B09__AMEND_2_Q_A_0002.pdf
PDF 389 KB Posted
- Attached to
- Adjustable Tables Federal contract opportunity
- Solicitation number
- 140A2323Q0256
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| Sol_140A2323Q0256_Amd_0002.pdf | ||
| Sol_140A2323Q0256_Amd_0001.pdf | ||
| Sol_140A2323Q0256.pdf |
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Q&A – 140A2323Q0256
Are all stations to be height adjustable or only the 2 at the end?
Response: All stations need to be height adjustable
Is there any sort of electrical needed?
Response: Yes If so, is it to be hardwired or plug and play?
Response: Each table has a built-in power strip that will then be plugged into the wall.
Each table should have 6 outlets included.
Are there any dividers needed between stations?
Response: No
Do you have a product code for the Haworth / Intuity units?
Response:
EUEH-0087-3, Belong, In-Feed Harness 87 inL, 3 Cir (quantity 1) EUEJ-0028-3, Belong, Jumper, Conduit 28in.L, 3 Cir (qualtity 4) EUEK-0042-3S, Retrofit kit, Power, Utitility Tray 42 in. L, 3 Cir, 332 (quantity 5) EUER-153P-GSOS, Triplex Receptacle, 15 Amp,332, CM, TR-E Smoke GRD A (quantity 4) TABC-0046-R, Planes, Bench Stretcher Cover, 46", Rt, TR-E SMOKE GRD A (quantity 5) TA01-BSFD-D, Plance, Hab, Base Feed Cover, Ds, Tr-E Smoke GRD A (quantity 1) TA01-HBTT-M, Planes, Hab, Base Feed Cover, ds, TR-E Smoke GRD A (quantity 4) TLRA-2446-LISNHE, Planes, LT, Bench, Rt, 24"X46", Lam, Eb3, Std, Co:None, Hat, Bench, Eadj1ss, H-AK Chalk GrdA, HP-AK Chalk GRD A, TR-E SMOKE GRD A (quantity 5)
Confirming no chairs are required.
Response: No
Is the bid for 6 Haworth double-sided hop bench work surfaces OR 5 Intuity double-sided benching units. Or is the bid for both?
Response: 6 Haworth double-sided hop bench worksurfaces.
Is this delivery only?
Response: Yes
At delivery location is there loading dock access?
Response: Yes
I would like to know if you would like these tables to be quoted with undermounted power that would be hard-wired to the school’s power, and if so, would that power be coming from the wall, the ceiling, or the floor?
Response: These are quoted with 6 outlets that will plug into a wall outlet. NOT hardwired to the school's power.
Is this only for the tables, or is this to include a chair for each station as well?
Response: These are ESPORTS Bench Worksurfaces, no chairs.
Is there to be a divider to separate the two sides, or should the center space be left open?
Response: Per the design of the worksurfaces there is no divider, there is no center space.
File details come from the government source that posted it. Updated .