Salient Characteristics Special Order S20028
DATALOGGERS AND PRESSURE SENSORS
SALIENT CHARACTERISTICS:
15 EA, Water Level Datalogger:
1. Shall be calibrated by manufacturer.
2. Shall be capable of Ethernet, USB, CS I/O, RS-232, CPI, RS-485, and SDI-12 communications.
3. Shall have ±5 V input limits.
4. Shall have 24-bit Analog-to-Digital Converter or better.
5. Shall have a 3-year warranty at least.
6. Shall have accuracy of ±0.06% of measurement plus offset at -40° to +70°C or better.
7. Shall have active current drain up to 67 mA at 20 Hz.
8. Shall have at least 4 MB static random-access memory plus at least 72 MB flash.
9. Shall have at least sixteen (16) pulse counters.
10. Shall have at least sixteen (16) terminals configurable for digital input and output with the ability configure terminals in pairs for 5 V or 3.3 V logic.
11. Shall have at least twelve (12) configured inputs for analog or digital functions.
12. Shall have at least two (2) switched 12 Volt terminals.
13. Shall have microSD data storage slot.
14. Shall have operating temperature range of -40° to +70°C.
15. Shall not have radios.
16. Shall run up to 18 Vdc.
10 EA, Water Level Datalogger with Radios:
17. Shall be calibrated by manufacturer.
18. Shall be capable of Ethernet, USB, CS I/O, RS-232, CPI, RS-485, and SDI-12 communications.
19. Shall have ±5 V input limits.
20. Shall have 24-bit Analog-to-Digital Converter or better.
21. Shall have a 3-year warranty at least.
22. Shall have accuracy of ±0.06% of measurement plus offset at -40° to +70°C or better.
23. Shall have active current drain up to 67 mA at 20 Hz.
24. Shall have at least 4 MB static random-access memory plus at least 72 MB flash.
25. Shall have at least sixteen (16) pulse counters.
26. Shall have at least sixteen (16) terminals configurable for digital input and output with the ability configure terminals in pairs for 5 V or 3.3 V logic.
27. Shall have at least twelve (12) configured inputs for analog or digital functions.
28. Shall have at least two (2) switched 12 Volt terminals.
29. Shall have microSD data storage slot.
30. Shall have operating temperature range of -40° to +70°C.
31. Shall run up to 18 Vdc.
32. Shall include 900MHz Spread Spectrum Radio.
a. Shall be 1W, 900MHz Frequency Hopping Spread Spectrum (FHSS) radio.
b. Shall be capable of frequency from 902 to 928 MHz.
c. Shall have be capable of RS-232, CS I/O, and USB communications.
d. Shall run on up to 16 Vdc.
20 EA, Pressure Transducer with 30ft Cable:
1. Shall have accuracy at 0.05% full-scale-range or better.
2. Shall be capable of measuring up to 20.4 meters (67 feet) depths and up to 29 pounds per square in gauge (200 kilopascal).
3. Shall take measurements in less than 2 seconds.
4. Shall have SDI-12 and RS-232 output.
5. Shall be capable of detecting 0.0035% full scale of change in water-level.
6. Shall be capable of detecting 0.006°C of change in temperature.
7. Shall have operating temperature range from 0° to 60°C.
8. Shall be capable of measuring with in ±0.2°C of the actual temperature.
9. Shall be capable of withstanding 2 times the pressure range without compromising subsequent measurements.
10. Shall have housing that allows for use in fresh and saltwater.
11. Shall have diameter no larger than 22 mm.
12. Shall have Hastelloy element.
13. Shall have 30-foot cable.
5 EA, Pressure Transducer with 50ft Cable:
14. Shall have accuracy at 0.05% full-scale-range or better.
15. Shall be capable of measuring up to 20.4 meters (67 feet) depths and up to 29 pounds per square in gauge (200 kilopascal).
16. Shall take measurements in less than 2 seconds.
17. Shall have SDI-12 and RS-232 output.
18. Shall be capable of detecting 0.0035% full scale of change in water-level.
19. Shall be capable of detecting 0.006°C of change in temperature.
20. Shall have operating temperature range from 0° to 60°C.
21. Shall be capable of measuring with in ±0.2°C of the actual temperature.
22. Shall be capable of withstanding 2 times the pressure range without compromising subsequent measurements.
23. Shall have housing that allows for use in fresh and saltwater.
24. Shall have diameter no larger than 22 mm.
25. Shall have Hastelloy element.
26. Shall have 50-foot cable.
5 EA, Pressure Transducer with 100ft Cable:
27. Shall have accuracy at 0.05% full-scale-range or better.
28. Shall be capable of measuring up to 20.4 meters (67 feet) depths and up to 29 pounds per square in gauge (200 kilopascal).
29. Shall take measurements in less than 2 seconds.
30. Shall have SDI-12 and RS-232 output.
31. Shall be capable of detecting 0.0035% full scale of change in water-level.
32. Shall be capable of detecting 0.006°C of change in temperature.
33. Shall have operating temperature range from 0° to 60°C.
34. Shall be capable of measuring with in ±0.2°C of the actual temperature.
35. Shall be capable of withstanding 2 times the pressure range without compromising subsequent measurements.
36. Shall have housing that allows for use in fresh and saltwater.
37. Shall have diameter no larger than 22 mm.
38. Shall have Hastelloy element.
39. Shall have 100-foot cable.