Sol_140FS324R0012_Amd_0001.pdf

PDF 125 KB Posted

Attached to
2 Fire Engine Pumps, NZVF NWR, NV Federal contract opportunity
Solicitation number
140FS324R0012
Issued by
Department of the Interior Fish and Wildlife Service

About this file

This document is an amendment to a solicitation for a federal contract opportunity. The U.S. Fish and Wildlife Service is issuing a Request for Quotes (RFQ) for the procurement of 2 - Type 6 Wildland Fire Light Engine Pump Packages for the Nevada Zone Fire Management Office. The solicitation is a 100% small business set-aside with a NAICS code of 336120 (Heavy Duty Truck Manufacturing) and a size standard of 1,500 employees.

The amendment extends the closing date for quotes to July 5, 2024 at 2:00 pm EST and addresses concerns raised by industry. Key details include the required chassis specifications (2024 F-550 crew cab, 60-inch cab to axle, 4x4 diesel, white), the need for a direct injection class A foam system, and the preferred configuration for emergency lights (red/white in every other zone). The anticipated period of performance is contract award to October 1, 2025. Award will be made to the responsible source that submits the lowest priced, technically acceptable offer.

View the file

Other files for this federal contract opportunity

Other files attached to 2 Fire Engine Pumps, NZVF NWR, NV, newest first.
File Type Posted
Sol_140FS324R0012_Amd_0003.pdf PDF
Sol_140FS324R0012_Amd_0002.pdf PDF
Attachment_2-_Specifications_rev2_0002.pdf PDF
Attachment_2-_Specifications_rev1_0001.pdf PDF
Attachment_3-Quote_Schedule.docx DOCX document
Attachment_4-_Past_Performance_Data_Document.docx DOCX document
Attachment_2-_Specifications.pdf PDF
Attachment_1-Solicitation-provisions_and_clauses-_140FS324R0012.docx DOCX document

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

(x)

140FS324R0012

x x copies of the amendment; (b) By acknowledging receipt of this amendment on each copy of the offer submitted ; or (c) By separate letter or electronic communication which includes a reference to the solicitation and amendment numbers. FAILURE OF YOUR ACKNOWLEDGEMENT TO BE

RECEIVED AT THE PLACE DESIGNATED FOR THE RECEIPT OF OFFERS PRIOR TO THE HOUR AND DATE SPECIFIED MAY RESULT IN REJECTION OF YOUR

OFFER. If by virtue of this amendment you desire to change an offer already submitted , such change may be made by letter or electronic communication, provided each letter or electronic communication makes reference to the solicitation and this amendment, and is received prior to the opening hour and date specified.

x

FS3

Falls Church VA 22041 5275 Leesburg Pike FWS SAT Team 3 FWS SAT Team 3

06/20/20240001

13. THIS ITEM ONLY APPLIES TO MODIFICATION OF CONTRACTS/ORDERS. IT MODIFIES THE CONTRACT/ORDER NO. AS DESCRIBED IN ITEM 14.

12. ACCOUNTING AND APPROPRIATION DATA (If required) is not extended.is extended, Items 8 and 15, and returning

Offers must acknowledge receipt of this amendment prior to the hour and date specified in the solicitation or as amended , by one of the following methods: (a) By completing

The above numbered solicitation is amended as set forth in Item 14. The hour and date specified for receipt of Offers

11. THIS ITEM ONLY APPLIES TO AMENDMENTS OF SOLICITATIONS

FACILITY CODE CODE

10B. DATED (SEE ITEM 13)

10A. MODIFICATION OF CONTRACT/ORDER NO.

9B. DATED (SEE ITEM 11)

9A. AMENDMENT OF SOLICITATION NO.

