AMENDMENT 0004.docx

DOCX document 207 KB Posted

Attached to
Liquid Nitrogen Supply & Service Federal contract opportunity
Solicitation number
1333ND23QNB680322
Issued by
Department of Commerce National Institute of Standards and Technology

About this file

This amendment provides responses to questions regarding solicitation number 1333ND23QNB680322 for liquid nitrogen supply and service. The government will award one contract to supply liquid nitrogen meeting specified purity levels of 99.9994% for Gaithersburg, MD, 99.999% for Boulder, CO, and 99.9994% for Charleston, SC. Acceptable trace levels are 0.5 ppm oxygen and 0.5-1 ppm water depending on location. Hydrogen demonstration may occur quarterly with additional testing on demand. A tolerance of +/- 1 ppm on all measures is allowable.

View the file

Other files for this federal contract opportunity

Other files attached to Liquid Nitrogen Supply & Service, newest first.
File Type Posted
AMENDMENT 0003.docx DOCX document
Site Visit.docx DOCX document
Combined Synopsis-Sol.docx DOCX document
1333ND23QNB680322.pdf PDF

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

AMENDMENT 0004

Purpose: Provide Government Response to Submitted Questions RFQ Number: 1333ND23QNB680322 Project: Liquid Nitrogen Supply & Services Date: 08/14/23

The purpose of amendment 0001 is to provide the Government response to submitted questions.

Question 1: What is the acceptable range for trace O2 and H20 in the LN2 deliveries?

Response 1: In accordance with the Statement of Work which is attached to the SF1449 (page 16); the tables below identify the acceptable range for trace O2 and H20 in the LN2 deliveries:

LIQUID NITROGEN SPECIFICATIONS

1. Gaithersburg, MD

Grade
5.4
Purity
99.9994%
Carbon Dioxide (CO2)
0.5PPM
Carbon Monoxide (CO)
2 PPM
Hydrogen (H2)
2PPM
Oxygen (O2)
0.5 PPM
Water (H20) (PPMV)
0.5 PPM
Total Hydrocarbons -Expressed as Methane (THC)
0.5 PPM
Total Specified Impurities
6 PPM

2. Boulder, CO

Grade
5.3
Purity
99.999%
Carbon Dioxide (CO2)
0.5 PPM
Carbon Monoxide (CO)
2 PPM
Hydrogen (H2)
2 PPM
Oxygen (O2)
1 PPM
Water (H20) (PPMV)
1 PPM
Total Hydrocarbons -Expressed as Methane (THC)
0.5 PPM
Total Specified Impurities
10 or less PPM

3. Charleston, SC

Grade
5.4
Purity
99.9994%
Carbon Dioxide (CO2)
0.5 PPM
Carbon Monoxide (CO)
2 PPM
Hydrogen (H2)
2 PPM
Oxygen (O2)
4 or less PPM
Water (H20) (PPMV)
0.5 PPM
Total Hydrocarbons -Expressed as Methane (THC)
0.5 PPM
Total Specified Impurities
6 PPM

Question 2: Is a tolerance of +/- 1 ppm acceptable?

Response 2: Yes.

Question 3: Is it acceptable to demonstrate the trace components of hydrogen (H2) on a quarterly basis, instead of including them in each load's Certificate of Analysis?

Response 3: Yes, demonstration of trace components of hydrogen on a quarterly basis is acceptable, plus on demand if NIST suspects a problem.

Question 4: Is NIST considering issuing more than one contract award if it is found to be of best value to the government?

Response 4: No. The Government intends to only issue one contract award for this opportunity.

END OF AMENDMENT 0001