minimum_efficiency_requirements_tables_for_heating_cooling_products.pdf
PDF 86 KB Posted
- Attached to
- Chiller Replacement Federal contract opportunity
- Solicitation number
- 1232SC18R0006
About this file
Minimum Efficiency Requirements Tables for Heating and Cooling Products
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| Chiller_to_be_replaced.jpg | JPG image | |
| Sights_across_building_where_new_conduit_will_run.jpg | JPG image | |
| Distribution_panel.jpg | JPG image | |
| 4160_Switchgear_to_be_removed.jpg | JPG image | |
| Site_Visit_Sign_In.pdf | ||
| Q&A.pdf | ||
| Switchgear_next_to_chiller.jpg | JPG image | |
| Wage_Determination.pdf | ||
| Drawings.pdf | ||
| 1232SC18R0006.pdf | ||
| ARS371.pdf | ||
| Specifications.pdf | ||
| ARS372.pdf |
Show all 13
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
MINIMUM EFFICIENCY REQUIREMENTS TABLES FOR HEATING AND COOLING
PRODUCT CATEGORIES
The Federal Energy Management Program (FEMP) created tables that mirror American Society of Heating, Refrigerating and Air-Conditioning Engineers (ASHRAE) 90.1-2013 tables, which include minimum efficiency requirements for FEMP-designated and ENERGY STAR-qualified heating and cooling product categories.
Air-Source Heat Pumps (Residential), Central Air Conditioners (Residential), Geothermal Heat Pumps (Residential), and Light Commercial Heating and Cooling Equipment
Electrically Operated Unitary Heat Pumps: Minimum Efficiency Requirements
Equipment Type Size Category Heating Section
Type
Subcategory or Rating
Condition Minimum Efficiency
Air-cooled (cooling mode)
<65,000 Btu/h All
Split system
14 SEER; 11 EER;
8.2 HSPF (three
phase)
14.5 SEER; 12 EER;
8.2 HSPF (single
phase)
Single package
14 SEER; 11 EER;
8.0 HSPF (three
phase)
14 SEER; 11 EER;
8.0 HSPF (single
phase)
≥65,000 Btu/h and <135,000 Btu/h
Electric resistance (or none)
Split system and single package
11.3 EER; 11.4 IEER;
3.35 COP
≥135,000 Btu/h and <240,000 Btu/h
Electric resistance (or none)
Split system and single package
10.9 EER; 11 IEER;
3.25 COP
≥240,000 Btu/ha Electric resistance (or none)
Split system and single package 9.5 EER; 10.6 IEER
Geothermal, closed loop water-to-air
17.1 EER; 3.6 COP
(single phase)
Geothermal, open loop water-to-air 21.1 EER; 4.1 COP
(single phase) Geothermal, closed loop water-to-water
16.1; 3.1 COP (single phase)
Geothermal, open loop water-to-water
20.1; 3.5 COP (single phase)
Geothermal, DGX 16.0 EER; 3.6 COP (single phase) a Heat pumps with size equal to or greater than 240,000 Btu/h are not covered by federal purchasing requirements. Minimum efficiency presented is consistent with ASRHAE 90.1-2013.