CODE

8. NAME AND ADDRESS OF CONTRACTOR (No., street, county, State and ZIP Code)

7. ADMINISTERED BY (If other than Item 6)CODE 6. ISSUED BY

PAGE OF PAGES

4. REQUISITION/PURCHASE REQ. NO.3. EFFECTIVE DATE2. AMENDMENT/MODIFICATION NO. 5. PROJECT NO. (If applicable)

1. CONTRACT ID CODE

AMENDMENT OF SOLICITATION/MODIFICATION OF CONTRACT

06/20/2024

CHECK ONE A. THIS CHANGE ORDER IS ISSUED PURSUANT TO: (Specify authority) THE CHANGES SET FORTH IN ITEM 14 ARE MADE IN THE CONTRACT

B. THE ABOVE NUMBERED CONTRACT/ORDER IS MODIFIED TO REFLECT THE ADMINISTRATIVE CHANGES (such as changes in paying office, C. THIS SUPPLEMENTAL AGREEMENT IS ENTERED INTO PURSUANT TO AUTHORITY OF:

D. OTHER (Specify type of modification and authority) appropriation data, etc.) SET FORTH IN ITEM 14, PURSUANT TO THE AUTHORITY OF FAR 43.103(b).

E. IMPORTANT: Contractor is not is required to sign this document and return __________________ copies to the issuing office.

ORDER NO. IN ITEM 10A.

14. DESCRIPTION OF AMENDMENT/MODIFICATION (Organized by UCF section headings, including solicitation/contract subject matter where feasible.)

Amendment 0001 is necessary to address concerns posed from industry. Closing extended to 05

July 2024 at 2:00 pm est.

All other terms and conditions remain unchanged.

Type 6 Wildland Fire Light Engine Pump Package Build and Install

Tech POC: Louis Prevatke (928) 581-6011

Alt POC: Leanne Abel 702-275-3792

Contract POC: Fred Riley, Fred_riley@fws.gov

16A. NAME AND TITLE OF CONTRACTING OFFICER (Type or print)15A. NAME AND TITLE OF SIGNER (Type or print)

15C. DATE SIGNED 16B. UNITED STATES OF AMERICA 15B. CONTRACTOR/OFFEROR 16C. DATE SIGNED

(Signature of person authorized to sign) (Signature of Contracting Officer)

Todd Annes

STANDARD FORM 30 (REV. 11/2016)

Prescribed by GSA FAR (48 CFR) 53.243

Previous edition unusable

Except as provided herein, all terms and conditions of the document referenced in Item 9 A or 10A, as heretofore changed, remains unchanged and in full force and effect .

Type 6 Wildland Fire Light Engine Pump Package Build and Install

Questions and Answers

Question 1: What are Ford chassis specifications desired (Cab size, cab to axle length, fuel type, color)?

Answer 1: The Chassis is a 2024 F-550 crew cab, 60inch cab to axle length, 4x4, diesel, white.

Question 2: Anywhere specific for the hose reel to be mounted?

Answer 2: The hose reel should be mounted on the pump package where it is accessible and easy to use from either side of the vehicle.

Question 3: What is the body color and "accent color" requested?

Answer 3: The body Color is white, and the accent color is white as well.

Question 4: Any stripe or lettering?

Answer 4: No striping or lettering.

Question 5: Any specific desired foam system?

Question 5: Any direct injection class A foam system will work with a wildland fire pump's lower water flow levels. Depending on the pump used for the build, this may be as low as 5 GPM and as high as 100

GPM.

Question 6: Red/white emergency lights listed: does this mean split/duo light heads or red/white in every other zone around the apparatus?

Answer 6: I think either one will work for our application. I would lean towards red/white in every other zone since I assume it will be cheaper.

Question 7: Delivery date of October 1, 2025 - Is this date flexible?

Answer 7: Yes.

Question 8: Do you know if it would be possible to get a reference picture of their current apparatus to see how the compartment(s) layout is?

Answer 8: We do not have a picture of our current apparatus. Our current engine is nothing like the specs we are asking for and would not provide useful information.

File details come from the government source that posted it. Updated .