DC Term Panel Specifications.pdf
PDF 47 KB Posted
- Attached to
- DC Remote Adapter - RFQ Federal contract opportunity
- Solicitation number
- 12760424Q176
- Issued by
- Department of Agriculture Forest Service
About this file
This document contains the technical specifications for a DC Term Panel required by the USDA Forest Service. The DC Term Panel must meet specific physical size, weight, temperature, humidity, power, and audio performance requirements. The related federal contract opportunity is a Request for Quote (RFQ) for the procurement of brand name or equal Gaitronics DC Remote Adapters for the USDA Forest Service. This is a firm-fixed-price purchase order under the NAICS code 541519. The procurement is set aside for small businesses, and only new equipment will be considered. No partial quotes will be accepted.
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| ICT Accessibility Requirements Statement.pdf | ||
| RFQ_Equipment Template Q176.pdf | ||
| Bill of Materials_WFAM_NIICD DCRemoteAdapter.xlsx | XLSX spreadsheet | |
| USDA Security Contract Language.pdf |
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
DC Term Panel Specifications
Physical size: no larger than each of the following dimensions 7.02 W × 5.3 L × 1.35 H Weight: no heavier than 4 lbs.
Temperature range: at least -30º C to 70º C Humidity: can withstand at least 95% at 50º C (non-condensing) Power input: at least 10.5 to 16 V dc and no more than 300 mA Hum and noise: Less than –45 dB below rated output Audio distortion: Less than 3% THD RX input: 32 mV ac to 4.5 V ac (nominal 300 mV ac) TX input: 32 mV ac to 800 mV ac in 560 ohms (nominal 80 mV ac) Line input: -25 to 0 dB ALC to reference (nominal –10 dBm) Line output: -15 to +10 dBm adjustable into 560 ohms (nominal –10 dBm) Maximum desk sets supported: 10 maximum (per system design) DC control current defaults: F1: 5.5 mA F2: 12.5 mA Monitor: -2.5 mA Low-current power demands during standby, startup, and active modes required