Central Air Conditioners and Light Commercial Heating and Cooling Equipment
Electrically Operated Unitary Air Conditioners: Minimum Efficiency Requirements
Equipment Type Size Category Heating Section
Type
Subcategory or Rating Condition
Minimum Efficiency
Air conditioners, air-cooled
<65,000 Btu/h All
Split system
14.5 SEER and 12
EER (single phase)
14 SEER and 12 EER (three phase)
Single package
14 SEER and 11 EER (single phase)
14 SEER and 11 EER (three phase)
≥65,000 Btu/h and <135,000 Btu/h
Electric resistance (or none)
Split system and single package
11.7 EER and 11.8
IEER
All other Split system and single package
11.5 EER and 11.6
IEER
≥135,000 Btu/h and <240,000 Btu/h
Electric resistance (or none)
Split system and single package
11.7 EER and 11.8
IEER
All other Split system and single package
11.5 and 11.6 IEER
≥240,000 Btu/h and <760,000 Btu/ha
Electric resistance (or none)
Split system and single package
12.4 EER and 13.6
IEER
All other Split system and single package
12.2 EER and 13.4
IEER
≥760,000 Btu/ha
Electric resistance (or none)
Split system and single package
12.2 EER and 13.5
IEER
All other Split system and single package
12.0 EER and 13.3
IEER
a Air conditioners with size equal to or greater than 240,000 Btu/h are not covered by federal purchasing
Boilers (Residential) and Boilers (Commercial)
Gas- and Oil-Fired Boilers: Minimum Efficiency Requirements Equipment
Type Subcategory or
Rating Condition Size Category
(Input) Efficiency Metric Minimum Efficiency
Boilers, hot water
Gas-fired
<300,000 Btu/h AFUE 90% ≥300,000 Btu/h and ≤2,500,000 Btu/h Eta 95%
>2,500,000 Btu/h and ≤10,000,000
Btu/h Et 94%
>10,000,000 Btu/hb Ec 82%
Oil-fired
<300,000 Btu/h AFUE 87% ≥300,000 Btu/h and ≤2,500,000 Btu/h Et 85.5%
>2,500,000 Btu/h and ≤10,000,000
Btu/h Et 86%
>10,000,000 Btu/hb Ec 84%
Boilers, steam
Gas-fired <300,000 Btu/h AFUE 90%
Gas-fired (all, except natural draft)
≥300,000 Btu/h and ≤2,500,000 Btu/h Et 81%
>2,500,000 Btu/h and ≤10,000,000
Btu/h Et 83%
>10,000,000 Btu/hb Et 79%
Gas-fired, natural draft
≥300,000 Btu/h and ≤2,500,000 Btu/h Et 81%
>2,500,000 Btu/h and ≤10,000,000
Btu/h Et 83%
>10,000,000 Btu/hb Et 77%
Oil-fired
<300,000 Btu/h AFUE 87% ≥300,000 Btu/h and ≤2,500,000 Btu/h Et 84%
>2,500,000 Btu/h and ≤10,000,000
Btu/h Et 85.5%
>10,000,000 Btu/hb Et 81% a Thermal efficieny (Et) is based on Hydronics Institute, Method to Determine Efficiency of Commercial Space Heating Boilers (HI BTS-2000, Rev. 06.07).
b Boilers with input greater than 10,000,000 Btu/h are not covered by federal purchasing requirements.
Minimum efficiency presented is consistent with ASRHAE 90.1-2013 Table 6.8.1-6.
Electric Chillers, Air-Cooled and Water-Cooled
Water-Chilling Packages: Minimum Efficiency Requirements
Equipment Type Size Category Units
Minimum Efficiency Path A (Full-Load
Optimized Applications)
Path B (Part-Load Optimized
Applications)
Air-cooled <150 t EER (Btu/W)
≥10.40 FL ≥9.70 FL
≥13.69 IPLV ≥15.81 IPLV
Air-cooled ≥150 t EER (Btu/W)
≥10.50 FL ≥9.70 FL
≥14.00 IPLV ≥16.10 IPLV
Water-cooled, electrically operated positive displacement
<75 t kW/t
≤0.73 FL ≤0.78 FL
≤0.60 IPLV ≤0.50 IPLV
Water-cooled, electrically operated positive displacement
≥75 t and <150 t kW/t
≤0.72 FL ≤0.75 FL
≤0.56 IPLV ≤0.49 IPLV
Water-cooled, electrically operated positive displacement
≥150 t and <300 t kW/t
≤0.65 FL ≤0.68 FL
≤0.54 IPLV ≤0.44 IPLV
Water-cooled, electrically operated positive displacement
≥300 t and <600 t kW/t
