACE

MODULES COMPATIBLE WITH THAT SELECTED SYSTEM.

1.

2.

3.

4.

5.

6.

7.

8.

9.

10.

11.

SCOPE OF WORK

CONTROL MODULECM

FIRE ALARM CLEAR STROBE. CEILING MOUNTED.

FIRE ALARM CONTRACTOR SHALL PROVIDE POWER PANEL

INFORMATION, BREAKER LOCKING AND IDENTIFICATION

REQUIREMENTS IN ACCORDANCE WITH NFPA 70 AND 72

REQUIREMENTS.

THE FIRE ALARM SYSTEM SHALL NOT BE COMBINED WITH ANY

OTHER BUILDING SYSTEM, SUCH AS BUT NOT LIMITED TO,

AUTOMATION, ENERGY, SECURITY, ETC.

REFER TO FIRE ALARM RELATED SPECIFICATION SECTIONS: 28 05

00, 28 05 13, 28 05 26, 28 05 29, & 28 31 00 FOR ADDITIONAL

REQUIREMENTS AND INFORMATION.

COORDINATION LOCATION OF ALL NEW FIRE ALARM APPLIANCES

WITH EXISTING BUILDING CONDITIONS.

NEW DUCT SMOKE DETECTORS SHALL BE PROVIDED IN SUPPLY

AIR SYSTEMS WITH A DESIGN CAPACITY GREATER THAT 2,000-CFM.

ACCESS TO DETECTORS SHALL BE PROVIDED FOR INSPECTION

AND MAINTENANCE PURPOSES. ACTIVATION OF THE DUCT

DETECTOR SYSTEM SHALL SHUT DOWN ALL OPERATIONAL

CAPABILITIES OF THE AFFECTED UNIT. COORDINATE LOCATION OF

ALL NEW REPLACED DUCT DETECTORS WITH EXISTING DETECTOR

LOCATIONS. DUCT SMOKE SENSORS SHALL BE IN ACCORDANCE

WITH NFPA 72, AND INTERNATIONAL MECHANICAL CODE.

ALL DUCT DETECTORS SHALL BE PROVIDED WITH REMOVE STATUS

INDICATION. PROVIDE INDICATING LAMP FOR ALL CONCEALED

DETECTORS.

INSTALL SMOKE DETECTORS NO CLOSER THAN 3'-0" TO HVAC AIR

SUPPLY DIFFUSERS.

22.

23.

24.

25.

26.

27.

28.

FIRE ALARM NOTES CONT.

MONITOR MODULEMM

1 2 3 4 5

A

B

C

D

SHEET ID

P a rk w a y L a n e

S u it e

P e a c h tr e e C o rn e rs

G

A

P h o n e

-7

F a x

(6

-7

S

IZ

E

A N

S I D

F

IL

E N

A M

E

S U

B M

IT

T

E D

B Y

C H

E C

K E

D B

Y

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

IS

S

U E

D A

T E

S O

L

IC

IT

A

T

IO

N N

O

C O

N T

R A

C T

N O

F

IL

E N

U M

B E

R

Copyright © 2020 by Pond & Company. All rights reserved. No copying or duplication of these documents is allowed without the express written agreement of Pond & Company.

ORIGINAL SHEET SIZE 22" X 34"

N D

S

J K

C

B T

H

C A

D

J O

B N

O

/2

/2

:5 :1

P

M B

IM

/1

F

C I C o le m a n /1

F

C I_

C o le m a n F

P v .r v t

F-001

100% BID SET

F

IR

E A

L A

R M

G E

N E

R A

L N

O T

E S

L

E G

E N

D

N

E

T

H T

E R

R A

C E

C

O L E

M A

N

F L

F B

O P

F

C C

C O

L E

M A

N F

IR

E

A L A

R M

R E

P L A

C E

M E

N T

M A

R K

D E

S C

R

IP

T I O

N D

A T

E

F

B O

P C

O M

M E

N T

S .2

.2

O

W N

E R

R E

V

IS

IO

N

S .2

.2

Sheets
F-001 - FIRE ALARM GENERAL NOTES & LEGEND

File details come from the government source that posted it. Updated .