≤0.61 FL ≤0.62 FL
≤0.52 IPLV ≤0.41 IPLV
Water-cooled, electrically operated positive displacement
≥600 t kW/t
≤0.56 FL ≤0.58 FL
≤0.50 IPLV ≤0.38 IPLV
Water-cooled, electrically operated centrifugal <150 t kW/t
≤0.61 FL ≤0.69 FL
≤0.55 IPLV ≤0.44 IPLV
Water-cooled, electrically operated centrifugal
≥150 t and <300 t kW/t
≤0.61 FL ≤0.63 FL
≤0.55 IPLV ≤0.40 IPLV
Water-cooled, electrically operated centrifugal
≥300 t and <400 t kW/t
≤0.56 FL ≤0.59 FL
≤0.52 IPLV ≤0.39 IPLV
Water-cooled, electrically operated centrifugal
≥400 t and <600 t kW/t
≤0.56 FL ≤0.58 FL
≤0.50 IPLV ≤0.38 IPLV
Water-cooled, electrically operated centrifugal ≥600 t kW/t
≤0.56 FL ≤0.58 FL
≤0.50 IPLV ≤0.38 IPLV
Electric Storage Water Heaters, Gas Storage Water Heaters, Gas Water Heaters, and Solar Water Heaters
Water-Heating Equipment: Performance Requirements
Equipment Type Size Category (Input) Subcategory or Rating Condition Performance Required
Electric storage water heaters ≤24 A and ≤250 V
Heat pump ≤55 gal EFa ≥2.0 and FHR ≥50 gal/h
Heat pump >55 gal and ≤120 gal EF ≥2.2 and FHR ≥50 gal/h
Gas storage water heaters
≤75,000 Btu/h
≥20 gal and ≤55 gal EF ≥0.67 and FHR ≥67 gal/h
>55 gal and ≤100 gal EF ≥0.77 and FHR ≥67 gal/h
>75,000 Btu/h >100 gal and ≤140 gal
TE ≥0.94 or EF ≥0.93 and SL ≤0.84 * [(input rate/800) +
100√volume)] Btu/h
Gas instantaneous water heaters
≥50,000 Btu/h and <200,000 Btu/h <4,000 (Btu/h)/gal EF ≥0.90 and GPM ≥2.5 over a 77-deg rise
≥200,000 Btu/h ≥4,000 (Btu/h)/gal TE ≥0.94 or EF ≥0.93
Solar water heaters ≤75,000 Btu/h
Electric backup SEF ≥1.8
Gas backup SEF ≥1.2 a Energy factor (EF) is an efficiency ratio of the energy supplied in heater water divided by the energy input to the water heater.
Gas Furnaces
Warm-Air Furnaces: Minimum Efficiency Requirements
Equipment Type Size Category (Input)
Subcategory or Rating Condition Minimum Efficiency
Warm-air furnace, gas fired
<225,000 Btu/h Maximum capacity ≥95.0% (U.S.
North/Canada) ≥90.0% (U.S. South)
≥225,000 Btu/ha Maximum capacity 80% Et
Warm-air furnace, oil fired
<225,000 Btu/h Maximum capacity ≥85% AFUE ≥225,000 Btu/ha Maximum capacity 81% Et a Furnaces with input equal to or greater than 225,000 Btu/h are not covered by federal purchasing
Room Air Conditioners
Electrically Operated Room Air Conditioners: Minimum Efficiency Requirements
Equipment Type Size Category (Input)
Subcategory or Rating
Condition Minimum Efficiency
Room air conditioners with louvered sides
<6,000 Btu/h - 11.2 EER and 11.0
CEER
≥6,000 Btu/h and <8,000 Btu/h - 11.2 EER and 11.0
CEER
≥8,000 Btu/h and
<14,000 Btu/h - 11.3 EER and 11.2
CEER
≥14,000 Btu/h and <20,000 Btu/h - 11.2 EER and 11.1
CEER
≥20,000 Btu/h - 9.8 EER and 9.8
CEER
Room air conditioners without louvered sides
≤8,000 Btu/h - 10.4 EER and 10.2
CEER
≥8,000 Btu/h and <20,000 Btu/h - 9.8 EER and 9.7
CEER
≥20,000 Btu/h and
<28,000 Btu/h - 9.8 EER and 9.7
CEER
≥28,000,000 Btu/h - 9.8 EER and 9.8
CEER
Room air-conditioner heat pumps with louvered sides
<20,000 Btu/h - 10.4 EER and 10.3
CEER
≥20,000 Btu/h - 9.8 EER and 9.8
CEER
Room air-conditioner heat pumps without louvered sides
<14,000 Btu/h - 9.8 EER and 9.7
CEER
≥14,000 Btu/h - 9.2 EER and 9.1
CEER
Room air conditioner, casement only All capacities - 10.0 EER and 9.9
CEER
Room air conditioner, casement slider All capacities - 10.9 EER and 10.8
CEER
MINIMUM EFFICIENCY REQUIREMENTS TABLES FOR HEATING AND COOLING PRODUCT CATEGORIES
File details come from the government source that posted it.